GLORIA

GEOMAR Library Ocean Research Information Access

feed icon rss

Ihre E-Mail wurde erfolgreich gesendet. Bitte prüfen Sie Ihren Maileingang.

Leider ist ein Fehler beim E-Mail-Versand aufgetreten. Bitte versuchen Sie es erneut.

Vorgang fortführen?

Exportieren
Filter
  • Biochemistry and Biotechnology  (1)
  • Capillary contractility  (1)
  • Capillary diameter  (1)
Publikationsart
Schlagwörter
Verlag/Herausgeber
Erscheinungszeitraum
  • 1
    Digitale Medien
    Digitale Medien
    Springer
    Pflügers Archiv 382 (1979), S. 179-187 
    ISSN: 1432-2013
    Schlagwort(e): Tubular compliance ; Capillary diameter ; Tubular diameter ; Rat kidney
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Medizin
    Notizen: Abstract Tubular compliance is the response of tubular diameter to changes in intratubular pressure [7]. Proximal tubular compliance was determined directly by measurements of tubular diameter and pressure and indirectly using a mathematical model of tubular fluid flow based on measurements of the hydraulic pressure gradients along the tubule under free flow conditions and during an induced pressure reduction at the end of the proximal tubule. The two independent methods yielded similar values for compliance. Proximal tubular complicance was found to depend upon the intratubular pressure: tubular compliance was significantly higher (P〈0.001) when the intratubular pressure was reduced below normal (1.0 μm cm H2O−1) than when the pressure was increased above the control value (0.4 μm cm H2O−1) Almost identical compliance values were measured in sodium pentobarbital and inactin anaesthetized rats (P〉0.8). Intratubular pressure changes resulted in inverse changes in the diameters of the adjacent capillaries, suggesting that the peritubular capillaries are distensible structures.
    Materialart: Digitale Medien
    Standort Signatur Einschränkungen Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 2
    Digitale Medien
    Digitale Medien
    Springer
    Pflügers Archiv 371 (1977), S. 245-250 
    ISSN: 1432-2013
    Schlagwort(e): Angiotensin II ; Capillary contractility ; Rat kidney
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Medizin
    Notizen: Summary Large peritubular capillaries were infused consecutively (20 nl · min−1) in random sequence with isotonic saline and angiotensin II (20–80 ng · ml−1). The diameters of the infused capillaries were measured, without knowledge of the infusate used, from colour photographs of the infused area. Angiotensin II induced a significant (p〈0.001) decrease in capillary diameter (Δ=−1.2±0.2 (SE) μm and Δ=−2.1±0.2 (SE) μm with 20 ng · ml−1 and 80 ng · ml−1 angiotensin II infusates, respectively). This decrease was shown to be independent of external tubular compression: separate experiments in which the surrounding tubules were collapsed by injection of oil blocks yielded similar results. The possibility that the observed reduction in diameter was caused by an angiotensin II induced change in capillary permeability to the staining solution was excluded, since the angiotensin II effect was unchanged when fluorescent dextran (mol. wt. 150000) was substituted for lissamin green. These experiments indicate that peritubular capillaries contract actively when infused with angiotensin II.
    Materialart: Digitale Medien
    Standort Signatur Einschränkungen Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 3
    Digitale Medien
    Digitale Medien
    New York, NY [u.a.] : Wiley-Blackwell
    Biotechnology and Bioengineering 58 (1998), S. 191-195 
    ISSN: 0006-3592
    Schlagwort(e): control analysis ; Lactococcus lactis ; gene expression ; flux ; oligonucleotide ; Chemistry ; Biochemistry and Biotechnology
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Biologie , Werkstoffwissenschaften, Fertigungsverfahren, Fertigung
    Notizen: In this article, we review some of the expression systems that are available for Metabolic Control Analysis and Metabolic Engineering, and examine their advantages and disadvantages in different contexts. In a recent approach, artificial promoters for modulating gene expression in micro-organisms were constructed using synthetic degenerated oligonucleotides. From this work, a promoter library was obtained for Lactococcus lactis, containing numerous individual promoters and covering a wide range of promoter activities. Importantly, the range of promoter activities was covered in small steps of activity change. Promoter libraries generated by this approach allow for optimization of gene expression and for experimental control analysis in a wide range of biological systems by choosing from the promoter library promoters giving, e.g., 25%, 50%, 200%, and 400% of the normal expression level of the gene in question. If the relevant variable (e.g., the flux or yield) is then measured with each of these constructs, then one can calculate the control coefficient and determine the optimal expression level. One advantage of the method is that the construct which is found to have the optimal expression level is then, in principle, ready for use in the industrial fermentation process; another advantage is that the system can be used to optimize the expression of different enzymes within the same cell. © 1998 John Wiley & Sons, Inc. Biotechnol Bioeng 58:191-195, 1998.
    Zusätzliches Material: 3 Ill.
    Materialart: Digitale Medien
    Standort Signatur Einschränkungen Verfügbarkeit
    BibTip Andere fanden auch interessant ...
Schließen ⊗
Diese Webseite nutzt Cookies und das Analyse-Tool Matomo. Weitere Informationen finden Sie hier...