GLORIA

GEOMAR Library Ocean Research Information Access

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    Journal of interventional cardiology 14 (2001), S. 0 
    ISSN: 1540-8183
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: Using an Amplatzer duct occluder, 106 patients (weight 21 ± 18 kg) underwent an attempt at catheter closure of a persistently patent ductus arteriosus (PDA). Their age ranged from 22 days to 48 years. The PDA measured between 1.2 to 8.1 mm at its narrowest diameter. The device was successfully implanted in 105 patients. The immediate closure rate was 70% and gradually increased to 100% at 1 -month follow-up. There was no clinical evidence of hemolysis and no incidence of device embolization or bacterial arteritis. Doppler evaluation showed no evidence of aortic arch or pulmonary artery obstruction. The device, which is currently undergoing multicenter clinical trial in the United States, is proving to be a safe and effective device for closure of the persistently PDA. (J Interven Cardiol 2001;14:33–36)
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Pediatric cardiology 14 (1993), S. 66-66 
    ISSN: 1432-1971
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1432-1076
    Keywords: Key words Patent ductus arteriosus ; Detachable coil ; Amplatzer duct occluder
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract  Several different devices were evaluated for the percutaneous closure of patent ductus arteriosus (PDA), and important drawbacks were found in all of them. To overcome these drawbacks, both detachable Cook PDA coils and Amplatzer duct occluders (ADO) were used for the percutaneous closure of PDA. A total of 54 patients underwent transcatheter occlusion of PDA at a median age of 4.5 years (range 0.5–29 years) and at a median weight of 19.5 kg (range 6–69 kg). Three patients were adults. Detachable Cook PDA coils were used in 26 patients with a median PDA diameter of 1.7 mm (range 1.1–2.2 mm) and ADO were used in 28 patients with a median PDA diameter of 3.8 mm (range 1.9–7.5 mm). Devices were successfully implanted in all 54 patients. Complete closure was achieved in 53 of 54 patients (98% closure rate). Median fluoroscopy time was 12 min (range 4–47 min). Conclusion According to our experience, the complementary use of detachable Cook patent ductus arteriosus coils and Amplatzer duct occluders for the percutaneous closure of PDA can be recommended.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...