GLORIA

GEOMAR Library Ocean Research Information Access

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    In: Neurosurgical Focus, Journal of Neurosurgery Publishing Group (JNSPG), Vol. 43, No. 2 ( 2017-08), p. E2-
    Abstract: In traumatic spondylolistheses of the axis, there is a marked heterogeneity of the observed injury patterns, with a wide range of the severity—from stable fractures, which can be treated conservatively with very good success, to highly unstable fractures, which should be treated surgically. A number of classification systems have been devised to assess the instability of the injuries and to derive a corresponding therapy recommendation. In particular, the results and recommendations regarding medium-severity cases are still inconclusive. Minimally invasive percutaneous procedures performed using modern techniques such as 3D fluoroscopy and neuronavigation have the potential for improvements in the therapeutic outcome and procedural morbidity against open surgical procedures and conservative therapy. METHODS A minimally invasive method using 3D fluoroscopy and neuronavigation for percutaneous lag screw osteosynthesis of the pars interarticularis was performed in 12 patients with a Levine-Edwards Type II fracture. Ten patients had an isolated hangman’s fracture and 2 patients had an additional odontoid fracture of the axis (Type II according to the Anderson and D’Alonzo classification system). Complications, operating parameters, screw positions, and bony fusion were evaluated for the description and evaluation of the technique. RESULTS In 6 men and 6 women, percutaneous lag screw osteosynthesis was performed successfully. Correct placement could be verified postoperatively for all inserted screws. In the case series, nonunion was not observed. In all patients with a complete follow-up, a bony fusion, an intact vertebral alignment, and no deformity could be detected on CT scans obtained after 3 months. CONCLUSIONS The percutaneous pars interarticularis lag screw osteosynthesis is a minimally invasive and mobility-preserving surgical technique. Its advantages over alternative methods are its minimal invasiveness, a shortened treatment time, and high fusion rates. The benefits are offset by the risk of injury to the vertebral arteries. The lag screw osteosynthesis is only possible with Levine-Edwards Type II fractures, because the intervertebral joints to C-3 are functionally preserved. A further development and evaluation of the operative technique as well as comparison with conservative and alternative surgical treatment options are deemed necessary.
    Type of Medium: Online Resource
    ISSN: 1092-0684
    Language: Unknown
    Publisher: Journal of Neurosurgery Publishing Group (JNSPG)
    Publication Date: 2017
    detail.hit.zdb_id: 2026589-X
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 2
    Online Resource
    Online Resource
    Journal of Neurosurgery Publishing Group (JNSPG) ; 2016
    In:  Journal of Neurosurgery: Spine Vol. 25, No. 1 ( 2016-07), p. 103-109
    In: Journal of Neurosurgery: Spine, Journal of Neurosurgery Publishing Group (JNSPG), Vol. 25, No. 1 ( 2016-07), p. 103-109
    Abstract: Loosening and pullout of pedicle screws are well-known problems in pedicle screw fixation surgery. Augmentation of pedicle screws with bone cement, first described as early as 1975, increases the pedicle-screw interface and pullout force in osteoporotic vertebrae. The aim of the present study was to identify cement leakage and pulmonary embolism rates in a large prospective single-center series of pedicle screw augmentations. METHODS All patients who underwent cement-augmented pedicle screw placement between May 2006 and October 2010 at the authors' institution were included in this prospective cohort study. Perivertebral cement leakage and pulmonary cement embolism were evaluated with a CT scan of the area of operation and with a radiograph of the chest, respectively. RESULTS A total of 98 patients underwent placement of cement-augmented pedicle screws; 474 augmented screws were inserted in 237 vertebrae. No symptomatic perivertebral cement leakage or symptomatic pulmonary cement embolism was observed, but asymptomatic perivertebral cement leakage was seen in 88 patients (93.6%) and in 165 augmented vertebrae (73.3%). Cement leakage most often occurred in the perivertebral venous system. Clinically asymptomatic pulmonary cement embolism was found in 4 patients (4.1%). CONCLUSIONS Perivertebral cement leakage often occurs in pedicle screw augmentation, but in most cases, it is clinically asymptomatic. Cement augmentation should be performed under continuous fluoroscopy to avoid high-volume leakage. Alternative strategies, such as use of expandable screws, should be examined in more detail for patients at high risk of screw loosening.
    Type of Medium: Online Resource
    ISSN: 1547-5654
    RVK:
    Language: Unknown
    Publisher: Journal of Neurosurgery Publishing Group (JNSPG)
    Publication Date: 2016
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 3
    In: Operative Neurosurgery, Ovid Technologies (Wolters Kluwer Health), Vol. 14, No. 2 ( 2018-02), p. 121-127
    Type of Medium: Online Resource
    ISSN: 2332-4252 , 2332-4260
    Language: English
    Publisher: Ovid Technologies (Wolters Kluwer Health)
    Publication Date: 2018
    detail.hit.zdb_id: 2886024-X
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...