GLORIA

GEOMAR Library Ocean Research Information Access

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
Material
Language
  • 1
    Online Resource
    Online Resource
    Acta Physica Sinica, Chinese Physical Society and Institute of Physics, Chinese Academy of Sciences ; 2024
    In:  Acta Physica Sinica Vol. 73, No. 7 ( 2024), p. 072801-
    In: Acta Physica Sinica, Acta Physica Sinica, Chinese Physical Society and Institute of Physics, Chinese Academy of Sciences, Vol. 73, No. 7 ( 2024), p. 072801-
    Abstract: Neutron capture reaction is one of the neutron reactions and plays an important role in using reactor control rods and shell materials, designing nuclear device structures, and studying nuclear astrophysics S processes and element origins. The 4π BaF 〈 sub 〉 2 〈 /sub 〉 detection device has advantages such as high time resolution, low neutron sensitivity, and high detection efficiency, thus making it suitable for measuring neutron radiation capture reaction cross-section data. In order to fill the gap in our neutron capture reaction data in the keV energy range and improve their accuracy, the Key Laboratory of Nuclear Data at the Chinese Institute of Atomic Energy (CIAE) has established a Gamma Total Absorption Facility (GTAF), which consists of 28 hexagonal BaF 〈 sub 〉 2 〈 /sub 〉 crystals and 12 pentagonal BaF 〈 sub 〉 2 〈 /sub 〉 crystals to form a spherical shell with an external diameter of 25 cm and an internal diameter of 10 cm, covering 95.2% of the solid angles. The Back-n beam line of the Chinese Spallation Neutron Source (CSNS) is a back-streaming white beam line that covers neutron energy ranging from a few eV to several hundred MeV, making it suitable for measuring neutron capture cross-sections. The reaction cross-section data of 〈 sup 〉 197 〈 /sup 〉 Au is measured by using GTAF on the Back-n beam line. The measurement data are preliminarily background deducted through energy screening, PSD method, and crystal multiplicity screening. Subsequently, the background is analyzed and deducted based on the measurement data of 〈 sup 〉 nat 〈 /sup 〉 C and empty samples, and the yield of 〈 sup 〉 197 〈 /sup 〉 Au capture reaction is obtained. Resonance parameters are a set of parameters extracted from experimental data to describe the resonance curve, which can eliminate the influence of experimental conditions on resonance data and are more important than the cross-section obtained from experiments. The resonance energy, neutron resonance width, and gamma resonance width parameters of 〈 sup 〉 197 〈 /sup 〉 Au at 1–100 eV are fitted by using the SAMMY program. From the comparison between the resonance curves obtained from experimental measurements and the resonance parameters obtained from fitting with the ENDF/B-VIII.0 database, it can follow that the experimental measurement results are in good agreement with the database, nevertheless, there exist some differences in the resonance parameter, which may be due to the GTAF energy resolution, Back-n neutron spectrum measurement accuracy, and the experimental background deduction method. Our next work is to identify the sources of difference.
    Type of Medium: Online Resource
    ISSN: 1000-3290 , 1000-3290
    Language: Unknown
    Publisher: Acta Physica Sinica, Chinese Physical Society and Institute of Physics, Chinese Academy of Sciences
    Publication Date: 2024
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 2
    Online Resource
    Online Resource
    Acta Physica Sinica, Chinese Physical Society and Institute of Physics, Chinese Academy of Sciences ; 2021
    In:  Acta Physica Sinica Vol. 70, No. 22 ( 2021), p. 222801-
    In: Acta Physica Sinica, Acta Physica Sinica, Chinese Physical Society and Institute of Physics, Chinese Academy of Sciences, Vol. 70, No. 22 ( 2021), p. 222801-
    Abstract: The data of neutron capture cross section are very important for the research of nuclear astrophysics, advanced nuclear energy development. Owing to the limitation of neutron source and detector, the experimental data of neutron capture cross section in an energy range of 1 eV–10 keV were almost blank in China. The first Chinese gamma-ray total absorption facility has been constructed in the key laboratory of nuclear data at China institute of atomic energy, which consists of 40 BaF〈sub〉2〈/sub〉 detector units. The BaF〈sub〉2〈/sub〉 crystal shell with a thickness of 15 cm and an inner radius of 10 cm covers 95.2% of the solid angle. On-line measurement method of neutron capture reaction cross section is established on the back-streaming white neutron source of China spallation neutron source by using the upgraded facility. The cross section of 〈sup〉197〈/sup〉Au neutron capture reaction is measured for the first time under the experimental condition of irregular 30 mm neutron beam spot. The measured position of resonance peak is well consistent with the relevant data of ENDF evaluation database, which verifies the reliability of the measurement device and measurement technology, and thus laying the foundation for the acquisition of high precision cross section in future.
