GLORIA

GEOMAR Library Ocean Research Information Access

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
Material
Person/Organisation
Language
Years
  • 1
    In: American Journal of Hematology, Wiley, Vol. 98, No. 9 ( 2023-09), p. 1394-1406
    Abstract: Chronic myelomonocytic leukemia (CMML) is a clonal hematopoietic stem cell malignancy, and allogeneic hematopoietic stem cell transplantation (allo‐HSCT) is the only curable treatment. The outcomes after transplant are influenced by both disease characteristics and patient comorbidities. To develop a novel prognostic model to predict the post‐transplant survival of CMML patients, we identified risk factors by applying univariable and multivariable Cox proportional hazards regression to a derivation cohort. In multivariable analysis, advanced age (hazard ratio [HR] 3.583), leukocyte count (HR 3.499), anemia (HR 3.439), bone marrow blast cell count (HR 2.095), and no chronic graft versus host disease (cGVHD; HR 4.799) were independently associated with worse survival. A novel prognostic model termed ABLAG (Age, Blast, Leukocyte, Anemia, cGVHD) was developed and the points were assigned according to the regression equation. The patients were categorized into low risk (0–1), intermediate risk (2, 3), and high risk (4–6) three groups and the 3‐year overall survival (OS) were 93.3% (95%CI, 61%–99%), 78.9% (95%CI, 60%–90%), and 51.6% (95%CI, 32%–68%; p   〈  .001), respectively. In internal and external validation cohort, the area under the receiver operating characteristic (ROC) curves of the ABLAG model were 0.829 (95% CI, 0.776–0.902) and 0.749 (95% CI, 0.684–0.854). Compared with existing models designed for the nontransplant setting, calibration plots, and decision curve analysis showed that the ABLAG model revealed a high consistency between predicted and observed outcomes and patients could benefit from this model. In conclusion, combining disease and patient characteristic, the ABLAG model provides better survival stratification for CMML patients receiving allo‐HSCT.
    Type of Medium: Online Resource
    ISSN: 0361-8609 , 1096-8652
    URL: Issue
    Language: English
    Publisher: Wiley
    Publication Date: 2023
    detail.hit.zdb_id: 1492749-4
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 2
    In: American Journal of Hematology, Wiley, Vol. 96, No. 5 ( 2021-05), p. 561-570
    Abstract: Globally, postpartum hemorrhage (PPH) is the leading cause of maternal death. Women with immune thrombocytopenia (ITP) are at increased risk of developing PPH. Early identification of PPH helps to prevent adverse outcomes, but is underused because clinicians do not have a tool to predict PPH for women with ITP. We therefore conducted a nationwide multicenter retrospective study to develop and validate a prediction model of PPH in patients with ITP. We included 432 pregnant women (677 pregnancies) with primary ITP from 18 academic tertiary centers in China from January 2008 to August 2018. A total of 157 (23.2%) pregnancies experienced PPH. The derivation cohort included 450 pregnancies. For the validation cohort, we included 117 pregnancies in the temporal validation cohort and 110 pregnancies in the geographical validation cohort. We assessed 25 clinical parameters as candidate predictors and used multivariable logistic regression to develop our prediction model. The final model included seven variables and was named MONITOR ( m aternal complication, WH O bleeding score, a n tepartum platelet transfusion, placental abnormal i ties, pla t elet count, previ o us uterine surgery, and p r imiparity). We established an easy‐to‐use risk heatmap and risk score of PPH based on the seven risk factors. We externally validated this model using both a temporal validation cohort and a geographical validation cohort. The MONITOR model had an AUC of 0.868 (95% CI 0.828–0.909) in internal validation, 0.869 (95% CI 0.802–0.937) in the temporal validation, and 0.811 (95% CI 0.713–0.908) in the geographical validation. Calibration plots demonstrated good agreement between MONITOR‐predicted probability and actual observation in both internal validation and external validation. Therefore, we developed and validated a very accurate prediction model for PPH. We hope that the model will contribute to more precise clinical care, decreased adverse outcomes, and better health care resource allocation.
