GLORIA

GEOMAR Library Ocean Research Information Access

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    In: Scientific Reports, Springer Science and Business Media LLC, Vol. 11, No. 1 ( 2021-08-02)
    Abstract: Coronavirus disease 2019 (COVID-19) is caused by severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2) and is primarily characterised by a respiratory disease. However, SARS-CoV-2 can directly infect vascular endothelium and subsequently cause vascular inflammation, atherosclerotic plaque instability and thereby result in both endothelial dysfunction and myocardial inflammation/infarction. Interestingly, up to 50% of patients suffer from persistent exercise dyspnoea and a post-viral fatigue syndrome (PVFS) after having overcome an acute COVID-19 infection. In the present study, we assessed the presence of coronary microvascular disease (CMD) by cardiovascular magnetic resonance (CMR) in post-COVID-19 patients still suffering from exercise dyspnoea and PVFS. N = 22 patients who recently recovered from COVID-19, N = 16 patients with classic hypertrophic cardiomyopathy (HCM) and N = 17 healthy control patients without relevant cardiac disease underwent dedicated vasodilator-stress CMR studies on a 1.5-T MR scanner. The CMR protocol comprised cine and late-gadolinium-enhancement (LGE) imaging as well as velocity-encoded (VENC) phase-contrast imaging of the coronary sinus flow (CSF) at rest and during pharmacological stress (maximal vasodilation induced by 400 µg IV regadenoson). Using CSF measurements at rest and during stress, global myocardial perfusion reserve (MPR) was calculated. There was no difference in left ventricular ejection-fraction (LV-EF) between COVID-19 patients and controls (60% [57–63%] vs. 63% [60–66%] , p = NS). There were only N = 4 COVID-19 patients (18%) showing a non-ischemic pattern of LGE. VENC-based flow measurements showed that CSF at rest was higher in COVID-19 patients compared to controls (1.78 ml/min [1.19–2.23 ml/min] vs. 1.14 ml/min [0.91–1.32 ml/min] , p = 0.048). In contrast, CSF during stress was lower in COVID-19 patients compared to controls (3.33 ml/min [2.76–4.20 ml/min] vs. 5.32 ml/min [3.66–5.52 ml/min] , p = 0.05). A significantly reduced MPR was calculated in COVID-19 patients compared to healthy controls (2.73 [2.10–4.15–11] vs. 4.82 [3.70–6.68] , p = 0.005). No significant differences regarding MPR were detected between COVID-19 patients and HCM patients. In post-COVID-19 patients with persistent exertional dyspnoea and PVFS, a significantly reduced MPR suggestive of CMD—similar to HCM patients—was observed in the present study. A reduction in MPR can be caused by preceding SARS-CoV-2-associated direct as well as secondary triggered mechanisms leading to diffuse CMD, and may explain ongoing symptoms of exercise dyspnoea and PVFS in some patients after COVID-19 infection.
    Type of Medium: Online Resource
    ISSN: 2045-2322
    Language: English
    Publisher: Springer Science and Business Media LLC
    Publication Date: 2021
    detail.hit.zdb_id: 2615211-3
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 2
    Online Resource
    Online Resource
    Walter de Gruyter GmbH ; 2017
    In:  LaboratoriumsMedizin Vol. 41, No. 5 ( 2017-10-26), p. 205-213
    In: LaboratoriumsMedizin, Walter de Gruyter GmbH, Vol. 41, No. 5 ( 2017-10-26), p. 205-213
    Abstract: Die Arbeitsgruppe POCT der Deutschen Gesellschaft für Klinische Chemie und Laboratoriumsmedizin (DGKL) hat vom 13. bis 15. März 2017 das dritte Münchner Symposium zum Thema „Weiterentwicklung der patientennahen Sofortdiagnostik in unterschiedlichen klinischen Anwendungsbereichen“ organisiert. Unter der Kongressleitung von Prof. Dr. Peter B. Luppa, TU München wurden die Themenschwerpunkte von 43 Vortragenden behandelt. Dabei wurden insgesamt 9 Sitzungen von den Mitgliedern der Arbeitsgruppe POCT geleitet. Die Kongresssprachen waren Deutsch und Englisch. Eine angeschlossene Industrieausstellung mit 29 IVD-Unternehmen zeigte die neuesten POCT-Analysengeräte. Erstmals fand zudem eine ePosterausstellung mit 24 Postern in zwei eigenen Sessions statt. Dabei lagen die Poster elektronisch vor, der vorstellende Autor konnte es an einem speziellen Monitor allen Teilnehmern wie eine Bilderpräsentation vorführen. Neu war auch die Vergabe von 4 Vortrags- und 2 Posterpreisen.
