A hydrogen-free DLC (diamond-like carbon) coating was deposited with a bias voltage of 150 V on various high and low alloy tool steels to study the effect of the pre-treatment of the steel substrate on the wear behaviour of the DLC coating in sliding contact with uncoated counterparts. The morphology and mechanical properties of the DLC coating as well as the effect of plasma nitriding on the surface roughness and the hardness of the steels were studied in order to perform a correlation with the results of tribology tests. It could be concluded from the results that the plasma nitriding of the high alloy tool steel X210CrW12 leads to a significant decrease in the wear and friction coefficient of the DLC coating. Furthermore, it was found that plasma nitriding of the steel results in a decrease in the wear of uncoated counterparts as well. Finally, the wear mechanisms and failure of DLC coatings deposited on various steels were compared with each other and discussed analytically.