GLORIA

GEOMAR Library Ocean Research Information Access

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    In: Transactions of the American Society of Civil Engineers, American Society of Civil Engineers (ASCE), Vol. 92, No. 1 ( 1928-01), p. 343-374
    Type of Medium: Online Resource
    ISSN: 0066-0604 , 2690-4071
    RVK:
    RVK:
    RVK:
    Language: English
    Publisher: American Society of Civil Engineers (ASCE)
    Publication Date: 1928
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 2
    Online Resource
    Online Resource
    SAGE Publications ; 2006
    In:  Proceedings of the Institution of Mechanical Engineers, Part D: Journal of Automobile Engineering Vol. 220, No. 1 ( 2006-01-01), p. 53-65
    In: Proceedings of the Institution of Mechanical Engineers, Part D: Journal of Automobile Engineering, SAGE Publications, Vol. 220, No. 1 ( 2006-01-01), p. 53-65
    Abstract: Car parking has been, and still is, a growing problem, with increasing vehicle sizes in the luxury segment as well as sport-utility vehicles. This is especially true when bearing in mind the confined parking spaces in parking lots and cities. While damage during parking generally does not cause any injury to the passengers, it is costly and annoying. Park assist systems are by no means new on the market, since passive systems which provide longitudinal guidance using ultrasonic distance sensors have been available on the market for a number of years. The system presented is a semi-automated approach to parallel parking problems, as they frequently occur in European and Asian cities. The challenge during the development of this system was to have as few components as possible added to a standard vehicle, seeking reuse of many of the already built-in functionalities. The result is a system that leaves the longitudinal control of the vehicle to the driver but automates the steering process, and even stops the vehicle when the final parking position is reached.
    Type of Medium: Online Resource
    ISSN: 0954-4070 , 2041-2991
    RVK:
    Language: English
    Publisher: SAGE Publications
    Publication Date: 2006
    detail.hit.zdb_id: 2032754-7
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 3
    Online Resource
    Online Resource
    SAGE Publications ; 2020
    In:  Lighting Research & Technology Vol. 52, No. 7 ( 2020-11), p. 856-882
    In: Lighting Research & Technology, SAGE Publications, Vol. 52, No. 7 ( 2020-11), p. 856-882
    Abstract: This study assesses the lighting requirements for operating theatres and the lighting conditions in a specific test case and proposes alternate ways of achieving a favourable visual environment. The hypothesis was that an increased illuminance level from general lighting and lower luminance contrasts between the essential task areas affect perceived lighting quality, visual ability and performance, as well as tiredness of medical staff performing surgical work. The investigation consisted of three parts: a laboratory study, followed by a field study and concluding with a retrospective study. In the laboratory study, each medical staff subject was exposed to four lighting scenarios with three illuminances from the operating light (12 lighting conditions), with no patients present. In the field and the retrospective study, the existing lighting scenario was compared to the highest-rated test lighting scenario (with illuminances more than double). The field study and the retrospective study took place with medical staff working under either the test general lighting condition or the existing general lighting condition. Increased illuminance from the general lighting and a higher correlated colour temperature did not improve the operating staff’s visual ability. However, medical staff rated the change in lighting quality resulting from the increased general illuminance as an improvement in the work environment, both in the laboratory study and in the field study. Medical staff subjects using the operating theatre rated both perceived visual ability and lighting quality higher under the test lighting scenario. Tiredness was also rated lower under that test scenario. Based on the results from this study, general lighting levels of 2000 lx in the periphery of the operating room, 4000 lx surrounding the operating table and 5500 lx on the operating table are recommended by the authors. With reference to the selections made by the surgeons for the illuminance in the operating cavity, it is suggested that the central beam illuminance from the surgical luminaires be between 50,000 lx and 100,000 lx.
    Type of Medium: Online Resource
    ISSN: 1477-1535 , 1477-0938
    RVK:
    Language: English
    Publisher: SAGE Publications
    Publication Date: 2020
    detail.hit.zdb_id: 2053874-1
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 4
    Online Resource
    Online Resource
    Wiley ; 2017
    In:  Materials and Corrosion Vol. 68, No. 2 ( 2017-02), p. 133-142
    In: Materials and Corrosion, Wiley, Vol. 68, No. 2 ( 2017-02), p. 133-142
    Abstract: Pure iron has been oxidized at 600 °C and 1 bar in dry O 2 (oxygen partial pressure 0.05, bal. N 2 ) and the mass gain as well as the thicknesses of the individual oxide phases have been measured. The oxidation process has been simulated using a modified version of the homogenization model as implemented in Dictra; this has helped to rationalize the kinetics of oxide scale formation and in particular the evolution of the hematite (Fe 2 O 3 ), magnetite (Fe 3 O 4 ), and wustite (FeO) which form. Independently assessed thermodynamic and kinetic Calphad databases are needed for the calculations; details of these are given. Reasonable agreement between simulation results and experimental data is obtained, though it is concluded that the large influence of grain boundary diffusion on the oxidation rate needs further consideration.
    Type of Medium: Online Resource
    ISSN: 0947-5117 , 1521-4176
    URL: Issue
    RVK:
    Language: English
    Publisher: Wiley
    Publication Date: 2017
    detail.hit.zdb_id: 1481051-7
    detail.hit.zdb_id: 1224916-6
    detail.hit.zdb_id: 202688-0
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
Close ⊗