    In: Applied Sciences, MDPI AG, Vol. 12, No. 17 ( 2022-09-04), p. 8881-
    Abstract: Strain elastography (SE) determines the level of tissue stiffness and thus helps in the diagnosis and differentiation of various pathologies. This paper aims to study the elastographic differences between healthy thyroid parenchyma and ones affected by chronic autoimmune thyroiditis (CAT) in children. We included in our study 52 children diagnosed with CAT and 22 children with no thyroid pathology. After clinic examination and biological tests, an ultrasound was performed followed by SE using a Hitachi Preirus machine with a 5–15 multi-frequency linear probe. The mean strain ratio (SR) values were significantly lower in the control group compared with the CAT group (0.68 ± 0.2 vs. 1.19 ± 0.25; p 〈 0.0001). A mean value above 0.9 was found predictive for CAT with 84.62% Sensitivity(Se), 95.45% Specificity (Sp), 97.8% Positive Predictive Value (PPV), 72.4% Negative Predictive Value (NPV), and area under receiver operating characteristic (AUROC), 0.9. No differences were found between the two thyroid lobes. Also, we found no differences between girls and boys. Out of the 52 children with CAT, 39 were on therapy with levothyroxine. No differences were found between SR values in preexisting hypothyroid cases compared to euthyroid cases (1.24 ± 0.26 vs. 1.18 ± 0.25; p = 0.4615). Our results show that SE is a useful examination technique of children diagnosed with CAT, in accordance with other studies conducted on adults. This study lays the foundation for elastographic examination among children.
    Type of Medium: Online Resource
    ISSN: 2076-3417
    Language: English
    Publisher: MDPI AG
    Publication Date: 2022
    detail.hit.zdb_id: 2704225-X
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 2
    In: Applied Sciences, MDPI AG, Vol. 12, No. 21 ( 2022-11-03), p. 11147-
    Abstract: The aim of this study is to assess the diagnostic performance of strain elastography (SE) versus 2D shear-wave elastography (2D-SWE) by providing a head-to-head comparison of the two methods. Ninety-four thyroid nodules were evaluated using conventional ultrasound (B-mode) and SE, namely, real-time elastography (RTE) with a Hitachi Preirus machine (Hitachi Inc., Tokyo, Japan) and consecutively, 2D-SWE with SuperSonic Mach30 equipment (Supersonic Imagine, Aix-en-Provence, France). The results were compared in all cases to the pathology reports. Out of the 94 nodules, 29 (30.9%) were malignant. Both SE and 2D-SWE parameters proved to have excellent diagnostic quality, with comparable results. The mean elasticity index was the best parameter for the 2D-SWE (AUC 0.912); for a cut-off value of 30.5 kPa, it predicts thyroid malignancy with a sensitivity of 79.3%, specificity of 95.38%, NPV of 91.2% and PPV of 88.5%. The best parameter for SE was the strain ratio (cutoff 〉 3.9; sensitivity 82.7%; specificity 92.3%; AUC 0.905). When integrated in the ultrasound risk algorithm, both elastography methods improved the diagnostic performance: AUC 0.764 vs. 0.886 vs. 0.861 for B-modes: B-mode + 2D-SWE vs. B-mode + SE. We concluded that elastography adds diagnostic value in predicting malignancy, both when Hitachi RTE and SuperSonic 2D-SWE were used.
    Type of Medium: Online Resource
    ISSN: 2076-3417
    Language: English
    Publisher: MDPI AG
    Publication Date: 2022
    detail.hit.zdb_id: 2704225-X
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 3
    In: Biomedicines, MDPI AG, Vol. 11, No. 3 ( 2023-03-17), p. 938-
    Abstract: The estimation of viscosity by measuring the shear-wave dispersion (SWD) using ultrasound 2D shear-wave elastography (SWE) is becoming more and more popular. Recent research suggests that SWD can be used in addition to 2D-SWE (shear-wave speed) to diagnose diffuse liver disease. Viscosity was studied for the assessment of normal thyroid tissue. This study aims to evaluate the use of viscosity measurements in patients with chronic autoimmune thyroiditis using the SuperSonic MACH®30 ultrasound machine (Hologic SuperSonic Imagine, Aix-en-Provence, France) which provides the Vi PLUS mode for viscosity and the 2D SWE PLUS mode for shear-wave speed measurements. Valid measurements were obtained in 308 cases, 153 with chronic autoimmune thyroiditis (CAT) and 155 with no thyroid pathology (95.95% feasibility of the methods). The differences between the healthy group and the CAT group were statistically significant both for Vi PLUS (2.5 ± 0.4 vs. 2.8 ± 0.5, p 〈 0.0001) and for 2D-SWE PLUS (13.5 ± 3.3 vs. 23.1 ± 8.3, p 〈 0.0001). The diagnostic performance was poor for Vi PLUS alone (AUC = 0.69; cut-off 〉 2.5 Pa·s, se = 68.6%; sp = 64.52%) and good for 2D-SWE PLUS alone (AUC = 0.861; cut-off 〉 18.4 kPa, se = 69.9%; sp = 92.2%). Vi PLUS correlated with 2D-SWE PLUS, with the presence of CAT, the thyroid volume, levothyroxine replacement therapy and age. Statistically significant differences were found between the CAT subgroup receiving thyroid replacement therapy and the subgroup without therapy: 24.74 ± 8.33 vs. 21.93 ± 8.12 kPa for 2D-SWE (p = 0.0380) and 3 ± 0.5 vs. 2.7 ± 0.4 Pa·s for Vi PLUS (p = 0.0193). Elastography-based methods improve the classic ultrasound evaluation: 2D-SWE PLUS performed somewhat better in distinguishing CAT from normal thyroid tissue, while Vi PLUS made a slightly better assessment regarding the functional status.