    Type of Medium: Online Resource
    ISSN: 1439-0477 , 0342-3026
    Language: English
    Publisher: Walter de Gruyter GmbH
    Publication Date: 2017
    detail.hit.zdb_id: 2081704-6
    detail.hit.zdb_id: 2909042-8
    SSG: 15,3
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 3
    In: European Heart Journal – Cardiovascular Imaging, Oxford University Press (OUP), Vol. 17, No. 3 ( 2016-03), p. 326-333
    Type of Medium: Online Resource
    ISSN: 2047-2404 , 2047-2412
    Language: English
    Publisher: Oxford University Press (OUP)
    Publication Date: 2016
    detail.hit.zdb_id: 2042482-6
    detail.hit.zdb_id: 2647943-6
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 4
    In: Clinical Chemistry and Laboratory Medicine (CCLM), Walter de Gruyter GmbH, Vol. 56, No. 8 ( 2018-07-26), p. 1238-1250
    Abstract: Determination of blood glucose concentration is one of the most important measurements in clinical chemistry worldwide. Analyzers in central laboratories (CL) and point-of-care tests (POCT) are both frequently used. In Germany, regular participation in external quality assessment (EQA) schemes is mandatory for laboratories performing glucose testing. Methods: Glucose testing data from the two German EQAs “Reference Institute for Bioanalytics” (RfB) and “INSTAND – Gesellschaft zur Förderung der Qualitätssicherung in medizinischen Laboratorien” (Instand) were analyzed from 2012 to 2016. Multivariable odds ratios (OR) for the probability to reach a “good” result were calculated. Imprecision and bias were determined and clinical risk of measurement errors estimated. Results: The device employed was the most important variable required for a “good” performance in all EQAs. Additional participation in an EQA for CL automated analyzers improved performance in POCT EQAs. The reciprocal effect was less pronounced. New participants performed worse than experienced participants especially in CL EQAs. Imprecision was generally smaller for CL, but some POCT devices reached a comparable performance. Large lot-to-lot differences occurred in over 10% of analyzed cases. We propose the “bias budget” as a new metric to express the maximum allowable bias that still carries acceptable medical risk. Bias budgets were smallest and clinical risks of errors greatest in the low range of measurement 60–115 mg/dL (3.3–6.4 mmol/L) for most devices. Conclusions: EQAs help to maintain high analytical performances. They generate important data that serve as the foundation for learning and improvement in the laboratory healthcare system.
