GLORIA

GEOMAR Library Ocean Research Information Access

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
Document type
Publisher
Years
  • 1
    Publication Date: 2013-12-25
    Description: Purpose Kinetic analysis using dynamic contrast enhanced MRI to assess neovascularization of carotid plaque requires images with high spatial and temporal resolution. This work demonstrates a new three-dimensional (3D) dynamic contrast enhanced imaging sequence, which directly measures the arterial input function with high temporal resolution yet maintains the high spatial resolution required to identify areas of increased adventitial neovascularity. Theory and Methods The sequence consists of multiple rapid acquisitions of a saturation prepared dynamic 3D gradient recalled echo (GRE) sequence temporally interleaved with multiple acquisitions of a 2D slice. The saturation recovery time was adjusted to maintain signal linearity with the very different contrast agent concentrations in the 2D slice and 3D volume. The K trans maps were obtained from the 3D dynamic contrast measurements while the 2D slice was used to obtain the arterial input function. Calibration and dynamic studies are presented. Results For contrast agent concentrations up to 5 mM, a saturation recovery time for the 2D slice of 20 ms resulted in less than a 10% deviation from the desired linear response of signal intensity with contrast agent concentration. The corresponding saturation recovery time of 83 ms for the 3D volume maintained less than a 10% deviation from the linear response up to contrast agent concentrations of 2 mM while a contrast agent concentration of 5 mM had almost a 30% deviation. There was a significant improvement in signal attenuation (9 ± 3% versus 23 ± 5% at 40 cm/s) when flow compensation was added to the slice select gradients. For patient studies, volume transfer and plasma fraction maps were calculated with data from the proposed sequence. Conclusion This work demonstrated a novel sequence for 3D dynamic contrast enhanced imaging with a simultaneously acquired 2D slice that directly measures the arterial input function with high temporal resolution. Acquisition parameters can be adjusted to accommodate the full range of contrast agent concentration values to be encountered and the kinetic parameters obtained were consistent with expected values. Magn Reson Med, 2013. © 2013 Wiley Periodicals, Inc.
    Print ISSN: 0740-3194
    Electronic ISSN: 1522-2594
    Topics: Medicine
    Published by Wiley-Blackwell
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...