    Type of Medium: Online Resource
    ISSN: 0361-8609 , 1096-8652
    URL: Issue
    Language: English
    Publisher: Wiley
    Publication Date: 2021
    detail.hit.zdb_id: 1492749-4
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 3
    Online Resource
    Online Resource
    Acta Physica Sinica, Chinese Physical Society and Institute of Physics, Chinese Academy of Sciences ; 2024
    In:  Acta Physica Sinica Vol. 73, No. 7 ( 2024), p. 072801-
    In: Acta Physica Sinica, Acta Physica Sinica, Chinese Physical Society and Institute of Physics, Chinese Academy of Sciences, Vol. 73, No. 7 ( 2024), p. 072801-
    Abstract: Neutron capture reaction is one of the neutron reactions and plays an important role in using reactor control rods and shell materials, designing nuclear device structures, and studying nuclear astrophysics S processes and element origins. The 4π BaF 〈 sub 〉 2 〈 /sub 〉 detection device has advantages such as high time resolution, low neutron sensitivity, and high detection efficiency, thus making it suitable for measuring neutron radiation capture reaction cross-section data. In order to fill the gap in our neutron capture reaction data in the keV energy range and improve their accuracy, the Key Laboratory of Nuclear Data at the Chinese Institute of Atomic Energy (CIAE) has established a Gamma Total Absorption Facility (GTAF), which consists of 28 hexagonal BaF 〈 sub 〉 2 〈 /sub 〉 crystals and 12 pentagonal BaF 〈 sub 〉 2 〈 /sub 〉 crystals to form a spherical shell with an external diameter of 25 cm and an internal diameter of 10 cm, covering 95.2% of the solid angles. The Back-n beam line of the Chinese Spallation Neutron Source (CSNS) is a back-streaming white beam line that covers neutron energy ranging from a few eV to several hundred MeV, making it suitable for measuring neutron capture cross-sections. The reaction cross-section data of 〈 sup 〉 197 〈 /sup 〉 Au is measured by using GTAF on the Back-n beam line. The measurement data are preliminarily background deducted through energy screening, PSD method, and crystal multiplicity screening. Subsequently, the background is analyzed and deducted based on the measurement data of 〈 sup 〉 nat 〈 /sup 〉 C and empty samples, and the yield of 〈 sup 〉 197 〈 /sup 〉 Au capture reaction is obtained. Resonance parameters are a set of parameters extracted from experimental data to describe the resonance curve, which can eliminate the influence of experimental conditions on resonance data and are more important than the cross-section obtained from experiments. The resonance energy, neutron resonance width, and gamma resonance width parameters of 〈 sup 〉 197 〈 /sup 〉 Au at 1–100 eV are fitted by using the SAMMY program. From the comparison between the resonance curves obtained from experimental measurements and the resonance parameters obtained from fitting with the ENDF/B-VIII.0 database, it can follow that the experimental measurement results are in good agreement with the database, nevertheless, there exist some differences in the resonance parameter, which may be due to the GTAF energy resolution, Back-n neutron spectrum measurement accuracy, and the experimental background deduction method. Our next work is to identify the sources of difference.
    Type of Medium: Online Resource
    ISSN: 1000-3290 , 1000-3290
    Language: Unknown
    Publisher: Acta Physica Sinica, Chinese Physical Society and Institute of Physics, Chinese Academy of Sciences
    Publication Date: 2024
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 4
    In: Science Bulletin, Elsevier BV, Vol. 68, No. 18 ( 2023-09), p. 2106-2114
    Type of Medium: Online Resource
    ISSN: 2095-9273
    Language: English
    Publisher: Elsevier BV
    Publication Date: 2023
    detail.hit.zdb_id: 2069521-4
    detail.hit.zdb_id: 2816140-3
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 5
    Online Resource
    Online Resource
    Acta Physica Sinica, Chinese Physical Society and Institute of Physics, Chinese Academy of Sciences ; 2020
    In:  Acta Physica Sinica Vol. 69, No. 17 ( 2020), p. 172901-
    In: Acta Physica Sinica, Acta Physica Sinica, Chinese Physical Society and Institute of Physics, Chinese Academy of Sciences, Vol. 69, No. 17 ( 2020), p. 172901-