    Type of Medium: Online Resource
    ISSN: 1437-4331 , 1434-6621
    Language: Unknown
    Publisher: Walter de Gruyter GmbH
    Publication Date: 2018
    detail.hit.zdb_id: 1492732-9
    SSG: 15,3
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 5
    Online Resource
    Online Resource
    Springer Science and Business Media LLC ; 2018
    In:  Clinical Research in Cardiology Vol. 107, No. 11 ( 2018-11), p. 1062-1070
    In: Clinical Research in Cardiology, Springer Science and Business Media LLC, Vol. 107, No. 11 ( 2018-11), p. 1062-1070
    Type of Medium: Online Resource
    ISSN: 1861-0684 , 1861-0692
    RVK:
    Language: English
    Publisher: Springer Science and Business Media LLC
    Publication Date: 2018
    detail.hit.zdb_id: 2218331-0
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 6
    In: Clinical Research in Cardiology, Springer Science and Business Media LLC, Vol. 110, No. 1 ( 2021-01), p. 136-145
    Abstract: Coronary microvascular dysfunction (CMD) is present in various non-ischemic cardiomyopathies and in particular in those with left-ventricular hypertrophy. This study evaluated the diagnostic value of the novel cardiovascular magnetic resonance (CMR) parameter “myocardial transit-time” (MyoTT) in distinguishing cardiac amyloidosis from other hypertrophic cardiomyopathies. Methods N =  20 patients with biopsy-proven cardiac amyloidosis (CA), N =  20 patients with known hypertrophic cardiomyopathy (HCM), and N =  20 control patients without relevant cardiac disease underwent dedicated CMR studies on a 1.5-T MR scanner. The CMR protocol comprised cine and late-gadolinium-enhancement (LGE) imaging as well as first-pass perfusion acquisitions at rest for MyoTT measurement. MyoTT was defined as the blood circulation time from the orifice of the coronary arteries to the pooling in the coronary sinus (CS) reflecting the transit-time of gadolinium in the myocardial microvasculature. Results MyoTT was significantly prolonged in patients with CA compared to both groups: 14.8 ± 4.1 s in CA vs. 12.2 ± 2.5 s in HCM ( p =  0.043) vs. 7.2 ± 2.6 s in controls ( p   〈  0.001). Native T1 and extracellular volume (ECV) were significantly higher in CA compared to HCM and controls ( p   〈  0.001). Both parameters were associated with a higher diagnostic accuracy in predicting the presence of CA compared to MyoTT: area under the curve (AUC) for native T1 = 0.93 (95% confidence interval (CI) = 0.83–1.00; p   〈  0.001) and AUC for ECV = 0.95 (95% CI = 0.88–1.00; p   〈  0.001)—compared to the AUC for MyoTT = 0.76 (95% CI = 0.60–0.92; p =  0.008). In contrast, MyoTT performed better than all other CMR parameters in differentiating HCM from controls (AUC for MyoTT = 0.93; 95% CI = 0.81–1.00; p =  0.003 vs. AUC for native T1 = 0.69; 95% CI = 0.44–0.93; p =  0.20 vs. AUC for ECV = 0.85; 95% CI = 0.66–1.00; p =  0.017). Conclusion The relative severity of CMD (measured by MyoTT) in relationship to extracellular changes (measured by native T1 and/or ECV) is more pronounced in HCM compared to CA—in spite of a higher absolute MyoTT value in CA patients. Hence, MyoTT may improve our understanding of the interplay between extracellular/intracellular and intravasal changes that occur in the myocardium during the disease course of different cardiomyopathies.
    Type of Medium: Online Resource
    ISSN: 1861-0684 , 1861-0692
    RVK:
    Language: English
    Publisher: Springer Science and Business Media LLC
    Publication Date: 2021
    detail.hit.zdb_id: 2218331-0
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 7
    In: Clinical Research in Cardiology, Springer Science and Business Media LLC, Vol. 110, No. 4 ( 2021-04), p. 555-568
    Abstract: Cardiac amyloidosis (CA) is an infiltrative disease characterised by accumulation of amyloid deposits in the extracellular space of the myocardium—comprising transthyretin (ATTR) and light chain (AL) amyloidosis as the most frequent subtypes. Histopathological proof of amyloid deposits by endomyocardial biopsy (EMB) is the gold standard for diagnosis of CA. Cardiovascular magnetic resonance (CMR) allows non-invasive workup of suspected CA. We conducted a multi-centre study to assess the diagnostic value of CMR in comparison to EMB for the diagnosis of CA. Methods We studied N  = 160 patients characterised by symptoms of heart failure and presence of left ventricular (LV) hypertrophy of unknown origin who presented to specialised cardiomyopathy centres in Germany and underwent further diagnostic workup by both CMR and EMB. If CA was diagnosed, additional subtyping based on EMB specimens and monoclonal protein studies in serum was performed. The CMR protocol comprised cine- and late-gadolinium-enhancement (LGE)-imaging as well as native and post-contrast T1-mapping (in a subgroup)—allowing to measure extracellular volume fraction (ECV) of the myocardium. Results An EMB-based diagnosis of CA was made in N  = 120 patients (CA group) whereas N  = 40 patients demonstrated other diagnoses (CONTROL group). In the CA group, N  = 114 (95%) patients showed a characteristic pattern of LGE indicative of CA. In the CONTROL group, only 1/40 (2%) patient showed a “false-positive” LGE pattern suggestive of CA. In the CA group, there was no patient with elevated T1-/ECV-values without a characteristic pattern of LGE indicative of CA. LGE-CMR showed a sensitivity of 95% and a specificity of 98% for the diagnosis of CA. The combination of a characteristic LGE pattern indicating CA with unremarkable monoclonal protein studies resulted in the diagnosis of ATTR-CA (confirmed by EMB) with a specificity of 98% [95%-confidence interval (CI) 92–100%] and a positive predictive value (PPV) of 99% (95%-CI 92–100%), respectively. The EMB-associated risk of complications was 3.13% in this study—without any detrimental or persistent complications. Conclusion Non-invasive CMR shows an excellent diagnostic accuracy and yield regarding CA. When combined with monoclonal protein studies, CMR can differentiate ATTR from AL with high accuracy and predictive value. However, invasive EMB remains a safe invasive gold-standard and allows to differentiate CA from other cardiomyopathies that can also cause LV hypertrophy.
