GLORIA

GEOMAR Library Ocean Research Information Access

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    In: Journal of Cardiovascular Electrophysiology, Wiley, Vol. 27, No. 7 ( 2016-07), p. 779-784
    Abstract: Atrial fibrillation (AF) is an important prognostic parameter in patients with hypertrophic cardiomyopathy (HCM). Though cardiac rhythm management (CRM) devices (e.g., ICD, pacemaker or implantable loop recorder) can detect subclinical AF, data describing the incidence of AF are rare. We therefore investigated the incidence and clinical impact of de novo and subclinical AF detected by CRM devices in patients with HCM. Methods and Results In our retrospective single‐center study, we included patients with HCM and need for CRM devices. The primary endpoint of the study was the incidence of clinical and subclinical de novo AF. During follow‐up, patients were screened for adverse events like stroke, ventricular arrhythmia, heart failure, or death. From 192 HCM patients, 44 patients received a CRM device (38 ICDs, 5 pacemakers, 1 implantable loop recorder). In 14 of these patients (32%), AF had been documented before device implantation. Thirty (68%) patients were free from AF at the time of implantation. During a median follow‐up of 595 days (interquartile range, 367–890 days), de novo AF was recorded in 16 of these 30 patients (53%). Fourteen (88%) of the 16 patients with de novo AF were free from any clinical symptoms, so these patients were classified to have subclinical AF. In logistic regression analysis, age was the only significant predictor for an increased risk of AF. Conclusion AF is common in patients with HCM who need a CRM device. More than 50% of these patients develop de novo AF that was predominantly subclinical in our cohort.
    Type of Medium: Online Resource
    ISSN: 1045-3873 , 1540-8167
    URL: Issue
    Language: English
    Publisher: Wiley
    Publication Date: 2016
    detail.hit.zdb_id: 2037519-0
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 2
    Online Resource
    Online Resource
    Oxford University Press (OUP) ; 2019
    In:  Interactive CardioVascular and Thoracic Surgery ( 2019-10-21)
    In: Interactive CardioVascular and Thoracic Surgery, Oxford University Press (OUP), ( 2019-10-21)
    Abstract: OBJECTIVES Transvenous coronary sinus leads are considered to be the gold standard for cardiac resynchronization therapy (CRT). However, in patients with abnormal coronary vein anatomy, the epicardial leads can be an alternative. Data comparing durability and performance of these 2 lead types are limited. In order to provide clarity, we investigated patients receiving CRT system in our centre. METHODS One thousand and fifty-three consecutive patients scheduled for CRT implantation were retrospectively analysed. From these, 895 received transvenous coronary sinus and 158 epicardial left ventricular (LV) leads. Lead-specific as well as LV functional parameters have been evaluated in 60 months’ follow-up. RESULTS Technical characteristics (pacing threshold, impedance and sensing) of both lead types remained stable during the whole observation period. Whereas an early revision ( 〈 6 month) was noted in 5.4% of transvenous leads, no reintervention has been necessary for epicardial leads. During the 5-year observation period, a lead revisions rate of 10.2% for transvenous leads and 1.9% for epicardial leads were detected. Regarding CRT efficacy, excellent results were achieved for both electrode types. In both groups, a statistically significant reduction of New York Heart Association class (2.85–2.13 and 2.96–2.09), increase in left ventricular ejection fraction (24.6–32.6% and 27.2–34.6%), reduction of left ventricular end-systolic diameter/left ventricular end-diastolic diameter and reduction in degree of mitral valve insufficiency could be observed over the time. CONCLUSIONS Our data demonstrate safety and functional efficacy of both transvenous and epicardial leads. Moreover, in long-term follow-up, a commendable durability and performance were found for both lead types. Thus, epicardial leads represent a good alternative when transvenous implantation fails.
