GLORIA

GEOMAR Library Ocean Research Information Access

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    In: Otology & Neurotology, Ovid Technologies (Wolters Kluwer Health), Vol. 42, No. 7 ( 2021-08), p. e849-e857
    Abstract: There are no approved pharmacologic therapies for chronic sensorineural hearing loss (SNHL). The combination of CHIR99021+valproic acid (CV, FX-322) has been shown to regenerate mammalian cochlear hair cells ex vivo . The objectives were to characterize the cochlear pharmacokinetic profile of CV in guinea pigs, then measure FX-322 in human perilymph samples, and finally assess safety and audiometric effects of FX-322 in humans with chronic SNHL. Study Designs: Middle ear residence, cochlear distribution, and elimination profiles of FX-322 were assessed in guinea pigs. Human perilymph sampling following intratympanic FX-322 dosing was performed in an open-label study in cochlear implant subjects. Unilateral intratympanic FX-322 was assessed in a Phase 1b prospective, randomized, double-blinded, placebo-controlled clinical trial. Setting: Three private otolaryngology practices in the US. Patients: Individuals diagnosed with mild to moderately severe chronic SNHL (≤70 dB standard pure-tone average) in one or both ears that was stable for ≥6 months, medical histories consistent with noise-induced or idiopathic sudden SNHL, and no significant vestibular symptoms. Interventions: Intratympanic FX-322. Main Outcome Measures: Pharmacokinetics of FX-322 in perilymph and safety and audiometric effects. Results: After intratympanic delivery in guinea pigs and humans, FX-322 levels in the cochlear extended high-frequency region were observed and projected to be pharmacologically active in humans. A single dose of FX-322 in SNHL subjects was well tolerated with mild, transient treatment-related adverse events (n = 15 FX-322 vs 8 placebo). Of the six patients treated with FX-322 who had baseline word recognition in quiet scores below 90%, four showed clinically meaningful improvements (absolute word recognition improved 18–42%, exceeding the 95% confidence interval determined by previously published criteria). No significant changes in placebo-injected ears were observed. At the group level, FX-322 subjects outperformed placebo group in word recognition in quiet when averaged across all time points, with a mean improvement from baseline of 18.9% ( p  = 0.029). For words in noise, the treated group showed a mean 1.3 dB signal-to-noise ratio improvement ( p  = 0.012) relative to their baseline scores while placebo-treated subjects did not (−0.21 dB, p  = 0.71). Conclusions: Delivery of FX-322 to the extended high-frequency region of the cochlea is well tolerated and enhances speech recognition performance in multiple subjects with stable chronic hearing loss.
    Type of Medium: Online Resource
    ISSN: 1531-7129 , 1537-4505
    Language: English
    Publisher: Ovid Technologies (Wolters Kluwer Health)
    Publication Date: 2021
    detail.hit.zdb_id: 2058738-7
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 2
    Online Resource
    Online Resource
    Wiley ; 2011
    In:  Otolaryngology–Head and Neck Surgery Vol. 144, No. 2 ( 2011-02), p. 274-279
    In: Otolaryngology–Head and Neck Surgery, Wiley, Vol. 144, No. 2 ( 2011-02), p. 274-279
    Abstract: The study objectives were to compare the rate of neural recovery and speech perception performance in children with auditory neuropathy spectrum disorder (ANSD) and children with sensorineural hearing loss (SNHL) from other etiologies. Study Design Cohort study. Setting Academic hospital and cochlear implant center. Subjects and Methods Ten children with ANSD were matched based on type of implant and age at implantation with peers diagnosed with SNHL. Electrically evoked compound action potential (ECAP) recovery functions were obtained to measure neural refractory behaviors in response to stimulation from the cochlear implant. Speech perception performance was measured using speech recognition thresholds (SRTs) for monosyllable and spondee word stimuli. These outcome measures were compared between groups. Results There was no difference in average recovery function exponent in children with ANSD compared to children with SNHL. Similarly, there were no differences in average SRTs in quiet and in noise in children with ANSD compared to children with SNHL. Relationships between SRT and recovery rate were not present within groups or for all subjects for SRT in quiet, but a significant relationship was found for all subjects for SRT in noise ( P =. 04). Conclusions Dyssynchronous neural activity in ANSD may affect temporal encoding of electrical stimulation from a cochlear implant. As a group, children with ANSD did not demonstrate slower neural recovery compared to those with SNHL, but there was slower neural recovery observed for some subjects. The utility of ECAP recovery functions on optimizing the stimulation rate for individual patients with ANSD requires further investigation.
