GLORIA

GEOMAR Library Ocean Research Information Access

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Knee surgery, sports traumatology, arthroscopy 1 (1993), S. 44-50 
    ISSN: 1433-7347
    Keywords: Meniscus ; Meniscctomy ; Varus ; Biomechanics ; Knee
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine , Sports Science
    Notes: Abstract The purpose of this study was to determine the in vitro load-transmission characteristics of the canine knee, paying particular attention to the positioning effect of the meniscus in the coronal plane. The intact joint was first loaded and then tested under two different loading conditions after a complete medial meniscectomy. The first set of test conditions attempted to simulate those used by previous investigators, by ignoring the spacer effect of the meniscus. The second set of tests were carried ouf following varus rotation of the joint (to account for the loss of the meniscal spacer) to assure initial contact in both tibiofemoral compartments at the start of test cycle. It is presumed that this varus realignment occurs during weight bearing following meniscectomy in vivo. As in previous studies, the joints experienced slightly larger displacements (although not statistically significant) and had lower stiffness values following medial meniscectomy than when intact. However, following varus realignment of the joint after meniscectomy, the displacement was markedly smaller (−35% to −40%;P〈0.01) and the structural stiffness was much greater (47–123%;P〈0.05) over the range of forces analyzed, compared with the intact joint. The ratio of dissipated to input energy was 42% for the intact joint, and increased following meniscectomy to 54% (P〈0.05) with realignment and 55% (P〈0.05) without realignment. Measured contact area decreased by 17% (P〈0.05) following meniscectomy alone, and by 12% (P〈0.05) following meniscectomy with realignment. Scince varus rotation of the joint following meniscectomy resulted in an increase in structural stiffness, it was concluded that the medial meniscus reduces the structural stiffness of the intact joint. In addition, the meniscus has a role in elastic energy storage and increasing contact area. A model is presented to explain both the decrease in stiffness after meniscectomy without varus rotation and the increase in stiffness after meniscectomy with varus rotation, employing linear springs of unequal length and different stiffnesses. After removal of the softer meniscal element and allowing joint approximation to occur, loading of the stiffer articular element results in an initially stiffer preparation.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1573-4927
    Keywords: AHH ; SAH ; benzo[α]pyrene ; estradiol ; microsomal ; mixed-function oxygenase
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Chemistry and Pharmacology
    Notes: Abstract Aryl hydrocarbon hydroxylase and 16α-hydroxylase were examined in intact, cultured human lymphocytes. The two microsomal mixed-function oxygenases had different pH optima and showed competitive inhibition for enzyme induction and activity. Population distributions were lognormal for both enzymes, giving apparent evidence for polygenic control. Induced levels of AHH were slightly higher among first-order relatives of lung or colon cancer patients than in the control group. The correlation coefficient (r) for AHH and SAH co-inducibility was −0.08, indicating no correlation and suggesting the absence of association between the two enzymes in man.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    Biochemical genetics 13 (1975), S. 501-509 
    ISSN: 1573-4927
    Keywords: estrogen metabolism ; estradiol ; estriol ; hydroxylase
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Chemistry and Pharmacology
    Notes: Abstract Lymphocytes grown for 72 hr in the presence of mitogenic agents exhibited a nine-fold increase in 16α-hydroxylase activity over a 24-hr period following the addition of 17β-estradiol as an inducing agent. The major metabolite of 17β-estradiol produced by induced lymphocytes showed a chromatographic mobility indistinguishable from that of estriol. Enzymatic activity increased linearly with cell numbers, was inhibited by CO, and exhibited no induced increase in the presence of cycloheximide. A population survey indicated about 68% of a randomly selected Caucasian group to be essentially uninducible for 16α-hydroxylase.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 1573-2800
    Keywords: transsexual ; gonadotrophin ; estradiol ; feedback
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine , Psychology
    Notes: Abstract This project was an attempt to test Dörner's theory that aspects of gender identity and sexual behavior depend on a defect in a normal imprinting mechanism of testicular testosterone (T) on the male hypothalamus. It has been suggested that such an action by T is incomplete in male-to-female transsexuals and that in this disorder the hypothalamus retains a cyclic pattern of gonadotrophin secretion and a positive feedback response to estrogens, such as is seen in the normal female. Five untreated male-to-female transsexuals and five normal male controls were each given 2 mg IM of estradiol, and T, estradiol, LH, and FSH globulin was measured serially over the following five days. No significant differences were found in the gonadotrophin or any of the other hormone responses in the transsexuals compared to normal controls. If there is a defect in imprinting of the hypothalamus in transsexual men, it does not seem to affect the basal levels of gonadotrophins or the pattern of their response to estrogen, at least in the intact male.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Hoboken, NJ [u.a.] : Wiley-Blackwell
    Journal of Orthopaedic Research 7 (1989), S. 281-291 
    ISSN: 0736-0266
    Keywords: Meniscus ; Meniscectomy ; Canine ; Mechanics ; In vitro ; Life and Medical Sciences
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine
    Notes: The purpose of this study was to determine the in vitro load transmission characteristics of the canine stifle joint, paying particular attention to the positioning effect of the meniscus in the coronal plane. The intact joint was first loaded, and then tested under two different loading conditions after a complete medial meniscectomy. The first set of test conditions attempted to simulate those used by previous investigators, by ignoring the spacer effect of the meniscus and not repositioning the joint after its removal. The second set of tests was carried out after the joint was repositioned in the coronal plane to allow initial contact to occur in both tibiofemoral compartments. It is presumed that this occurs subsequent to a meniscectomy in vivo, following the application of any weight-bearing load. As with previous investigators, it was found that after meniscectomy the joints produced slightly larger displacements and lower stiffnesses than when intact (no significant differences from intact). However, repositioning the meniscectomized joint produced markedly smaller displacements (35-49%, p 〈 0.01) and greater stiffnesses (47-123%, p 〈 0.05) over the range of forces analyzed, compared with the intact joint. The ratio of dissipated to input energy was 42% for the intact joint, and rose following meniscectomy to 54% (p 〈 0.05) with repositioning and 55% (p 〈 0.05) without repositioning. Measured contact area decreased by 17% (p 〈 0.05) following meniscectomy alone, and by 12% (p 〈 0.05) following meniscectomy with repositioning. Since repositioning of the joint subsequent to meniscectomy (accounting for the loss of the meniscal spacer) resulted in an increse in structural stiffness, it was concluded that the medial meniscus decreases the structural stiffness of the intact stifle joint. In addition, the meniscus has a role in elastic energy storage and increasing contact area. This study is intended to serve as a baseline comparison for future in vivo studies on meniscetomy, meniscal repair, and meniscal replacement, in addition to more fully elucidating the mechanism of load transmission. A model is presented to explain both the decrease in stiffness after meniscectomy without repositioning and the increase in stiffness after meniscectomy with repositioning, employing linear springs of unequal length and different stiffnesses. After removal of the softer meniscal element and allowing joint approximation to occur, loading of the stiffer articular element results in an initially stiffer preparation.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...