    Abstract: The back-streaming neutron beam line (Back-n) was built in the beginning of 2018, which is part of the China Spallation Neutron Source (CSNS). The Back-n is the first white neutron beam line in China, and its main application is for nuclear data measurement. For most of neutron-induced nuclear reaction measurements based on white neutron facilities, the beam of gamma rays accompanied with neutron beam is one of the most important experimental backgrounds. The back streaming neutron beam is transported directly from the spallation target to the experimental station without any moderator or shielding, the flux of the in-beam gamma rays in the experimental station is much larger than those of these facilities with neutron moderator and shielding. Therefore, it is necessary to consider the influence of in-beam gamma rays on the experimental results. Studies of the in-beam gamma rays are carried out at the back-n. Monte-Carlo simulation is employed to obtain the energy distribution and the time structure of the in-beam gamma rays. According to the simulation results, when the neutron flight time is longer than 1.0 μs the energy distribution of the in-beam gamma rays does not vary with flight time. Therefore, the time structure of these gamma rays can be measured without the correction of the detection efficiency. In this work, the time structure of the in-beam gamma rays in the low neutron energy region is measured by both direct and indirect methods. In the direct measurement, a 〈sup〉6〈/sup〉Li loaded ZnS(Ag) scintillator is located on the neutron beam line and the time of flight method is used to determine the time structure of neutrons and gamma rays. The gamma rays are separated from neutrons with pulse-shape discrimination. The black filter method is used to verify the particle discrimination results. In the indirect measurement, the C〈sub〉6〈/sub〉D〈sub〉6〈/sub〉 scintillation detectors are used to measure the gamma rays scattered off a Pb sample on the way of the neutron beam. The time structure of the in-beam gamma rays is derived from that of the scattered gamma rays. The experimental results are in good agreement with the simulations with the time-of-flight between 12 μs and 2.0 ms. Besides, according to the simulation results, the intensity of the in-beam gamma rays is 1.21 × 10〈sup〉6〈/sup〉 s〈sup〉–1〈/sup〉·cm〈sup〉–2〈/sup〉 in the center of the experimental station 2 of Back-n, which is 76.5 m away from the spallation target of CSNS.
    Type of Medium: Online Resource
    ISSN: 1000-3290 , 1000-3290
    Language: Unknown
    Publisher: Acta Physica Sinica, Chinese Physical Society and Institute of Physics, Chinese Academy of Sciences
    Publication Date: 2020
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 6
    Online Resource
    Online Resource
    Acta Physica Sinica, Chinese Physical Society and Institute of Physics, Chinese Academy of Sciences ; 2021
    In:  Acta Physica Sinica Vol. 70, No. 8 ( 2021), p. 082901-
    In: Acta Physica Sinica, Acta Physica Sinica, Chinese Physical Society and Institute of Physics, Chinese Academy of Sciences, Vol. 70, No. 8 ( 2021), p. 082901-
    Abstract: At present, there exist few proton-beam terminals for the detector calibration in the world. Meanwhile, most of these terminals provide monoenergetic protons. Back-n white neutron source from China Spallation Neutron Source(CSNS) was put into operation in 2018. Based on the white neutron flux ranging from 0.5 eV to 200 MeV from the CSNS Back-n white neutron source, continuous-energy protons involved in a wide energy spectrum can be acquired from the 〈sup〉1〈/sup〉H(n, el) reaction. Adopting this method, a new research platform for researches such as proton calibration is realized at CSNS. As hydrogen exists as gas at normal temperature and pressure, in the selecting of the proton-converting target, the hydrogen-rich compounds are preferential considered. Considering the reaction cross sections of the 〈sup〉1〈/sup〉H(n, el), 〈sup〉12〈/sup〉C(n, p)〈sup〉12〈/sup〉B, 〈sup〉12〈/sup〉C(n, d)〈sup〉11〈/sup〉B, 〈sup〉12〈/sup〉C(n, t)〈sup〉10〈/sup〉B, 〈sup〉12〈/sup〉C(n, 〈sup〉3〈/sup〉He)〈sup〉10〈/sup〉Be, 〈sup〉12〈/sup〉C(n, α)〈sup〉9〈/sup〉Be and 〈sup〉1〈/sup〉H(n, γ)〈sup〉2〈/sup〉H, polyethylene and polypropylene are suitable for serving as targets in this research. Based on a 3U PXIe, digitizers with 1 GSps sampling rate and 12 bit resolution are utilized to digitize and record the output signals of telescopes. The time and amplitude information of each signal are extracted from its recorded waveform. Proton fluxes can be calculated by using the neutron energy spectrum and the cross section of the 〈sup〉1〈/sup〉H(n, el) reaction. Using the γ-flash event as the starting time of the time-of-flight (TOF) and the time information of signal in detector as the stopping time, the kinematic energy of each secondary proton can be deduced from the TOF and the angle of the detector. A calibration experiment on three charged particle telescopes, with each telescope consisting of a silicon detector and a CsI(Tl) detector, is carried out on this research platform. The readout methods of the CsI(Tl) detectors in these three telescopes are different. In the calibration experiment, Δ〈i〉E-〈/i〉〈i〉E〈/i〉 two-dimensional spectra and amplitude-〈i〉E〈/i〉〈sub〉p〈/sub〉 two-dimensional spectra of these telescopes are obtained. Through comparing these particle identification spectra, the SiPM is chosen as the signal readout method for CsI(Tl) detectors in the charged particle telescopes. These researches provide experimental evidence for the construction of the charged particle telescope at Back-n, and also illustrate the feasibility of wide-energy spectrum proton calibration based on the Back-n white neutron source.
