In:
Journal AWWA, Wiley, Vol. 64, No. 4 ( 1972-04), p. 238-243
Abstract:
The standard Hardy–Cross method for computing the flow conditions in a network breaks down when booster pumps are added. The authors describe a procedure for modifying the original method, making it practical for almost any utility to establish the effects of changing use patterns within the system.
Type of Medium:
Online Resource
ISSN:
0003-150X
,
1551-8833
DOI:
10.1002/awwa.1972.64.issue-4
DOI:
10.1002/j.1551-8833.1972.tb02680.x
Language:
English
Publisher:
Wiley
Publication Date:
1972
detail.hit.zdb_id:
2144899-1