Online Resource
Alwaha Scientific Publishing Services SARL
;
2022
In:
ASPS Conference Proceedings Vol. 1, No. 1 ( 2022-12-19), p. 467-471
In:
ASPS Conference Proceedings, Alwaha Scientific Publishing Services SARL, Vol. 1, No. 1 ( 2022-12-19), p. 467-471
Abstract:
Fire in a building is a casual phenomenon but cannot be completely ruled out in spite of the facts that buildings are provided with mandatory fire safety measures. A symmetrical in plan with 5 bays with 20 stories regular RCC building has been considered with fire at three different level that is at the bottom, middle and top. The building has been designed for gravity loads and lateral loads having three different configuration of shear walls and columns. Fire temperature of 700 0C was considered. The minimum value of maximum fire temperature for failure of vertical members has been found out by iterations. The worst verticals members due to fire has been identified and their displacement calculated. Best location of shear walls using commercial software etabs is used for the analysis and design.
Type of Medium:
Online Resource
ISSN:
2830-909X
Language:
English
Publisher:
Alwaha Scientific Publishing Services SARL
Publication Date:
2022
Permalink
|