    Type of Medium: Online Resource
    ISSN: 2227-9059
    Language: English
    Publisher: MDPI AG
    Publication Date: 2023
    detail.hit.zdb_id: 2720867-9
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 4
    In: Biomedicines, MDPI AG, Vol. 11, No. 7 ( 2023-06-26), p. 1841-
    Abstract: Obese children present a higher cardio-metabolic risk. Measuring vascular biomarkers that assess the evolution of arterial stiffness, subclinical atherosclerosis, and hypertension in such patients could be helpful in the long term. We studied 84 children, aged from 6 to 18 years: 50 obese subjects, versus 34 of normal weight. Clinical examination involved: BMI, waist circumference, waist-to-height ratio, and detection of the presence of acanthosis nigricans and irregular menstrual cycles (the latter in adolescent girls). The carotid intima-media thickness (CIMT) was measured with the Aixplorer MACH 30 echography device. The pulse wave velocity (PWV), augmentation index (AIx), and peripheral and central blood pressures (i.e., SBP, DBP, cSBP, cDBP, and cPP) were acquired through a Mobil-O-Graph device. Obese subjects underwent body composition analysis with a Tanita BC-418. Blood tests were: HOMA-IR, lipid panel, uric acid, and 25-OH vitamin D. All vascular biomarkers presented increased values in obese subjects versus controls. The following cut-off values were significant in detecting obesity: for PWV 〉 4.6 m/s, cSBP 〉 106 mmHg for the 〈 12-year-olds, PWV 〉 4.5 m/s and cSBP 〉 115 mmHg for the 12–15-year-olds, and PWV 〉 5 m/s, cSBP 〉 123 mmHg for the 〉 15-year-olds. AIx is higher in obese children, regardless of their insulin resistance status. Waist circumference and waist-to-height ratio correlate to all vascular parameters. HOMA-IR is an independent predictor for all vascular parameters except CIMT. Cut-off values for PWV of 〉 4.8 m/s, SBP 〉 125 mmHg, and a cSBP 〉 117 mmHg predicted the presence of acanthosis nigricans. Obese girls with irregular menses displayed significantly higher PWV, SBP, and DPB. Elevated levels of uric acid, LDL-c, non-LDL-c, triglycerides, and transaminases, and low levels of HDL-c and 25-OH vitamin D correlated with higher arterial stiffness and CIMT values. We conclude that CIMT and the markers of arterial stiffness are useful in the early detection of vascular damage in obese children.