    Type of Medium: Online Resource
    ISSN: 1000-3290 , 1000-3290
    Language: Unknown
    Publisher: Acta Physica Sinica, Chinese Physical Society and Institute of Physics, Chinese Academy of Sciences
    Publication Date: 2021
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 7
    Online Resource
    Online Resource
    Acta Physica Sinica, Chinese Physical Society and Institute of Physics, Chinese Academy of Sciences ; 2021
    In:  Acta Physica Sinica Vol. 70, No. 22 ( 2021), p. 222801-
    In: Acta Physica Sinica, Acta Physica Sinica, Chinese Physical Society and Institute of Physics, Chinese Academy of Sciences, Vol. 70, No. 22 ( 2021), p. 222801-
    Abstract: The data of neutron capture cross section are very important for the research of nuclear astrophysics, advanced nuclear energy development. Owing to the limitation of neutron source and detector, the experimental data of neutron capture cross section in an energy range of 1 eV–10 keV were almost blank in China. The first Chinese gamma-ray total absorption facility has been constructed in the key laboratory of nuclear data at China institute of atomic energy, which consists of 40 BaF〈sub〉2〈/sub〉 detector units. The BaF〈sub〉2〈/sub〉 crystal shell with a thickness of 15 cm and an inner radius of 10 cm covers 95.2% of the solid angle. On-line measurement method of neutron capture reaction cross section is established on the back-streaming white neutron source of China spallation neutron source by using the upgraded facility. The cross section of 〈sup〉197〈/sup〉Au neutron capture reaction is measured for the first time under the experimental condition of irregular 30 mm neutron beam spot. The measured position of resonance peak is well consistent with the relevant data of ENDF evaluation database, which verifies the reliability of the measurement device and measurement technology, and thus laying the foundation for the acquisition of high precision cross section in future.
    Type of Medium: Online Resource
    ISSN: 1000-3290 , 1000-3290
    Language: Unknown
    Publisher: Acta Physica Sinica, Chinese Physical Society and Institute of Physics, Chinese Academy of Sciences
    Publication Date: 2021
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 8
    In: The Astrophysical Journal, American Astronomical Society, Vol. 935, No. 1 ( 2022-08-01), p. 10-
    Abstract: One month after launching the Gravitational Wave High-energy Electromagnetic Counterpart All-sky Monitor, a bright thermonuclear X-ray burst from 4U 0614+09 was observed on 2021 January 24. We report the time-resolved spectroscopy of the burst and a hint of burst oscillation at 413 Hz with a fractional amplitude ∼2.0% (rms). This coincides with the burst oscillation previously discovered with Swift/Burst Alert Telescope (Strohmayer et al. 2008), and therefore supports the spin frequency of this source. This burst is a bright one in the normal bursts detected from 4U 0614+09, which leads to an upper limit of distance estimation of 3.1 kpc. The folded light curve during the burst oscillation shows a sinusoidal structure, which is consistent with previous observations.
