One of the most important sequelae affecting long-term results is adjacent-segment degeneration (ASD) after posterior lumbar interbody fusion (PLIF). Although several reports have described the incidence rate, there have been no reports of repeated ASD. The purpose of this report was to describe 1 case of repeated ASD after PLIF. A 62-year-old woman with L-4 degenerative spondylolisthesis underwent PLIF at L4–5. At the second operation, L3–4 PLIF was performed for L-3 degenerative spondylolisthesis 6 years after the primary operation. At the third operation, L2–3 PLIF was performed for L-2 degenerative spondylolisthesis 1.5 years after the primary operation. Vertebral collapse of L-1 was detected 1 year after the third operation, and the collapse had progressed. At the fourth operation, 3 years after the third operation, vertebral column resection of L-1 and replacement of titanium mesh cages with pedicle screw fixation between T-4 and L-5 was performed. Although the patient's symptoms resolved after each operation, the time between surgeries shortened. The sacral slope decreased gradually although each PLIF achieved local lordosis at the fused segment.