GLORIA

GEOMAR Library Ocean Research Information Access

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Analytical Chemistry and Spectroscopy  (31)
  • Condensed Matter: Electronic Properties, etc.  (24)
  • Chemical Engineering  (22)
  • 1
    Electronic Resource
    Electronic Resource
    Chichester : Wiley-Blackwell
    Biological Mass Spectrometry 18 (1989), S. 321-327 
    ISSN: 0887-6134
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Increasingly widespread usage of stable isotope tracers to aid clinical diagnosis and support basic research has stemmed from both advances in mass spectrometry and the availability of competitively priced labelled compounds. Stable isotopes have been used generally to investigate normal and abnormal metabolic pathways, to estimate energy expenditure and body composition and to quantitate substrate flux and oxidation rates. Despite the fact that the underlying principles relating to the use of stable isotopes for in vivo studies are straightforward, careful consideration must be given to all aspects of human studies. This review highlights some of these, including choice of label and tracer molecule, mode of tracer administration and sampling site, analytical instrumentation, interpretation of data and ethical constraints.
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 3 (1980), S. 91-91 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, glass ; Static coating technique details ; End-sealing without failure, under ethanol ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 0935-6304
    Keywords: Gas chromatography, GC ; Fused silica capillary columns ; Electron capture detection ; Octachlorobenzo-p-dioxin ; Heptachlorobenzo-p-dioxin ; Polychlorinated dibenzofurans ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A method is described for the analysis of contaminated building dust samples and surface swab samples for octachlorodibenzo-p-dioxin (OCDD) and heptachlorodibenzo-p-dioxins (HpCDDs). The samples were analyzed by fused silica capillary GC combined with electron capture detection. Analysis was preceded by a short HPLC cleanup step designed to remove polychlorinated biphenyls (PCBs) and other compounds that might interfere. The method was found to work successfully on surface swab and dust samples known to contain PCBs, OCDD, and HpCDDs. The overall recovery of the analysis procedure for OCDD was found to be approximately 80%. The detection limit for the method was sample dependent, but for one typical set of surface swab samples was 0.2 μg/m2 of OCDD.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 2 (1979), S. 613-616 
    ISSN: 0935-6304
    Keywords: Gas chromatography, capillary, glass ; 5 mikrometer quartz powder roughening layer fused onto boro silicate glass during drawing process ; Complete procedure given reproducible preparation of stable thick film capillaries ; Static impregnation with 1.5% (w/v) rubber solutions possible ; Very low column bleed, ideal for GC-MS ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A detailed method for the routine preparation of glass capillary columns is presented. The method consists of coating a glass tube with quartz powder prior to pulling the tube into a capillary. The inner surface of the capillary consists of an even distribution of quartz particles fused to the walls. This surface has been found readily deactivated by standard procedures and ideal for the preparation of thick-film glass capillary columns. The method has been thoroughly tested in two independent laboratories to ensure that the procedures described are reproducible.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 5 (1982), S. 432-434 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Glass capillary columns ; Radiation induced polymerization ; Crosslinking ; Immobilized phases ; Column activity ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 13 (1990), S. 361-365 
    ISSN: 0935-6304
    Keywords: Capillary GC ; Electronic pressure control ; Pressure programming ; Constant flow ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Capillary gas chromatographic separations were performed with an electronic pressure control system developed to provide precise closed-loop control of inlet pressure through the use of a solid state micro-machined pressure sensor and electronically controlled proportional valve. The closed-loop control of the electronic system provided better precision than the open-loop control achieved by manual pressure regulation. Closed-loop control can perform pressure programming, which can be combined with temperature programming to optimize separations. The pressure sensor monitors the integrity of the flow system and singals the controller to reduce flow in the presence of a sudden loss of system pressure.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 16 (1993), S. 713-716 
    ISSN: 0935-6304
    Keywords: SFE ; Supercritical carbon dioxide ; Sand ; Test mixture ; Solvent trapping ; Solvent mixtures ; Trapping efficiency ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A polarity test mix consisting of acetophenone, N, N-dimethylaniline, naphthalene, decanoic acid, 2-naphthol, and n-tetracosane was spiked onto sand, and extracted with supercritical carbon dioxide, to evaluate the collection efficiency of various solvents and solvent mixtures. Nine single collection solvent systems and four mixed collection solvent systems were studied. When one-component collection solvents were employed, quantitative (above 90%) recovery of all analytes was not possible. With mixed collection solvents, recoveries of 90% or better with all analytes studied were possible.
    Additional Material: 4 Tab.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 17 (1994), S. 759-764 
    ISSN: 0935-6304
    Keywords: Supercrirtical fluid extraction (SFE) ; Modified carbon dioxide in SFE ; Liquid trapping ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A polarity test mix consisting of acetophenone, N,N-dimethylaniline, naphthalene, 2-naphthol, and n-tetracosane was spiked onto sand and extracted with carbon dioxide modified with acetonitrile, methanol, or toluene. The extracts were collected in chloroform, hexane, methanol, or a mixed collection solvent consisting of equal parts chloroform-hexane-methanol. The mixed collection solvent which showed excellent recoveries for pure CO2, had the worst recoveries of all the collection solvents with modified CO2. Overall hexane was the best collection solvent studied for these analytes under these extraction conditions.
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 14 (1991), S. 649-655 
    ISSN: 0935-6304
    Keywords: Capillary gas chromatography ; Splitless injection ; Electronic pressure programming ; Reduction in discrimination ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: An experimental injection port has been designed for split or splitless sample introduction in capillary gas chromatography; the inlet uses electronic pressure control, in order that the column head pressure may be set from the GC keyboard, and the inlet may be used in the constant flow or constant pressure modes. Alternatively, the column head pressure may be programmed up or down during a GC run in a manner analogous to even temperature programming. Using electronic pressure control, a method was developed which used high column head pressures (high column flow rates) at the time of injection, followed by rapid reduction of the pressure to that required for optimum GC separation. In this way, high flow rates could be used at the time of splitless injection to reduce sample discrimination, while lower flow rates could be used for the separation. Using this method, up to 5 μl of a test sample could be injected in the splitless mode with no discrimination; in another experiment, 2.3 times as much sample was introduced into the column by using electronic pressure programming. Some GC peak broadening was observed in the first experiment.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 15 (1992), S. 763-768 
    ISSN: 0935-6304
    Keywords: Capillary GC ; Splitless injection ; Electronic pressure programming ; (EPP) ; Endrin ; DDT ; Carbaryl ; Reducing sample decomposition ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A split/splitless capillary injection port has been developed for electronic pressure programming (EPP) in gas chromatography. The inlet may be operated in several modes: constant pressure, constant flow, vacuum compensation (for gas chromatography-mass spectrometry (GC-MS)), pressure-programmed, or a combination mode enabling a pressure program to be followed by constant flow. A pressure-programming technique has been tried which uses high pressure (high column flow rate) at the time of injection followed by reduction in inlet pressure to a value required for normal chromatography. Sample is swept rapidly from the inlet and into the column, reducing contact with the hot, active inlet surfaces which cause sample decomposition. The decomposition of endrin and 4,4′-DDT, two labile pesticides, can be substantially reduced using this technique and modest improvements were also observed with the carbamate pesticide carbaryl.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...