GLORIA

GEOMAR Library Ocean Research Information Access

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Arrhythmias, Catheter Ablation and Implantable Cardioverter-Defibrillator, Atrial Fibrillation, Pacemaker, Ischemic Stroke  (1)
Document type
Keywords
Years
  • 1
    Publication Date: 2016-10-19
    Description: Background: The RATE Registry (Registry of Atrial Tachycardia and Atrial Fibrillation Episodes) is a prospective, outcomes-oriented registry designed to document the prevalence of atrial tachycardia and/or fibrillation (AT/AF) of any duration in patients with pacemakers and implantable cardioverter defibrillators (ICDs) and evaluate associations between rigorously adjudicated AT/AF and predefined clinical events, including stroke. The appropriate clinical response to brief episodes of AT/AF remains unclear. Methods: Rigorously adjudicated electrogram (EGM) data were correlated with adjudicated clinical events with logistic regression and Cox models. Long episodes of AT/AF were defined as episodes in which the onset and/or offset of AT/AF was not present within a single EGM recording. Short episodes of AT/AF were defined as episodes in which both the onset and offset of AT/AF were present within a single EGM recording. Results: We enrolled 5379 patients with pacemakers (N=3141) or ICDs (N=2238) at 225 US sites (median follow-up 22.9 months). There were 359 deaths. There were 478 hospitalizations among 342 patients for clinical events. We adjudicated 37 531 EGMs; 50% of patients had at least one episode of AT/AF. Patients with clinical events were more likely than those without to have long AT/AF (31.9% vs. 22.1% for pacemaker patients and 28.7% vs. 20.2% for ICD patients; P 〈0.05 for both groups). Only short episodes of AT/AF were documented in 9% of pacemaker patients and 16% of ICD patients. Patients with clinical events were no more likely than those without to have short AT/AF (5.1% vs. 7.9% for pacemaker patients and 11.5% vs. 10.4% for ICD patients; P =0.21 and 0.66, respectively). Conclusions: In the RATE Registry, rigorously adjudicated short episodes of AT/AF, as defined, were not associated with increased risk of clinical events compared with patients without documented AT/AF. Clinical Trial Registration: URL: http://www.clinicaltrials.gov . Unique identifier: NCT00837798.
    Keywords: Arrhythmias, Catheter Ablation and Implantable Cardioverter-Defibrillator, Atrial Fibrillation, Pacemaker, Ischemic Stroke
    Electronic ISSN: 1524-4539
    Topics: Medicine
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...