    Type of Medium: Online Resource
    ISSN: 2227-9059
    Language: English
    Publisher: MDPI AG
    Publication Date: 2023
    detail.hit.zdb_id: 2720867-9
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 5
    In: Biomedicines, MDPI AG, Vol. 10, No. 11 ( 2022-11-08), p. 2859-
    Abstract: Introduction: There is currently a lack of published data on kidney elasticity and viscosity. Non-invasive techniques, such as two-dimensional shear-wave elastography (2D-SWE PLUS) and viscosity plane-wave ultrasound (Vi PLUS), have surfaced as new detection methods, which, thanks to efficient processing software, are expected to improve renal stiffness and viscosity measurements. This study aims to be the first one to assess the normal range values in normal renal function subjects and to investigate the factors that impact them. Methods: We conducted a cross-sectional study employing 50 participants (29 women and 21 men) with a mean age of 42.22 ± 13.17, a mean estimated glomerular filtration rate (eGFR) of 97.12 ± 11 mL/min/1.73 m2, a mean kidney length of 10.16 ± 0.66 cm, and a mean body mass index (BMI) of 24.24 ± 3.98. With a C6-1X convex transducer and the Ultra-FastTM software available on the Hologic Aixplorer Mach 30 ultrasound system, we acquired five measurements of renal cortical stiffness and viscosity (achieved from five distinct images in the middle part of the subcapsular cortex) from each kidney. The ten measurements’ median values correlated with the participant’s demographical, biological, and clinical parameters. Results: The mean kidney elasticity was 31.88 ± 2.89 kiloPascal (kPa), and the mean viscosity was 2.44 ± 0.57 Pascal.second (Pa.s) for a mean measurement depth 4.58 ± 1.02 cm. Renal stiffness seemed to be influenced by age (r = −0.7047, p 〈 0.0001), the measurement depth (r = −0.3776, p = 0.0075), and eGFR (r = 0.6101, p 〈 0.0001) but not by BMI (r = −0.2150, p = 0.1338), while viscosity appeared to be impacted by age (r = −0.4251, p = 0.0021), eGFR (r = 0.4057, p = 0.0038), the measurement depth (r = −0.4642, p = 0.0008), and BMI (r = −0.3676, p = 0.0086). The results of the one-way ANOVA used to test the differences in the variables among the three age sub-groups are statistically significant for both 2D-SWE PLUS (p 〈 0.001) and Vi PLUS (p = 0.015). The method found good intra-operator reproducibility for the 2D-SWE PLUS measurements, with an ICC of 0.8365 and a 95% CI of 0.7512 to 0.8990, and for the Vi PLUS measurements, with an ICC of 0.9 and a 95% CI of 0.8515 to 0.9397. Conclusions: Renal stiffness and viscosity screening may become an efficacious, low-cost way to gather supplemental diagnostic data from patients with chronic kidney disease (CKD). The findings demonstrate that these non-invasive methods are highly feasible and not influenced by gender and that their values correlate with renal function and decrease with age progression. Nevertheless, more research is required to ascertain their place in clinical practice.
    Type of Medium: Online Resource
    ISSN: 2227-9059
    Language: English
    Publisher: MDPI AG
    Publication Date: 2022
    detail.hit.zdb_id: 2720867-9
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 6
    Online Resource
    Online Resource
    Elsevier BV ; 2022
    In:  Ultrasound in Medicine & Biology Vol. 48 ( 2022), p. S45-
    In: Ultrasound in Medicine & Biology, Elsevier BV, Vol. 48 ( 2022), p. S45-
    Type of Medium: Online Resource
    ISSN: 0301-5629
    RVK:
    Language: English
    Publisher: Elsevier BV
    Publication Date: 2022
    detail.hit.zdb_id: 1498918-9
    SSG: 12
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 7
    Online Resource
    Online Resource
    Elsevier BV ; 2022
    In:  Ultrasound in Medicine & Biology Vol. 48 ( 2022), p. S28-
    In: Ultrasound in Medicine & Biology, Elsevier BV, Vol. 48 ( 2022), p. S28-
    Type of Medium: Online Resource
    ISSN: 0301-5629
    RVK:
    Language: English
    Publisher: Elsevier BV
    Publication Date: 2022
    detail.hit.zdb_id: 1498918-9
    SSG: 12
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 8
    Online Resource
    Online Resource
    Elsevier BV ; 2022
    In:  Ultrasound in Medicine & Biology Vol. 48 ( 2022), p. S17-
    In: Ultrasound in Medicine & Biology, Elsevier BV, Vol. 48 ( 2022), p. S17-
    Type of Medium: Online Resource
    ISSN: 0301-5629
    RVK:
    Language: English
    Publisher: Elsevier BV
    Publication Date: 2022
    detail.hit.zdb_id: 1498918-9
    SSG: 12
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 9
    Online Resource
    Online Resource
    Bioscientifica ; 2019
    In:  Endocrine Abstracts ( 2019-11-06)
    In: Endocrine Abstracts, Bioscientifica, ( 2019-11-06)
    Type of Medium: Online Resource
    ISSN: 1479-6848
    Language: Unknown
    Publisher: Bioscientifica
    Publication Date: 2019
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 10
    Online Resource
    Online Resource
    Bioscientifica ; 2020
    In:  Endocrine Abstracts ( 2020-08-21)
    In: Endocrine Abstracts, Bioscientifica, ( 2020-08-21)
    Type of Medium: Online Resource
    ISSN: 1479-6848
    Language: Unknown
    Publisher: Bioscientifica
    Publication Date: 2020
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...