    Type of Medium: Online Resource
    ISSN: 1861-0684 , 1861-0692
    RVK:
    Language: English
    Publisher: Springer Science and Business Media LLC
    Publication Date: 2021
    detail.hit.zdb_id: 2218331-0
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 8
    In: JACC: Cardiovascular Imaging, Elsevier BV, ( 2023-9)
    Type of Medium: Online Resource
    ISSN: 1936-878X
    Language: English
    Publisher: Elsevier BV
    Publication Date: 2023
    detail.hit.zdb_id: 2412441-2
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 9
    Online Resource
    Online Resource
    Informa UK Limited ; 2016
    In:  International Journal of Nanomedicine Vol. Volume 11 ( 2016-07), p. 3191-3203
    In: International Journal of Nanomedicine, Informa UK Limited, Vol. Volume 11 ( 2016-07), p. 3191-3203
    Type of Medium: Online Resource
    ISSN: 1178-2013
    Language: English
    Publisher: Informa UK Limited
    Publication Date: 2016
    detail.hit.zdb_id: 2377464-2
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 10
    In: Scientific Reports, Springer Science and Business Media LLC, Vol. 11, No. 1 ( 2021-07-30)
    Abstract: Cardiac amyloidosis (CA) is an infiltrative disease. In the present study, we compared the diagnostic accuracy of cardiovascular magnetic resonance (CMR)-based T1-mapping and subsequent extracellular volume fraction (ECV) measurement and longitudinal strain analysis in the same patients with (a) biopsy-proven cardiac amyloidosis (CA) and (b) hypertrophic cardiomyopathy (HCM). N  = 30 patients with CA, N  = 20 patients with HCM and N  = 15 healthy control patients without relevant cardiac disease underwent dedicated CMR studies. The CMR protocol included standard sequences for cine-imaging, native and post-contrast T1-mapping and late-gadolinium-enhancement. ECV measurements were based on pre- and post-contrast T1-mapping images. Feature-tracking analysis was used to calculate 3D left ventricular longitudinal strain (LV-LS) in basal, mid and apical short-axis cine-images and to assess the presence of relative apical sparing. Receiver-operating-characteristic analysis revealed an area-under-the-curve regarding the differentiation of CA from HCM of 0.984 for native T1-mapping ( p   〈  0.001), of 0.985 for ECV ( p   〈  0.001) and only 0.740 for the “apical-to-(basal + midventricular)”-ratio of LV-LS ( p  = 0.012). A multivariable logistical regression analysis showed that ECV was the only statistically significant predictor of CA when compared to the parameter LV-LS or to the parameter “apical-to-(basal + midventricular)” LV-RLS-ratio. Native T1-mapping and ECV measurement are both superior to longitudinal strain measurement (with assessment of relative apical sparing) regarding the appropriate diagnosis of CA.
    Type of Medium: Online Resource
    ISSN: 2045-2322
    Language: English
    Publisher: Springer Science and Business Media LLC
    Publication Date: 2021
    detail.hit.zdb_id: 2615211-3
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...