Summary The carbon content was determined in the plasma of horizontal electric arc discharging between carbon electrodes in a) a graphite tube and b) a ceramic tube, in the presence of an inhomogeneous magnetic field. After 20 s of discharge, the carbon content reaches in the case a) a value of 8% and in the case b) a value of 3%. The compositions of the air plasma with 8% and 3% of carbon, respectively, in the temperature range of 500–6000 K were calculated according to the method described by White [8, 9] and the results obtained were compared with the experimental data. Carbon is present below 5000 K mainly in the form of CO and CO2.
Notes:
Zusammenfassung Der Kohlenstoffgehalt im Plasma einer horizontalen Bogenentladung zwischen Kohleelektroden im inhomogenen Magnetfeld wurde in einem Graphitrohr (a) und in einem Keramikrohr (b) gemessen. Nach 20 s Entladungsdauer erreichte der Kohlenstoffgehalt bei a) einen Wert von 8%, und bei b) von 3%. Die Zusammensetzung des Luftplasmas mit 8% bzw. 3% C wurde für den Temperaturbereich 500–6000 K nach White [8, 9] berechnet und mit den experimentellen Ergebnissen verglichen. Unter 5000 K liegt Kohlenstoff hauptsächlich als CO und CO2 vor.