    Type of Medium: Online Resource
    ISSN: 1000-3290 , 1000-3290
    Language: Unknown
    Publisher: Acta Physica Sinica, Chinese Physical Society and Institute of Physics, Chinese Academy of Sciences
    Publication Date: 2021
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 3
    Online Resource
    Online Resource
    Acta Physica Sinica, Chinese Physical Society and Institute of Physics, Chinese Academy of Sciences ; 2021
    In:  Acta Physica Sinica Vol. 70, No. 8 ( 2021), p. 082901-
    In: Acta Physica Sinica, Acta Physica Sinica, Chinese Physical Society and Institute of Physics, Chinese Academy of Sciences, Vol. 70, No. 8 ( 2021), p. 082901-
    Abstract: At present, there exist few proton-beam terminals for the detector calibration in the world. Meanwhile, most of these terminals provide monoenergetic protons. Back-n white neutron source from China Spallation Neutron Source(CSNS) was put into operation in 2018. Based on the white neutron flux ranging from 0.5 eV to 200 MeV from the CSNS Back-n white neutron source, continuous-energy protons involved in a wide energy spectrum can be acquired from the 〈sup〉1〈/sup〉H(n, el) reaction. Adopting this method, a new research platform for researches such as proton calibration is realized at CSNS. As hydrogen exists as gas at normal temperature and pressure, in the selecting of the proton-converting target, the hydrogen-rich compounds are preferential considered. Considering the reaction cross sections of the 〈sup〉1〈/sup〉H(n, el), 〈sup〉12〈/sup〉C(n, p)〈sup〉12〈/sup〉B, 〈sup〉12〈/sup〉C(n, d)〈sup〉11〈/sup〉B, 〈sup〉12〈/sup〉C(n, t)〈sup〉10〈/sup〉B, 〈sup〉12〈/sup〉C(n, 〈sup〉3〈/sup〉He)〈sup〉10〈/sup〉Be, 〈sup〉12〈/sup〉C(n, α)〈sup〉9〈/sup〉Be and 〈sup〉1〈/sup〉H(n, γ)〈sup〉2〈/sup〉H, polyethylene and polypropylene are suitable for serving as targets in this research. Based on a 3U PXIe, digitizers with 1 GSps sampling rate and 12 bit resolution are utilized to digitize and record the output signals of telescopes. The time and amplitude information of each signal are extracted from its recorded waveform. Proton fluxes can be calculated by using the neutron energy spectrum and the cross section of the 〈sup〉1〈/sup〉H(n, el) reaction. Using the γ-flash event as the starting time of the time-of-flight (TOF) and the time information of signal in detector as the stopping time, the kinematic energy of each secondary proton can be deduced from the TOF and the angle of the detector. A calibration experiment on three charged particle telescopes, with each telescope consisting of a silicon detector and a CsI(Tl) detector, is carried out on this research platform. The readout methods of the CsI(Tl) detectors in these three telescopes are different. In the calibration experiment, Δ〈i〉E-〈/i〉〈i〉E〈/i〉 two-dimensional spectra and amplitude-〈i〉E〈/i〉〈sub〉p〈/sub〉 two-dimensional spectra of these telescopes are obtained. Through comparing these particle identification spectra, the SiPM is chosen as the signal readout method for CsI(Tl) detectors in the charged particle telescopes. These researches provide experimental evidence for the construction of the charged particle telescope at Back-n, and also illustrate the feasibility of wide-energy spectrum proton calibration based on the Back-n white neutron source.