    Type of Medium: Online Resource
    ISSN: 0194-5998 , 1097-6817
    Language: English
    Publisher: Wiley
    Publication Date: 2011
    detail.hit.zdb_id: 2008453-5
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 3
    Online Resource
    Online Resource
    American Speech Language Hearing Association ; 2021
    In:  Journal of Speech, Language, and Hearing Research Vol. 64, No. 3 ( 2021-03-17), p. 1040-1052
    In: Journal of Speech, Language, and Hearing Research, American Speech Language Hearing Association, Vol. 64, No. 3 ( 2021-03-17), p. 1040-1052
    Abstract: The aims of this study were (a) to longitudinally assess environmental sound recognition (ESR) before and after cochlear implantation in a sample of postlingually deafened adults and (b) to assess the extent to which spectro-temporal processing abilities influence ESR with cochlear implants (CIs). Method In a longitudinal cohort study, 20 postlingually deafened adults were tested with hearing aids on the Familiar Environmental Sound Test–Identification and AzBio sentences in quiet pre-CI and 6 months post-CI. A subset of 11 participants were also tested 12 months post-CI. Pre-CI spectro-temporal processing was assessed using the Spectral-temporally Modulated Ripple Test. Results Average ESR accuracy pre-CI ( M = 63.60%) was not significantly different from ESR accuracy at 6 months ( M = 65.40%) or 12 months ( M = 69.09%) post-CI. In 11 participants (55%), however, ESR improved following implantation by 10.91 percentage points, on average. Pre-CI ESR correlated moderately and significantly with pre-CI and 12-month post-CI AzBio scores, with a trend toward significance for AzBio performance at 6 months. Pre-CI spectro-temporal processing was moderately associated with ESR at 6 and 12 months post-CI but not with speech recognition post-CI. Conclusions The present findings failed to demonstrate an overall significant improvement in ESR following implantation. Nevertheless, more than half of our sample showed some degree of improvement in ESR. Several environmental sounds were poorly identified both before and after implantation. Spectro-temporal processing ability prior to implantation appears to predict postimplantation performance for ESR. These findings indicate the need for greater attention to ESR following cochlear implantation and for developing individualized targets for ESR rehabilitation. Supplemental Material https://doi.org/10.23641/asha.13876745
    Type of Medium: Online Resource
    ISSN: 1092-4388 , 1558-9102
    Language: English
    Publisher: American Speech Language Hearing Association
    Publication Date: 2021
    detail.hit.zdb_id: 2070420-3
    SSG: 5,2
    SSG: 7,11
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 4
    In: The Laryngoscope, Wiley, Vol. 114, No. 8 ( 2004-08), p. 1355-1361
    Abstract: Objective: Magnetic resonance imaging (MRI) has been contraindicated when cochlear implants containing an internal magnet are in place because of concerns regarding torque, force, demagnetization, artifacts, induced voltages, and heating. The objective was to determine the magnetic field strength of Med‐El Combi 40+ cochlear implant internal magnets after MRI studies. Study Design/Methods: Two fresh cadavers were used to study demagnetization using a repeated measures design and a magnetometer. Pre‐ and postMRI measurement of magnetic field strength was completed. Five sets of sagittal T1‐weighted, axial T1‐weighted, and axial T2‐weighted sequences were performed on a cadaver at 0.2 Tesla in the device‐up and device‐down positions. In the other cadaver, 15 sets of sagittal T1‐weighted, axial T1‐weighted, and axial T2‐weighted sequences were performed on a cadaver at 1.5 Tesla were conducted, 5 each with the head oriented at 80, 90, and 100 degrees rotated around the yaw plane (rotated around the z‐axis). Subsequently, three cochlear implant patients completed 0.2 Tesla MRIs. For these patients, subjective and objective assessment of cochlear implant performance was performed. Setting: Academic medical center. Results: In the cadaver studies, analysis of variance showed no significant difference in the magnetic field strength after the 0.2 or 1.5 Tesla scans. There was no significant difference in the magnetic field strength for the three patients undergoing 0.2 Tesla MRIs and no adverse consequences, including no changes in telemetry, auditory sensations, nonauditory sensations, and sound quality. Conclusions: No significant demagnetization of the internal magnet occurred during repeated 1.5 Tesla MRI scans with the head orientations used in this study. In the cochlear implant patients, no significant demagnetization of the internal magnet occurred after a 0.2 Tesla MRI.