    Type of Medium: Online Resource
    ISSN: 1569-9285
    Language: English
    Publisher: Oxford University Press (OUP)
    Publication Date: 2019
    detail.hit.zdb_id: 2096257-5
    detail.hit.zdb_id: 3167862-2
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 3
    Online Resource
    Online Resource
    Oxford University Press (OUP) ; 2021
    In:  Interactive CardioVascular and Thoracic Surgery Vol. 32, No. 3 ( 2021-04-08), p. 402-407
    In: Interactive CardioVascular and Thoracic Surgery, Oxford University Press (OUP), Vol. 32, No. 3 ( 2021-04-08), p. 402-407
    Abstract: Transvenous lead extraction using mechanical rotational- or laser sheaths is an established procedure. Lead dwell time has been recognized as a risk factor for extraction failure and procedure-related complications. We therefore investigated the safety and efficacy of transvenous extraction of leads with an implant duration of more than 10 years. METHODS Between January 2013 and March 2017, a total of 403 patients underwent lead extraction in 2 high-volume lead extraction centres. One hundred and fifty-four patients with extraction of at least 1 lead aged over 10 years were included in this analysis. Laser lead extraction was the primary extraction method, with additional use of mechanical rotational sheaths or femoral snares, if necessary. All procedural- and patient-based data were collected into a database and retrospectively analysed. RESULTS Mean patient’s age was 65.8 ± 15.8 years, 68.2% were male. Three hundred and sixty-two leads had to be extracted. The mean lead dwell time of treated leads was 14.0 ± 6.1 years. Complete procedural success was achieved in 91.6% of cases, while clinical success was achieved in 96.8%. Failure of extraction occurred in 3.2%. Leads that could not be completely removed had a significantly longer lead dwell time (18.2 vs 13.2 years; P = 0.016). Additional mechanical rotational sheaths or femoral snares were used in 26 (16.9%) patients. Overall complication rate was 4.6%, including 5 (3.3%) major and 2 (1.3%) minor complications. There was no procedure-related mortality. CONCLUSIONS Transvenous lead extraction in leads aged over 10 years is safe and effective when performed in specialized centres and with use of multiple tools and techniques. Leads that could not be completely extracted had a statistically significant longer lead dwell time.
    Type of Medium: Online Resource
    ISSN: 1569-9285
    Language: English
    Publisher: Oxford University Press (OUP)
    Publication Date: 2021
    detail.hit.zdb_id: 2096257-5
    detail.hit.zdb_id: 3167862-2
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 4
    In: Journal of Cardiovascular Electrophysiology, Wiley, Vol. 31, No. 4 ( 2020-04), p. 854-859
    Abstract: Many patients awaiting heart transplantation (HTX) have a cardiac implantable electronic device (CIED). Lead removal is often still a part of the HTX procedure. Abandoned lead fragments carry a risk for infections and prohibit magnetic resonance imaging (MRI) imaging. This study evaluated the concept of an elective lead management algorithm after HTX. Methods and Results Between 2009 and 2018, 102 consecutive patients with previously implanted CIED underwent HTX. Lead removal by manual traction during HTX was performed in 74 patients until December 2014. Afterward, treatment strategy was changed and 28 patients received elective lead extraction procedures in a hybrid operating room (OR) using specialized extraction tools. Total of 74 patients with 157 leads underwent lead extraction by manual traction during HTX. The mean lead age was 32.3 ± 38.7 months. Postoperative X‐ray revealed abandoned intravascular lead fragments in 31(41.9%) patients, resulting in a complete lead extraction rate of only 58.1%. The high rate of unsuccessful lead extractions led to the change in the extraction strategy in 2015. Since then, HTX was performed in 28 CIED patients. In those patients, 64 leads with a mean lead age of 53.8 ± 42.8 months were treated in an elective lead extraction procedure. No major or minor complications occurred during lead extraction. All leads could be removed completely, resulting in a procedural success rate of 100%. Conclusion Our results demonstrate that chronically implanted leads should be removed in an elective procedure, using appropriate extraction tools. This enables complete lead extraction, which reduces the infection risk in this patient population with the necessity for permanent immunosuppressive therapy and allows further MRI surveillance.