    Type of Medium: Online Resource
    ISSN: 1000-3290 , 1000-3290
    Language: Unknown
    Publisher: Acta Physica Sinica, Chinese Physical Society and Institute of Physics, Chinese Academy of Sciences
    Publication Date: 2021
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 4
    Online Resource
    Online Resource
    Acta Physica Sinica, Chinese Physical Society and Institute of Physics, Chinese Academy of Sciences ; 2020
    In:  Acta Physica Sinica Vol. 69, No. 17 ( 2020), p. 172901-
    In: Acta Physica Sinica, Acta Physica Sinica, Chinese Physical Society and Institute of Physics, Chinese Academy of Sciences, Vol. 69, No. 17 ( 2020), p. 172901-
    Abstract: The back-streaming neutron beam line (Back-n) was built in the beginning of 2018, which is part of the China Spallation Neutron Source (CSNS). The Back-n is the first white neutron beam line in China, and its main application is for nuclear data measurement. For most of neutron-induced nuclear reaction measurements based on white neutron facilities, the beam of gamma rays accompanied with neutron beam is one of the most important experimental backgrounds. The back streaming neutron beam is transported directly from the spallation target to the experimental station without any moderator or shielding, the flux of the in-beam gamma rays in the experimental station is much larger than those of these facilities with neutron moderator and shielding. Therefore, it is necessary to consider the influence of in-beam gamma rays on the experimental results. Studies of the in-beam gamma rays are carried out at the back-n. Monte-Carlo simulation is employed to obtain the energy distribution and the time structure of the in-beam gamma rays. According to the simulation results, when the neutron flight time is longer than 1.0 μs the energy distribution of the in-beam gamma rays does not vary with flight time. Therefore, the time structure of these gamma rays can be measured without the correction of the detection efficiency. In this work, the time structure of the in-beam gamma rays in the low neutron energy region is measured by both direct and indirect methods. In the direct measurement, a 〈sup〉6〈/sup〉Li loaded ZnS(Ag) scintillator is located on the neutron beam line and the time of flight method is used to determine the time structure of neutrons and gamma rays. The gamma rays are separated from neutrons with pulse-shape discrimination. The black filter method is used to verify the particle discrimination results. In the indirect measurement, the C〈sub〉6〈/sub〉D〈sub〉6〈/sub〉 scintillation detectors are used to measure the gamma rays scattered off a Pb sample on the way of the neutron beam. The time structure of the in-beam gamma rays is derived from that of the scattered gamma rays. The experimental results are in good agreement with the simulations with the time-of-flight between 12 μs and 2.0 ms. Besides, according to the simulation results, the intensity of the in-beam gamma rays is 1.21 × 10〈sup〉6〈/sup〉 s〈sup〉–1〈/sup〉·cm〈sup〉–2〈/sup〉 in the center of the experimental station 2 of Back-n, which is 76.5 m away from the spallation target of CSNS.
    Type of Medium: Online Resource
    ISSN: 1000-3290 , 1000-3290
    Language: Unknown
    Publisher: Acta Physica Sinica, Chinese Physical Society and Institute of Physics, Chinese Academy of Sciences
    Publication Date: 2020
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 5
    In: Chinese Journal of Traumatology, Elsevier BV, Vol. 24, No. 6 ( 2021-11), p. 311-319
    Type of Medium: Online Resource
    ISSN: 1008-1275
    Language: English
    Publisher: Elsevier BV
    Publication Date: 2021
    detail.hit.zdb_id: 2421696-3
    SSG: 6,25
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 6
    Online Resource
    Online Resource
    Elsevier BV ; 2021
    In:  Journal of Traffic and Transportation Engineering (English Edition) Vol. 8, No. 6 ( 2021-12), p. 815-999
    In: Journal of Traffic and Transportation Engineering (English Edition), Elsevier BV, Vol. 8, No. 6 ( 2021-12), p. 815-999
    Type of Medium: Online Resource
    ISSN: 2095-7564
    Language: English
    Publisher: Elsevier BV
    Publication Date: 2021
    detail.hit.zdb_id: 2817145-7
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 7
    In: Diabetes, American Diabetes Association, Vol. 67, No. 5 ( 2018-05-01), p. 861-871
    Abstract: Strong associations between HLA alleles and infectious and autoimmune diseases are well established. Although obesity is also associated with these diseases, the relationship between HLA and obesity has not been systematically investigated in a large cohort. In the current study, we analyzed the association of HLA alleles with BMI using data from 1.3 million healthy adult donors from the Chinese Marrow Donor Program (CMDP). We found 23 HLA alleles, including 12 low-resolution and 11 high-resolution alleles, were significantly associated with BMI after correction for multiple testing. Alleles associated with high BMI were enriched in haplotypes that were common in both Chinese and European populations, whereas the alleles associated with low BMI were enriched in haplotypes common only in Asians. Alleles B*07, DRB1*07, DRB1*12, and C*03:02 provided the strongest associations with BMI (P = 6.89 × 10−10, 1.32 × 10−9, 1.52 × 10−9, and 4.45 × 10−8, respectively), where B*07 and DRB1*07 also had evidence for sex-specific effects (Pheterogeneity = 0.0067 and 0.00058, respectively). These results, which identify associations between alleles of HLA-B, DRB1, and C with BMI in Chinese young adults, implicate a novel biological connection between HLA alleles and obesity.