    Type of Medium: Online Resource
    ISSN: 0023-852X , 1531-4995
    Language: English
    Publisher: Wiley
    Publication Date: 2004
    detail.hit.zdb_id: 2026089-1
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 5
    Online Resource
    Online Resource
    Wiley ; 2004
    In:  The Laryngoscope Vol. 114, No. 12 ( 2004-12), p. 2252-2254
    In: The Laryngoscope, Wiley, Vol. 114, No. 12 ( 2004-12), p. 2252-2254
    Abstract: Hypothesis: Monopolar electrosurgery below the neck in cochlear implant recipients can be performed without damage to the internal cochlear stimulator, electrode array, and the cochlear nerve. Study Design: Prospective pre‐ and postintervention electrically evoked compound action potential (ECAP) study of cochlear nerve function and behavioral sound perception assessment. Methods: Neural response telemetry (NRT) was used to measure ECAPs before and after the use of monopolar electrosurgery during coronary artery bypass surgery to assess prosthetic device function and electrophysiologic function of the cochlear nerve. In addition, electrode voltage impedances and behavioral sound perception was measured at the same time intervals. Results: ECAPs, behavioral sound perception, and electrode voltage impedances were within the normal range, within compliance, and similar preoperatively and on postoperative day 6. Conclusion: The studies reported herein were a series of measurements designed to test neural integrity and prosthetic device function before and after the use of monopolar electrosurgery. With appropriate precautions, use of monopolar electrosurgery below the neck in cochlear implant recipients can be performed safely.
    Type of Medium: Online Resource
    ISSN: 0023-852X , 1531-4995
    Language: English
    Publisher: Wiley
    Publication Date: 2004
    detail.hit.zdb_id: 2026089-1
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 6
    In: The Laryngoscope, Wiley, Vol. 114, No. 4 ( 2004-04), p. 607-611
    Abstract: Objectives/Hypothesis Mutations in the connexin 26 (Cx26) or gap junction beta 2 gene are the leading cause of hereditary nonsyndromic sensorineural hearing loss in Caucasians. The Cx26 coding region of 68 children with nonsyndromic sensorineural hearing loss was sequenced to determine the frequency and type of Cx26 mutations in this population. Screening was also performed for a common connexin 30 (Cx30) or gap junction beta 6 mutation (del [GJB6‐D13S1830]). Children also underwent audiological testing to determine whether any correlation exists between Cx26 mutations and severity of hearing loss. Study Design In all, 68 children with nonsyndromic sensorineural hearing loss were screened for Cx26 and Cx30 mutations by polymerase chain reaction and direct sequencing. Methods Genomic DNA was amplified by polymerase chain reaction using primers that flank the entire Cx26 coding region. Screening for the 342‐kb Cx30 deletion was performed using primers that amplified the breakpoint junction of the deletion. The amplicons were then sequenced in both directions and analyzed for mutations. Audiometric testing, including pure‐tone audiometry and auditory evoked brainstem response, was also performed to determine the degree of hearing loss. Results Twenty‐seven of 68 children tested had mutations in Cx26 with 35delG being the most prevalent. Ten additional Cx26 mutations were detected including a novel compound heterozygote. Two children were heterozygous for the Cx30 del (GJB6‐D13S1830) mutation. Conclusion Cx26 and Cx30 mutations were present in 41.2% of children tested in the study population. Audiometric data supported previous studies demonstrating a greater degree of hearing loss in subjects who are homozygous for the 35delG mutation.
