GLORIA

GEOMAR Library Ocean Research Information Access

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1398-9995
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: Skin prick testing (SPT) is the standard method for diagnosing allergic sensitization but is to some extent performed differently in clinical centres across Europe. There would be advantages in harmonizing the standard panels of allergens used in different European countries, both for clinical purposes and for research, especially with increasing mobility within Europe and current trends in botany and agriculture. As well as improving diagnostic accuracy, this would allow better comparison of research findings in European allergy centres. We have compared the different SPT procedures operating in 29 allergy centres within the Global Allergy and Asthma European Network (GA2LEN). Standard SPT is performed similarly in all centres, e.g. using commercial extracts, evaluation after 15–20 min exposure with positive results defined as a wheal 〉3 mm diameter. The perennial allergens included in the standard SPT panel of inhalant allergens are largely similar (e.g. cat: pricked in all centres; dog: 26 of 29 centres and Dermatophagoides pteronyssinus: 28 of 29 centres) but the choice of pollen allergens vary considerably, reflecting different exposure and sensitization rates for regional inhalant allergens. This overview may serve as reference for the practising doctor and suggests a GA2LEN Pan-European core SPT panel.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Science, Ltd
    Allergy 57 (2002), S. 0 
    ISSN: 1398-9995
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: An increasing body of evidence shows that nerve growth factor (NGF) exerts biological activity not only on the central and peripheral nervous system, but also on the immune system thereby influencing allergic diseases and asthma.(1) NGF circulating levels are increased in patients with allergic diseases and asthma, and are related to the severity of the inflammatory process and disease. In vernal keratoconjunctivitis, NGF plasma levels correlate with the number of mast cells infiltrating the conjunctiva, and NGF mRNA is increased in nasal mucosal scrapings of patients with allergic rhinitis who have high levels of NGF in serum and nasal fluids; NGF is further increased in nasal fluids after specific allergen challenge.(2) NGF is produced and released by several modulatory and effector cells of allergic inflammation and asthma, for example T-helper 2 lymphocytes, mast cells and eosinophils.(3) NGF receptors are expressed on the conjunctival epithelium of patients with allergic conjunctivitis and the number of NGF-receptor positive cells is increased in the conjunctiva of these patients. Indeed, local administration of NGF induces fibroblast activation and healing processes of human corneal ulcers, which suggests that NGF plays a role in tissue remodelling processes occurring in asthma.(4) NGF increases airway hyperreactivity to histamine in an animal model of asthma, while anti-NGF treatment reduces airway hyperreactivity induced by ovalbumin topical challenge in the sensitized mouse.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 3
    Publication Date: 2019-05-28
    Description: An intercomparison of radiance and irradiance ocean color radiometers (the second laboratory comparison exercise—LCE-2) was organized within the frame of the European Space Agency funded project Fiducial Reference Measurements for Satellite Ocean Color (FRM4SOC) May 8–13, 2017 at Tartu Observatory, Estonia. LCE-2 consisted of three sub-tasks: (1) SI-traceable radiometric calibration of all the participating radiance and irradiance radiometers at the Tartu Observatory just before the comparisons; (2) indoor, laboratory intercomparison using stable radiance and irradiance sources in a controlled environment; (3) outdoor, field intercomparison of natural radiation sources over a natural water surface. The aim of the experiment was to provide a link in the chain of traceability from field measurements of water reflectance to the uniform SI-traceable calibration, and after calibration to verify whether di�erent instruments measuring the same object provide results consistent within the expected uncertainty limits. This paper describes the third phase of LCE-2: The results of the field experiment. The calibration of radiometers and laboratory comparison experiment are presented in a related paper of the same journal issue. Compared to the laboratory comparison, the field intercomparison has demonstrated substantially larger variability between freshly calibrated sensors, because the targets and environmental conditions during radiometric calibration were di�erent, both spectrally and spatially. Major di�erences were found for radiance sensors measuring a sunlit water target at viewing zenith angle of 139� because of the di�erent fields of view. Major di�erences were found for irradiance sensors because of imperfect cosine response of di�users. Variability between individual radiometers did depend significantly also on the type of the sensor and on the specific measurement target. Uniform SI traceable radiometric calibration ensuring fairly good consistency for indoor, laboratory measurements is insu�cient for outdoor, field measurements, mainly due to the di�erent angular variability of illumination. More stringent specifications and individual testing of radiometers for all relevant systematic e�ects (temperature, nonlinearity, spectral stray light, etc.) are needed to reduce biases between instruments and better quantify measurement uncertainties.
    Repository Name: EPIC Alfred Wegener Institut
    Type: Article , isiRev
    Format: application/pdf
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 4
    Publication Date: 2019-05-28
    Description: An intercomparison of radiance and irradiance ocean color radiometers (The Second Laboratory Comparison Exercise—LCE-2) was organized within the frame of the European Space Agency funded project Fiducial Reference Measurements for Satellite Ocean Color (FRM4SOC) May 8–13, 2017 at Tartu Observatory, Estonia. LCE-2 consisted of three sub-tasks: 1) SI-traceable radiometric calibration of all the participating radiance and irradiance radiometers at the Tartu Observatory just before the comparisons; 2) Indoor intercomparison using stable radiance and irradiance sources in controlled environment; and 3) Outdoor intercomparison of natural radiation sources over terrestrial water surface. The aim of the experiment was to provide one link in the chain of traceability from field measurements of water reflectance to the uniform SI-traceable calibration, and after calibration to verify whether di�erent instruments measuring the same object provide results consistent within the expected uncertainty limits. This paper describes the activities and results of the first two phases of LCE-2: the SI-traceable radiometric calibration and indoor intercomparison, the results of outdoor experiment are presented in a related paper of the same journal issue. The indoor experiment of the LCE-2 has proven that uniform calibration just before the use of radiometers is highly e�ective. Distinct radiometers from di�erent manufacturers operated by di�erent scientists can yield quite close radiance and irradiance results (standard deviation s 〈 1%) under defined conditions. This holds when measuring stable lamp-based targets under stationary laboratory conditions with all the radiometers uniformly calibrated against the same standards just prior to the experiment. In addition, some unification of measurement and data processing must be settled. Uncertaint of radiance and irradiance measurement under these conditions largely consists of the sensor’s calibration uncertainty and of the spread of results obtained by individual sensors measuring the same object.
    Repository Name: EPIC Alfred Wegener Institut
    Type: Article , isiRev
    Format: application/pdf
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 5
    Publication Date: 2020-02-12
    Type: info:eu-repo/semantics/article
    Format: application/pdf
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 6
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...