    Type of Medium: Online Resource
    ISSN: 0012-1797 , 1939-327X
    Language: English
    Publisher: American Diabetes Association
    Publication Date: 2018
    detail.hit.zdb_id: 1501252-9
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 8
    In: Acta Physica Sinica, Acta Physica Sinica, Chinese Physical Society and Institute of Physics, Chinese Academy of Sciences, Vol. 70, No. 24 ( 2021), p. 248703-
    Abstract: Terahertz scattering scanning near-field optical microscopy (s-SNOM), as an important means to break through the limits of conventional optical diffraction, can achieve super-resolution imaging on a nanoscale and has a wide range of applications in biological nano-imaging, terahertz nano-spectroscopy, nanomaterials imaging, and the study of polarized excitations. As an important component of the terahertz s-SNOM, the atomic force microscope tip plays a key role in implementing the near-field excitation, detection, and enhancement. However, the tip-sample interaction can greatly affect the results. In this paper, the effects of tip-sample interaction on near-field excitation, near-field detection, and terahertz near-field spectrum in terahertz s-SNOM are revealed through simulations and experiments. First, the wave vector coupling weight of the near field excited by the tip is investigated, and it is found that the wave vector is concentrated mainly on the order of 10〈sup〉5〈/sup〉 cm〈sup〉–1〈/sup〉, which differs from that of the general terahertz excitations by 2 to 3 orders of magnitude, indicating that the terahertz near field is difficult to excite terahertz excitations. Secondly, through theoretical and experimental studies, it is found that the metal tip interferes with the surface near-field of the graphene disk structure, which indicates the limitations of the terahertz s-SNOM in probing the near-field distribution of the structure. Finally, the influence of the tip on the near-field spectrum is studied. It is found that the tip length and cantilever length are important parameters affecting the near-field spectrum, and the influence of the tip on the near-field spectrum can be reduced by increasing the tip length or cantilever length.
    Type of Medium: Online Resource
    ISSN: 1000-3290 , 1000-3290
    Language: Unknown
    Publisher: Acta Physica Sinica, Chinese Physical Society and Institute of Physics, Chinese Academy of Sciences
    Publication Date: 2021
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 9
    In: Frontiers in Medicine, Frontiers Media SA, Vol. 9 ( 2023-1-4)
    Abstract: Resuscitation transfer of embryos after elective cryopreservation has been widely applied in in vitro fertilization-embryo transfer (IVF-ET) therapy for human infertility or sterility owing to higher embryo implantation rates. This method separates oocyte retrieval from embryo transfer. The optimal time for frozen embryo transfer (FET) remains unknown. Therefore, this study mainly compares the advantages and disadvantages of delayed FET and immediate FET through retrospective analysis. Methods We analyzed real world data of patients who underwent resuscitation transplantation between October 2019 and July 2021 at the Reproductive Center of Chengdu Jinjiang Hospital for Women’s and Children’s Health. Propensity score matching was applied to control potential confounding factors. A total of 5,549 patients who received at least one FET were analyzed. Patients undergoing transplantation within 60 days of oocyte retrieval were included in the immediate FET group ( n = 1,265) and those undergoing transplantation & gt; 60 days after retrieval were included in the delayed FET group ( n = 4,284). Results Live birth rates between the two groups were comparable (45.25% vs. 45.76%, p = 0.757). Moreover, no difference was observed in the rates of biochemical pregnancy (64.50% vs. 66.80%), clinical pregnancy (55.24% vs. 56.83%), ectopic pregnancy (1.47% vs. 1.39%), early miscarriage (14.41% vs. 16.20%), late miscarriage (2.21% vs. 2.09%), singleton premature delivery (16.67% vs. 18.29%), and neonatal deformity (1.97% vs. 1.80%). After stratifying the patients based on the type of embryo transferred, number of embryos transferred, FET protocol, and good prognosis criteria, live birth rates remained comparable between the two groups ( p & gt; 0.05). Conclusion Pregnancy outcomes were comparable between the immediate and delayed FET groups.
    Type of Medium: Online Resource
    ISSN: 2296-858X
    Language: Unknown
    Publisher: Frontiers Media SA
    Publication Date: 2023
    detail.hit.zdb_id: 2775999-4
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 10
    In: Journal of Materials Chemistry A, Royal Society of Chemistry (RSC), Vol. 3, No. 38 ( 2015), p. 19277-19281
    Type of Medium: Online Resource
    ISSN: 2050-7488 , 2050-7496
    Language: English
    Publisher: Royal Society of Chemistry (RSC)
    Publication Date: 2015
    detail.hit.zdb_id: 2702232-8
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...