In:
Key Engineering Materials, Trans Tech Publications, Ltd., Vol. 592-593 ( 2013-11), p. 258-261
Abstract:
This paper presents the calibration of three universal ductile fracture criteria with the stress triaxiality and the normalized third invariant of deviatoric stress dependence. Xue-Wierzbicki, Bai-Wierzbicki and Extended Mohr-Coulomb criteria are calibrated using butterfly specimen and newly designed notched tube specimen for an austenitic stainless steel. Different stress states necessary for successful calibration are generated by suitable combination of tension/compression-shear or tension/compression-torsion loading of both specimens, respectively. Suitability of the specimens for ductile fracture criteria calibration is evaluated comparing the range of reached stress states, the homogeneity of stress in process zone and appropriateness for the computational simulation of tests. Possible combination of above mentioned results with tensile testing of standard and notched cylindrical specimens is discussed, too.
Type of Medium:
Online Resource
ISSN:
1662-9795
DOI:
10.4028/www.scientific.net/KEM.592-593
DOI:
10.4028/www.scientific.net/KEM.592-593.258
Language:
Unknown
Publisher:
Trans Tech Publications, Ltd.
Publication Date:
2013
detail.hit.zdb_id:
2073306-9
Permalink