GLORIA

GEOMAR Library Ocean Research Information Access

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    In: American Journal of Respiratory and Critical Care Medicine, American Thoracic Society, Vol. 201, No. 11 ( 2020-06-01), p. 1389-1397
    Type of Medium: Online Resource
    ISSN: 1073-449X , 1535-4970
    RVK:
    Language: English
    Publisher: American Thoracic Society
    Publication Date: 2020
    detail.hit.zdb_id: 1468352-0
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 2
    In: Critical Care Medicine, Ovid Technologies (Wolters Kluwer Health), Vol. 49, No. 10 ( 2021-10), p. 1779-1789
    Abstract: To describe mechanical ventilation management and factors associated with nonadherence to lung-protective ventilation principles in pediatric acute respiratory distress syndrome. DESIGN: A planned ancillary study to a prospective international observational study. Mechanical ventilation management (every 6 hr measurements) during pediatric acute respiratory distress syndrome days 0–3 was described and compared with Pediatric Acute Lung Injury Consensus Conference tidal volume recommendations ( 〈 7 mL/kg in children with impaired respiratory system compliance, 〈 9 mL/kg in all other children) and the Acute Respiratory Distress Syndrome Network lower positive end-expiratory pressure/higher F io 2 grid recommendations. SETTING: Seventy-one international PICUs. PATIENTS: Children with pediatric acute respiratory distress syndrome. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: Analyses included 422 children. On pediatric acute respiratory distress syndrome day 0, median tidal volume was 7.6 mL/kg (interquartile range, 6.3–8.9 mL/kg) and did not differ by pediatric acute respiratory distress syndrome severity. Plateau pressure was not recorded in 97% of measurements. Using delta pressure (peak inspiratory pressure – positive end-expiratory pressure), median tidal volume increased over quartiles of median delta pressure ( p = 0.007). Median delta pressure was greater than or equal to 18 cm H 2 O for all pediatric acute respiratory distress syndrome severity levels. In severe pediatric acute respiratory distress syndrome, tidal volume was greater than or equal to 7 mL/kg 62% of the time, and positive end-expiratory pressure was lower than recommended by the positive end-expiratory pressure/F io 2 grid 70% of the time. In multivariable analysis, tidal volume nonadherence was more common with severe pediatric acute respiratory distress syndrome, fewer PICU admissions/yr, non-European PICUs, higher delta pressure, corticosteroid use, and pressure control mode. Adherence was associated with underweight stature and cuffed endotracheal tubes. In multivariable analysis, positive end-expiratory pressure/F io 2 grid nonadherence was more common with higher pediatric acute respiratory distress syndrome severity, ventilator decisions made primarily by the attending physician, pre-ICU cardiopulmonary resuscitation, underweight stature, and age less than 2 years. Adherence was associated with respiratory therapist involvement in ventilator management and longer time from pediatric acute respiratory distress syndrome diagnosis. Higher nonadherence to tidal volume and positive end-expiratory pressure recommendations were independently associated with higher mortality and longer duration of ventilation after adjustment for confounding variables. In stratified analyses, these associations were primarily influenced by children with severe pediatric acute respiratory distress syndrome. CONCLUSIONS: Nonadherence to lung-protective ventilation principles is common in pediatric acute respiratory distress syndrome and may impact outcome. Modifiable factors exist that may improve adherence.
    Type of Medium: Online Resource
    ISSN: 0090-3493
    Language: English
    Publisher: Ovid Technologies (Wolters Kluwer Health)
    Publication Date: 2021
    detail.hit.zdb_id: 2034247-0
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 3
    In: Critical Care Medicine, Ovid Technologies (Wolters Kluwer Health), Vol. 48, No. 6 ( 2020-06), p. e514-e522
    Abstract: Pediatric acute respiratory distress syndrome is heterogeneous, with a paucity of risk stratification tools to assist with trial design. We aimed to develop and validate mortality prediction models for patients with pediatric acute respiratory distress syndrome. Design: Leveraging additional data collection from a preplanned ancillary study (Version 1) of the multinational Pediatric Acute Respiratory Distress syndrome Incidence and Epidemiology study, we identified predictors of mortality. Separate models were built for the entire Version 1 cohort, for the cohort excluding neurologic deaths, for intubated subjects, and for intubated subjects excluding neurologic deaths. Models were externally validated in a cohort of intubated pediatric acute respiratory distress syndrome patients from the Children’s Hospital of Philadelphia. Setting: The derivation cohort represented 100 centers worldwide; the validation cohort was from Children’s Hospital of Philadelphia. Patients: There were 624 and 640 subjects in the derivation and validation cohorts, respectively. Interventions: None. Measurements and Main Results: The model for the full cohort included immunocompromised status, Pediatric Logistic Organ Dysfunction 2 score, day 0 vasopressor-inotrope score and fluid balance, and Pa o 2 /F io 2 6 hours after pediatric acute respiratory distress syndrome onset. This model had good discrimination (area under the receiver operating characteristic curve 0.82), calibration, and internal validation. Models excluding neurologic deaths, for intubated subjects, and for intubated subjects excluding neurologic deaths also demonstrated good discrimination (all area under the receiver operating characteristic curve ≥ 0.84) and calibration. In the validation cohort, models for intubated pediatric acute respiratory distress syndrome (including and excluding neurologic deaths) had excellent discrimination (both area under the receiver operating characteristic curve ≥ 0.85), but poor calibration. After revision, the model for all intubated subjects remained miscalibrated, whereas the model excluding neurologic deaths showed perfect calibration. Mortality models also stratified ventilator-free days at 28 days in both derivation and validation cohorts. Conclusions: We describe predictive models for mortality in pediatric acute respiratory distress syndrome using readily available variables from day 0 of pediatric acute respiratory distress syndrome which outperform severity of illness scores and which demonstrate utility for composite outcomes such as ventilator-free days. Models can assist with risk stratification for clinical trials.
    Type of Medium: Online Resource
    ISSN: 0090-3493
    Language: English
    Publisher: Ovid Technologies (Wolters Kluwer Health)
    Publication Date: 2020
    detail.hit.zdb_id: 2034247-0
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...