    Type of Medium: Online Resource
    ISSN: 1045-3873 , 1540-8167
    URL: Issue
    Language: English
    Publisher: Wiley
    Publication Date: 2020
    detail.hit.zdb_id: 2037519-0
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 5
    In: European Heart Journal, Oxford University Press (OUP), Vol. 44, No. 27 ( 2023-07-14), p. 2483-2494
    Abstract: Atrial fibrillation (AF) is associated with altered cAMP/PKA signaling and an AF-promoting reduction of L-type Ca2+-current (ICa,L), the mechanisms of which are poorly understood. Cyclic-nucleotide phosphodiesterases (PDEs) degrade cAMP and regulate PKA-dependent phosphorylation of key calcium-handling proteins, including the ICa,L-carrying Cav1.2α1C subunit. The aim was to assess whether altered function of PDE type-8 (PDE8) isoforms contributes to the reduction of ICa,L in persistent (chronic) AF (cAF) patients. Methods and results mRNA, protein levels, and localization of PDE8A and PDE8B isoforms were measured by RT-qPCR, western blot, co-immunoprecipitation and immunofluorescence. PDE8 function was assessed by FRET, patch-clamp and sharp-electrode recordings. PDE8A gene and protein levels were higher in paroxysmal AF (pAF) vs. sinus rhythm (SR) patients, whereas PDE8B was upregulated in cAF only. Cytosolic abundance of PDE8A was higher in atrial pAF myocytes, whereas PDE8B tended to be more abundant at the plasmalemma in cAF myocytes. In co-immunoprecipitation, only PDE8B2 showed binding to Cav1.2α1C subunit which was strongly increased in cAF. Accordingly, Cav1.2α1C showed a lower phosphorylation at Ser1928 in association with decreased ICa,L in cAF. Selective PDE8 inhibition increased Ser1928 phosphorylation of Cav1.2α1C, enhanced cAMP at the subsarcolemma and rescued the lower ICa,L in cAF, which was accompanied by a prolongation of action potential duration at 50% of repolarization. Conclusion Both PDE8A and PDE8B are expressed in human heart. Upregulation of PDE8B isoforms in cAF reduces ICa,L via direct interaction of PDE8B2 with the Cav1.2α1C subunit. Thus, upregulated PDE8B2 might serve as a novel molecular mechanism of the proarrhythmic reduction of ICa,L in cAF.
    Type of Medium: Online Resource
    ISSN: 0195-668X , 1522-9645
    Language: English
    Publisher: Oxford University Press (OUP)
    Publication Date: 2023
    detail.hit.zdb_id: 2001908-7
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 6
    In: Pacing and Clinical Electrophysiology, Wiley, Vol. 44, No. 4 ( 2021-04), p. 601-606
    Abstract: In the aging population equipped with cardiac implantable electronic devices, an increasing number of octogenarians require lead extractions. This patient population is often considered as a high‐risk group for surgical procedures. We, therefore, investigated the safety and efficacy of transvenous lead extraction in octogenarians using powered extraction sheaths. Methods Between January 2013 and March 2017, 403 patients underwent lead extraction at two high‐volume lead extraction centers. A total of 71 octogenarians were treated with laser lead extraction and were included in this analysis. Primary extraction method was laser lead extraction, with additional use of mechanical rotational sheaths or femoral snares, if necessary. Patient‐based and procedural data were collected and analyzed retrospectively. Results Mean age was 83.5 ± 3.3 years, 64.7% were males. A total of 152 leads were extracted. The mean lead dwell time of treated leads was 10.2 ± 5.2 years. Complete procedural success rate was 92.9%, while clinical success was achieved in 98.6%. Failure of extraction occurred in one patient (1.4%). In six (7.7%) patients, additional mechanical rotational sheaths or femoral snares were used. Overall complication rate was 4.2%, including one (1.4%) major (RA perforation) and two (2.8%) minor complications. No procedure‐related mortality was observed in any of the patients. Conclusion Transvenous lead extraction in octogenarians with old leads is safe and effective when performed in experienced centers. Patient's age should therefore not be considered as contraindication for lead extraction using powered extraction sheaths.
