GLORIA

GEOMAR Library Ocean Research Information Access

feed icon rss

Ihre E-Mail wurde erfolgreich gesendet. Bitte prüfen Sie Ihren Maileingang.

Leider ist ein Fehler beim E-Mail-Versand aufgetreten. Bitte versuchen Sie es erneut.

Vorgang fortführen?

Exportieren
Filter
Publikationsart
Verlag/Herausgeber
Erscheinungszeitraum
  • 1
    ISSN: 1573-6776
    Schlagwort(e): aqueous two-phase systems ; fluorescence ; PicoGreen ; plasmid DNA
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Werkstoffwissenschaften, Fertigungsverfahren, Fertigung
    Notizen: Abstract The development of aqueous two-phase systems for plasmid purification from Escherichia coli cell lysates requires a reliable DNA quantitation method. Plasmid DNA was quantified by fluorescence using PicoGreen nucleic acid stain. Linearity was obtained up to 40 ng plasmid ml−1. Two polyethyleneglycol (PEG)/salt systems were studied, PEG 600/K2HPO4 and PEG 300/K2HPO4. The average plasmid recovery was 41% in the bottom phase of the first system and 35% in the top phase of the second system. This method has proved to be simple and reproducible.
    Materialart: Digitale Medien
    Standort Signatur Einschränkungen Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 2
    Digitale Medien
    Digitale Medien
    Springer
    Bioseparation 9 (2000), S. 1-6 
    ISSN: 1573-8272
    Schlagwort(e): expanded bed chromatography ; ion-exchange ; plasmid isolation
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Werkstoffwissenschaften, Fertigungsverfahren, Fertigung
    Notizen: Abstract Recent developments in gene therapy with non-viral vectors and DNA vaccination have increased the demand for large amounts of pharmaceutical-grade plasmid DNA. The high viscosity of process streams is of major concern in the purification of plasmids, since it can cause high back pressures in column operations, thus limiting the throughput. In order to avoid these high back pressures, expanded bed anion exchange chromatography was evaluated as an alternative to fixed bed chromatography. A Streamline 25 column filled with 100 ml of Streamline QXL media, was equilibrated with 0.5 M NaCl in TE (10 mM Tris, 1 mM EDTA, pH=8.0) buffer at an upward flow of 300 cmh-1, E. coli lysates (obtained from up to 3 liters of fermentation broth) were injected in the column. After washing out the unbound material, the media was allowed to sediment and the plasmid was eluted with 1 M NaCl in TE buffer at a downward flow of 120 cmh-1. Purification factors of 36±1 fold, 26±0.4 plasmid purity, and close to 100% yields were obtained when less than one settled column volume of plasmid feed was injected. However, both recovery yield and purity abruptly decreased when larger amounts were processed–values of 35±2 and 5±0.7 were obtained for the recovery yield and purity, respectively, when 250 ml of feedstock were processed. In these cases, gel clogging and expansion collapse were observed. The processing of larger volumes, thus larger plasmid quantities, was only possible by performing an isopropanol precipitation step prior to the chromatographic step. This step led to an enhancement of the purification step.
    Materialart: Digitale Medien
    Standort Signatur Einschränkungen Verfügbarkeit
    BibTip Andere fanden auch interessant ...
Schließen ⊗
Diese Webseite nutzt Cookies und das Analyse-Tool Matomo. Weitere Informationen finden Sie hier...