    Type of Medium: Online Resource
    ISSN: 0023-852X , 1531-4995
    Language: English
    Publisher: Wiley
    Publication Date: 2004
    detail.hit.zdb_id: 2026089-1
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 7
    In: The Laryngoscope, Wiley, Vol. 119, No. S1 ( 2009-01)
    Type of Medium: Online Resource
    ISSN: 0023-852X , 1531-4995
    URL: Issue
    Language: English
    Publisher: Wiley
    Publication Date: 2009
    detail.hit.zdb_id: 2026089-1
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 8
    In: Otology & Neurotology, Ovid Technologies (Wolters Kluwer Health), Vol. 25, No. 5 ( 2004-09), p. 752-761
    Type of Medium: Online Resource
    ISSN: 1531-7129
    Language: English
    Publisher: Ovid Technologies (Wolters Kluwer Health)
    Publication Date: 2004
    detail.hit.zdb_id: 2058738-7
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 9
    Online Resource
    Online Resource
    Elsevier BV ; 2014
    In:  Operative Techniques in Otolaryngology-Head and Neck Surgery Vol. 25, No. 4 ( 2014-12), p. 344-347
    In: Operative Techniques in Otolaryngology-Head and Neck Surgery, Elsevier BV, Vol. 25, No. 4 ( 2014-12), p. 344-347
    Type of Medium: Online Resource
    ISSN: 1043-1810
    Language: English
    Publisher: Elsevier BV
    Publication Date: 2014
    detail.hit.zdb_id: 2135189-2
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 10
    Online Resource
    Online Resource
    Georg Thieme Verlag KG ; 2011
    In:  Journal of the American Academy of Audiology Vol. 22, No. 09 ( 2011-10), p. 567-577
    In: Journal of the American Academy of Audiology, Georg Thieme Verlag KG, Vol. 22, No. 09 ( 2011-10), p. 567-577
    Abstract: Background: The challenges associated with auditory neuropathy spectrum disorder (ANSD) are due primarily to temporal impairment and therefore tend to affect perception of low- to midfrequency sounds. A common treatment option for severe impairment in ANSD is cochlear implantation, and because the degree of impairment is unrelated to degree of hearing loss by audiometric thresholds, this population may have significant acoustic sensitivity in the contralateral ear. Clinically, the question arises as to how we should treat the contralateral ear in this population when there is acoustic hearing—should we plug it, amplify it, implant it, or leave it alone? Purpose: The purpose of this study was to examine the effects of acute amplification and plugging of the contralateral ear compared to no intervention in implanted children with ANSD and aidable contralateral hearing. It was hypothesized that due to impaired temporal processing in ANSD, contralateral acoustic input would interfere with speech perception achieved with the cochlear implant (CI) alone; therefore, speech perception performance will decline with amplification and improve with occlusion. Research Design: Prospective within-subject comparison. Adaptive speech recognition thresholds (SRTs) for monosyllable and spondee word stimuli were measured in quiet and in noise for the intervention configurations. Study Sample: Nine children treated at the Medical College of Wisconsin Koss Cochlear Implant Program participated in the study. Inclusion criteria for this study were children diagnosed with ANSD who were unilaterally implanted, had aidable hearing in the contralateral ear (defined as a three-frequency pure-tone average of ≤80 dB HL), had at least 1 yr of cochlear implant experience, and were able to perform the speech perception task. Intervention: We compared SRT with the CI alone to SRTs with interventions of cochlear implant with a contralateral hearing aid (CI+HA) and cochlear implant with a contralateral earplug (CI+plug). Data Collection and Analysis: SRTs were measured and compared within subjects across listening conditions. Within-subject comparisons were analyzed using paired t-tests, and analyses of predictive variables for effects of contralateral intervention were analyzed using linear regression. Results: Contrary to the hypothesis, the bimodal CI+HA configuration showed a significant improvement in mean performance over the CI-alone configuration in quiet (p = .04). In noise, SRTs were obtained for six subjects, and no significant bimodal benefit was observed (p = .09). There were no consistent effects of occlusion observed across subjects and stimulus conditions. Degree of bimodal benefit showed a significant relationship with performance with the CI alone, with greater bimodal benefit associated with poorer CI-alone performance (p = .01). This finding, however, was limited by floor effects. Conclusions: The results of this study indicate that children with ANSD who are experienced cochlear implant users may benefit from contralateral amplification, particularly for moderate cochlear implant performers. It is unclear from these data whether long-term contralateral hearing aid use in real-world situations would ultimately benefit this population; however, a hearing aid trial is recommended with assessment of bimodal benefit over time. These data may help inform clinical guidelines for determining optimal hearing configurations for unilaterally implanted children with ANSD, particularly when considering candidacy for sequential cochlear implantation.
    Type of Medium: Online Resource
    ISSN: 1050-0545 , 2157-3107
    Language: English
    Publisher: Georg Thieme Verlag KG
    Publication Date: 2011
    detail.hit.zdb_id: 2069736-3
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...