    Type of Medium: Online Resource
    ISSN: 0147-8389 , 1540-8159
    URL: Issue
    Language: English
    Publisher: Wiley
    Publication Date: 2021
    detail.hit.zdb_id: 2037547-5
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 7
    In: Journal of Cardiac Surgery, Hindawi Limited, Vol. 30, No. 5 ( 2015-05), p. 469-473
    Type of Medium: Online Resource
    ISSN: 0886-0440
    Language: English
    Publisher: Hindawi Limited
    Publication Date: 2015
    detail.hit.zdb_id: 2108425-7
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 8
    In: Journal of Visualized Experiments, MyJove Corporation, , No. 145 ( 2019-03-18)
    Type of Medium: Online Resource
    ISSN: 1940-087X
    Language: English
    Publisher: MyJove Corporation
    Publication Date: 2019
    detail.hit.zdb_id: 2259946-0
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 9
    Online Resource
    Online Resource
    MyJove Corporation ; 2017
    In:  Journal of Visualized Experiments , No. 119 ( 2017-01-15)
    In: Journal of Visualized Experiments, MyJove Corporation, , No. 119 ( 2017-01-15)
    Type of Medium: Online Resource
    ISSN: 1940-087X
    Language: English
    Publisher: MyJove Corporation
    Publication Date: 2017
    detail.hit.zdb_id: 2259946-0
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 10
    In: Frontiers in Cardiovascular Medicine, Frontiers Media SA, Vol. 10 ( 2023-9-1)
    Abstract: Valve-in-valve (ViV) transfemoral transcatheter aortic valve implantation (TAVI) for failing aortic surgical bioprostheses or transcatheter heart valves (THV) has demonstrated a reasonable clinical and hemodynamic efficacy. Traditionally, self-expanding (SE) supra-annular THV are considered to result in superior hemodynamics compared with balloon-expandable intra-annular THV after ViV. However, so far no data are found on latest-generation intra-annular SE THV for aortic ViV procedures which might be superior with regard to coronary access or subsequent valve reintervention. Aim We herein aim to evaluate a latest-generation SE intra-annular THV for aortic ViV procedures. Materials and methods Between May 2022 and November 2022, five consecutive patients (4/5 female with mean age of 76.2 years and mean Society of Thoracic Surgeons predicted risk of mortality score of 2.9%) received ViV TAVI using the Navitor system (Abbott, Chicago, IL, USA) for treatment of failing surgical bioprostheses or THV. Data were retrospectively analyzed according to updated Valve Academic Research Consortium 3 (VARC-3) definitions. Results At 30 days, absence of mortality and VARC-3 adjudicated clinical endpoints were documented. Echocardiography at 30 days revealed complete absence of paravalvular leakage and single-digit mean transvalvular gradients (mean of 6.0 mmHg) in all patients. Conclusion The investigated intra-annular SE THV results in excellent 30-day outcomes for aortic ViV procedures for failing surgical bioprostheses or THV. Despite the intra-annular design, hemodynamic results were excellent, even in small bioprostheses. Ease of use of this valve platform is reflected by only two cycles of resheathing in five ViV procedures with hemodynamic stability during all steps of valve deployment.
    Type of Medium: Online Resource
    ISSN: 2297-055X
    Language: Unknown
    Publisher: Frontiers Media SA
    Publication Date: 2023
    detail.hit.zdb_id: 2781496-8
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
Close ⊗