GLORIA

GEOMAR Library Ocean Research Information Access

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    International journal of legal medicine 76 (1975), S. 283-291 
    ISSN: 1437-1596
    Keywords: Papier- und Dünnschichtchromatographie ; Basische Arzneistoffe ; Systematische Analyse
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine , Law
    Description / Table of Contents: Zusammenfassung Im Prinzip besteht die mitgeteilte Systematik der papier- und dünnschichtchromatographischen Untersuchungen von basischen Arzneimitteln darin, daß die Lagen der Flecke einer gesuchten Substanz auf mehreren Chromatogrammen in ihrer Beziehung zu mitentwickelten 5–7 Testsubstanzen durch Zahlen verschlüsselt werden. Bei festgelegter Reihenfolge der Lösungsmittelsysteme ergeben sich durch Aneinanderreihen dieser (mit zusätzlichen Merkmalen versehenen) Zahlen für die Wirkstoffe charakteristische Kennziffern, die auch für eine große Zahl von Wirkstoffen (z.B. 300) in allen Fällen deutliche Unterschiede aufweisen, wenn die Zahl der in geeigneter Weise abgestimmten Laufmittelsysteme auf 6 erhöht wird. Die Auswertung der Kennziffern kann tabellarisch oder mit Hilfe von Lochkarten erfolgen.
    Notes: Summary The systematic approach described for investigating basic (pharmaceutical) drugs with the aid of paper and thin-layer chromatography relies on the principle that the positions of the spots created by a certain substance on various chromatograms in relation to 5 to 7 test substances and developed together with the sample are indicated by a digit code. With a pre-determined sequence of application of the solvents, code numbers are formed ba writing down these digits (supplemented by indices), which are characteristic of the components of the mixture. The code numbers are in all cases clearly distinctive even in the case of a large number of different substances (e.g. 300) if the number of appropriately chosen developing solutions is increased to 6. Evaluation of the code numbers can be carried out with tables or with the aid of punch cards.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    International journal of legal medicine 68 (1971), S. 171-179 
    ISSN: 1437-1596
    Keywords: Opium ; Haschisch ; Halluzinogene ; Harnanalyse ; Rauschmittelnachweis
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine , Law
    Description / Table of Contents: Zusammenfassung In der Arbeit sind einige in der Praxis bewährte Analysenverfahren für Opium, Haschisch und verschiedene Halluzinogene zusammengestellt, die in jedem Laboratorium durchgeführt werden können. Daneben werden die Nachweismöglichkeiten für Marihuana und LSD nach Körperpassage diskutiert.
    Notes: Summary Several well-proved analytical methods for tracing opium, hashish and various hallucinogenes, which can be applied in any laboratory are compiled in this work. In addition, the possibility of tracing marihuana and LSD after passing trough the body are discussed.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    International journal of legal medicine 72 (1973), S. 269-277 
    ISSN: 1437-1596
    Keywords: Nicotinvergiftung ; Nicotintest
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine , Law
    Description / Table of Contents: Zusammenfassung Bei einer 23 Jahre alten Berufspraktikantin sollte zur Abklärung eines Diabetes insipidus ein Nicotintest in seiner intravenösen Form durchgeführt werden. Noch während der Injektion verstarb die Patientin, ohne daß dafür zunächst eine Erklärung gefunden wurde. Die orientierende chemische Analyse im Anschluß an die Leichenöffnung ergab überraschend hohe Nicotingehalte, die auf ein Mehrfaches der tödlichen Dosis (40 bis 60 mg per os) schließen ließen. Zur genauen Bestimmung der tatsächlich zugeführten Menge wurden Tierversuche durchgeführt. Danach war eine Zufuhr von 440 mg anzunehmen. Die gerichtliche Nachprüfung ergab, daß infolge eines Denkfehlers statt der für den Nicotintest vorgesehenen 1 bis 3 mg insgesamt 0,5 ml einer 97%igen Nicotinlösung, d. h. ca. 490 mg Nicotin, intravenös injiziert worden waren. Im Hinblick auf die Toxicität des Nicotins wird empfohlen, den Nicotintest in dieser Form zu verlassen, zumal eine ganze Reihe anderer diagnostischer Möglichkeiten zur Verfügung stehen.
    Notes: Summary An intravenous nicotine test was performed on a 23-year-old female in order to diagnose a diabetes insipidus. The patient died during the injection unexplainedly. The chemical analysis performed after autopsy showed surprisingly high nicotine amounts, indicating that the lethal dose (40 to 60 mg per os) had been exceeded. Animal tests were carried out in order to determine the amount actually injected and the experimental figure arrived at was a dose of 440 mg. The inquest showed that by mistake 0.5 ml of a 97% solution of nicotine, that is a total of about 490 mg had been injected intravenously instead of the prescribed 1 to 3 mg. In view of the toxicity of nicotine, it is recommended that the nicotine test in this form be abandoned, especially since there are a number of other diagnostic tests available.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Springer
    International journal of legal medicine 98 (1987), S. 249-254 
    ISSN: 1437-1596
    Keywords: Computer, analytic toxicology ; Data management, identification ; Toxicology, computer-supported ; EDV, analytische Toxikologie ; Data-Management, Identifizierung unbekannter Fremdsubstanzen ; Toxikologie, Computereinsatz
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine , Law
    Description / Table of Contents: Zusammenfassung Die Möglichkeiten eines Personal-Computers mit installierter Datenbanksoftware in der chemisch-toxikologischen Analytik werden aufgezeigt. Es wird eine toxikologische Datenbank mit 370 basischen Wirkstoffen vorgestellt, die ohne Kenntnis einer höheren Programmiersprache erstellt wurde und als Grundlage für die Identifizierung dieser Wirkstoffe in der routinemäßigen Analytik mittels PC, DC and GC dient.
    Notes: Summary The potential applications of a personal computer with integrated database software in toxicologic analysis are discussed. A toxicologic database including 370 basic compounds, is presented that was built up without knowledge of a higher programming language and was used as a base for drug identification in normal analysis by PC, DC and GC.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Springer
    Archives of toxicology 26 (1970), S. 176-178 
    ISSN: 1432-0738
    Keywords: Chloroquine Poisoning ; Chloroquin-Vergiftung
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Zusammenfassung In den Organen eines 27jährigen Mannes, der unter akuten Intoxikationszeichen (übelkeit, Erbrechen, Bewu\tlosigkeit, Krämpfe) plötzlich verstorben war, fanden sich auf das Gesamtgewicht der Weichteile berechnet etwa 4 g Chloroquin. Besonders hoch war dabei die Wirkstoffkonzentration in der Leber.
    Notes: Summary In the organs of a 27 year old man who had died suddenly with prior symptoms of an acute intoxication (nausea, vomiting, loss of consciousness and convulsions), approximately 4 gm of chloroquine were detected, calculated on the basis of total weight of soft tissue. The concentration of the substance was particularly high in the liver.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 329 (1987), S. 490-490 
    ISSN: 1618-2650
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 260 (1972), S. 31-32 
    ISSN: 1618-2650
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...