    Type of Medium: Online Resource
    ISSN: 0004-637X , 1538-4357
    RVK:
    Language: Unknown
    Publisher: American Astronomical Society
    Publication Date: 2022
    detail.hit.zdb_id: 2207648-7
    detail.hit.zdb_id: 1473835-1
    SSG: 16,12
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 9
    In: HemaSphere, Ovid Technologies (Wolters Kluwer Health), Vol. 7, No. S3 ( 2023-08), p. e1182717-
    Type of Medium: Online Resource
    ISSN: 2572-9241
    Language: English
    Publisher: Ovid Technologies (Wolters Kluwer Health)
    Publication Date: 2023
    detail.hit.zdb_id: 2922183-3
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 10
    In: Blood, American Society of Hematology, Vol. 138, No. Supplement 1 ( 2021-11-05), p. 13-13
    Abstract: Introduction Immune thrombocytopenia (ITP) is an acquired, organ-specific, autoimmune disease and one of the most common bleeding disorders seriously endangering human health. Glucocorticoids and intravenous immunoglobulin are first-line treatments recommended by guidelines for patients with ITP. However, approximately 50%-85% of patients relapse during the first year of treatment. In addition, long-term use of glucocorticoids increases the risk for dose- and time-dependent glucocorticoid-related complications and serious side effects. Therefore, in-depth studies investigating new solutions for the first-line treatment of ITP are urgently needed. Tacrolimus is a calcineurin inhibitor, which forms a complex by binding to FK506-binding protein. It is currently widely used in the prevention of graft-versus-host disease for organ transplantation as well as for the treatment of autoimmune diseases. In addition to recent retrospective studies and case reports demonstrating its effectiveness in ITP, tacrolimus has been shown to improve anti-platelet antibody-mediated thrombocytopenia in mice, suggesting it may be a potential treatment for ITP. The aim of this study was to compare two first-line treatment options for ITP-a standard glucocorticoid-only regimen versus tacrolimus in combination with a standard glucocorticoid regimen-to determine which could help patients achieve stable platelet counts faster and experience a longer duration of remission. Methods This open-label, randomized, phase 2 trial, enrolled adult ITP patients from seven different tertiary medical centers in China. Elderly patients had confirmed, newly diagnosed, treatment-naive ITP, platelet counts & lt;30×10 9/L, or & lt; 50×10 9/L and significant bleeding symptoms (World Health Organization bleeding scale ≥ 2). Eligible patients were randomly assigned 1:1 with an interactive web-based response system to receive either oral tacrolimus (initial 0.03 mg/kg/day and maintain blood concentration at 3-5 ng/mL for 12 weeks) plus high-dose dexamethasone (HD-DXM) or HD-DXM monotherapy for 12 weeks. DXM (40 mg) was administered orally daily for 4 consecutive days to both study arms. The 4-day course of DXM was repeated on days 11-14 in patients who lacked response by day 10. The primary endpoint was 6-month sustained response (SR), defined as platelet count maintained & gt;50×10 9/L without any additional ITP-modifying therapy at the 6-month follow-up. Key secondary endpoints included initial response by day 14 (OR, platelet count ≥30×10 9/L and at least 2-fold increase in baseline platelet count and absence of bleeding; and CR, platelet count ≥ 100×10 9/L), duration of response, bleeding scores, and adverse events (AEs). This trial was registered with ClinicalTrials.gov (NCT04747080). Results Total 140 patients newly diagnosed with ITP were randomly assigned to either the tacrolimus plus HD-DXM (n=72) or HD-DXM monotherapy (n=68) groups. At the 6-month follow-up, the proportion of patients exhibiting SR was significantly higher in the tacrolimus plus HD-DXM group than in the HD-DXM monotherapy group (65.3% vs 42.6%, p= 0.007). Of the 140 patients with ITP (males accounted for 48.6%), the mean age was 32.8 years, the mean platelet count was 16.7×10 9/L. The combination group exhibited a higher 14-day early remission rate than the monotherapy group (76.4% vs 55.9%, P=0.001). Significantly fewer treatment failures occurred in patients randomly assigned to the combination group(19.4% vs 38.2%, P=0.0014). During the follow-up period, fewer patients in the combination group experienced relapse than in the monotherapy group; the median time to relapse was 77 days (Tacrolimus+HD-DXM) vs 36 days (HD-DXM). The combination group exhibited a lower proportion of bleeding events and a lower bleeding score. The incidence of serious AEs, rescue therapy, and treatment side effects were similar between the two groups, and treatment was well tolerated by all patients, with no grade 4 AEs or treatment-related deaths reported. There was no statistically significant difference in the incidence of treatment-related AEs between the two groups. Conclusions Low-dose tacrolimus plus HD-DXM was an effective and safe treatment for ITP as first-line therapy and elicited a sustained prolonged response in adults. This therapy may be a new treatment option for adult patients with ITP. Disclosures No relevant conflicts of interest to declare. OffLabel Disclosure: It includes information or discussion of off-label drug use of tacrilimus.
    Type of Medium: Online Resource
    ISSN: 0006-4971 , 1528-0020
    RVK:
    RVK:
    Language: English
    Publisher: American Society of Hematology
    Publication Date: 2021
    detail.hit.zdb_id: 1468538-3
    detail.hit.zdb_id: 80069-7
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...