GLORIA

GEOMAR Library Ocean Research Information Access

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
Document type
Publisher
Years
  • 1
    Electronic Resource
    Electronic Resource
    350 Main Street , Malden , MA 02148 , USA , and 9600 Garsington Road , Oxford OX4 2DQ , UK . : Blackwell Science Inc
    Journal of cardiovascular electrophysiology 14 (2003), S. 0 
    ISSN: 1540-8167
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: Introduction: Implantable cardioverter defibrillators (ICDs) are being implanted for primary and secondary prevention of sudden death in children and young adults with congenital heart disease. Over time, ICD leads adhere to venous endothelium and endocardium. Lead removal, when necessary, often requires disruption of this fibrous tissue. Methods and Results: We retrospectively reviewed and analyzed our experience with ICD lead extraction in children and young adults with congenital heart disease. From April 1999 through January 2002, 14 patients underwent 15 lead extraction procedures to remove 21 leads (17 ICD leads and 4 pacing or sensing leads). Seven patients had surgically corrected structural heart disease (5 transposition of the great arteries with atrial switch repair and 2 corrected tetralogy of Fallot). Mean patient age at extraction was 17.9 ± 5.7 years (range 9–32), and mean duration of lead implantation was 42.0 ± 18.9 months (range 15–75). Fourteen of 15 procedures were performed for lead fracture or failure. A laser sheath was used for 20 of 21 lead extractions. Twenty of 21 leads (95%) were completely extracted. There were three instances of blood loss requiring transfusion. There were no major complications or deaths. Conclusion: Young congenital heart disease patients with an ICD are at risk for growth-related lead distortion. The use of a laser sheath is safe and effective for ICD lead extraction in congenital heart disease patients, despite coil adherence and altered anatomy. It may be advisable to avoid dual-coil leads in patients with the potential for future growth. (J Cardiovasc Electrophysiol, Vol. 14, pp. 344-349, April 2003)
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    350 Main Street , Malden , MA 02148-5018 , USA and 9600 Garsington Road , Oxford OX4 2DQ , UK . : Blackwell Science Inc
    Pacing and clinical electrophysiology 27 (2004), S. 0 
    ISSN: 1540-8159
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: The virtual electrode model predicts that pacing stimulus strength should reflect proximity of the pacing electrode to excitable myocardium, allowing pacing threshold to assess radiofrequency (RF) ablation lesions and unexcitable scar. The purpose of this study is to correlate RF lesion size with pacing threshold and electrogram (EG) amplitude change at the ablation site. In four swine (32–58 kg, 20 ventricular RF lesions were created using a 4-mm tip electrode catheters under fluoroscopic and electroanatomic guidance. Unipolar pacing threshold and bipolar and unipolar EG amplitude were measured before and after ablation and compared with lesion size measured in the fixed, serially sectioned tissue. Lesion diameter ranged from 6.4 to 19 mm and volume ranged from 29 to 1920 mm.3 Ablation increased the pacing threshold by 320%, from 0.9 ± 0.3 to 3.6 ± 2.6 mA, P 〈 0.001. The change in pacing threshold correlated with lesion volume R = 0.88, P 〈 0.001). Linear regression predicts that lesion volume (mm3) = 160 X rise in pacing threshold + 13. Ablation reduced peak to peak bipolar EG amplitude by 56%, from 2.5 ± 2.0 mV to 1.1 ± 0.6 mV (P = 0.005). Unipolar EG amplitude diminished by only 22% from 4.0 ± 1.6 to 3.2 ± 0.9 mV postablation (P = 0.005). The correlations of lesion volume with change in either bipolar R = 0.14, P = 0.6) or unipolar R = 0.18, P = 0.6) EG amplitude were poor. Pacing threshold correlates with RF ablation lesion size, consistent with the virtual electrode model. In normal myocardium, change in pacing threshold is likely to be a better marker of lesion size than electrogram amplitude. (PACE 2004; 27:933–937)
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...