    ISSN: 0887-6134
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A method has been developed for the quantitative determination of cholesterol and three of its major oxidative metabolites (the 5α,6α-epoxide, the 3β,5α,6β-triol, and the 5β,6β-epoxide) in a single sample of human breast fluid (2-50 μl), using gas chromatography/mass spectrometry with selected ion monitoring. High specificity and reliable quantification is achieved by the use of the inverse stable isotope dilution method, employing deuterium-labeled variants of the compounds as internal standards.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Stamford, Conn. [u.a.] : Wiley-Blackwell
    Polymer Engineering and Science 32 (1992), S. 426-430 
    ISSN: 0032-3888
    Keywords: Chemistry ; Chemical Engineering
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Notes: A foam rheometer has been developed based on the impulse theory of linear viscoelasticity. The rheometer is a large-volume parallel-plate device which operates under gap-loaded conditions, and is designed as an add-on fixture for the Materials Testing System Model 312. The rheometer provides characterization data of the pre-gel (via the zero-shear viscosity) or the post-gel (via the equilibrium modulus) properties of a foaming cellular polymer with a precision of better than ± 15%.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Stamford, Conn. [u.a.] : Wiley-Blackwell
    Polymer Engineering and Science 33 (1993), S. 317-321 
    ISSN: 0032-3888
    Keywords: Chemistry ; Chemical Engineering
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Notes: Sample size sensitivity of thermal gravimetric analysis (TGA) presents a serious handicap in the obtaining of reliable thermal stability data for high-temperature applications. For example, predictions of the apparent time for degradation during an isothermal experiment based on the results obtained using a 10 μm thick specimen can be off by an order of magnitude when applied to a product with a thickness of 10 cm. To address this effect, TGA experiments studying the thermal degradation of poly(methyl methacrylate) were conducted. Analysis of the experimental data resulted in the development of a relationship between the apparent time scale of the thermal degradation and the specimen thickness. Origins of the new dependence were traced to the change of the diffusivity resulting from material volatilization. Implications of the coupling between these two events for the analysis of thermal stability for new polymeric materials are discussed, and required changes in the current methodology are outlined.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Chichester : Wiley-Blackwell
    Biological Mass Spectrometry 7 (1980), S. 381-384 
    ISSN: 1052-9306
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: An improved analog four-channel selected ion recording system is described, in which major modifications permit a decrease in the dwell time to 33 ms per channel, thus minimizing the mass cycling error. Synchronization with a sinusoidal sweep voltage superimposed on the normal accelerating voltage (8 kV) enables two channels to be monitored simultaneously in real time and each mass to be recorded continuously. These improvements allow measurement of ion current ratios with a precision of 0.2% over a wide dynamic range, permitting accurate determination of isotopic enrichment in biomedical assays even when this enrichment is derived from a single label. Use of the system is illustrated by the analysis of palmitate turnover in dogs (using [1 - 13C] palmitic acid) with an average standard deviation corresponding to the detection of 0.04% excess of [1 - 13C] palmitate.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Chichester : Wiley-Blackwell
    Biological Mass Spectrometry 1 (1974), S. 418-422 
    ISSN: 1052-9306
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: An analog multiple ion detection system has been developed for magnetic sector mass spectrometers based on accelerating voltage alternation in conjunction with the accurate maintenance of focusing by means of voltage sweeping, using a superimposed a.c. sine wave voltage. This multiple ion detector voltage sweep system is easily constructed, inexpensive and produces analytical data of much greater precision than that reported from conventional systems. The application of the multiple ion detector voltage sweep system to biomedical problems is illustrated by the development of a method for the determination of stable isotope enrichment in blood glucose and alanine in children infused with tetradeuterio-L-alanine and dideuterioglucose to study gluconeogenesis and glucose utilization in vivo.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 6
    ISSN: 1052-9306
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A method for the quantitative determination of chlorpromazine and five of its major metabolites in a single sample of biological fluid in the ng/ml range has been developed utilizing gas chromatography/mass spectrometry with selected ion recording. The assay is highly specific and quantification is accomplished by an inverse stable isotope dilution technique, using deuterium-labeled variants of the compounds as internal standards. In this way the concentrations of chlorpromazine and five of its major metabolites (the sulfoxide, the N-oxide, the monodemethylated, the didemethylated, and the 7-hydroxylated compounds) can be determined in biological fluids. Levels in humans have been measured both in plasma and in red blood cells and are compared to those found in related in vitro studies.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 7
    ISSN: 0002-9106
    Keywords: Life and Medical Sciences ; Cell & Developmental Biology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine
    Notes: Tissue obtained from young dogs was fixed in buffered aldehydes by vascular perfusion or direct immersion. Selected hearts were maintained in modified mammalian Ringer's solution for three to five minutes prior to fixation. The chambers of the heart and related valves were exposed by dissection and prepared by routine techniques for observation by scanning electron microscopy (SEM). Subsequent to SEM studies, selected specimens were embedded in Epon 812 and sectioned for transmission electron microscopy (TEM).The cardiac endothelium, when fixed immediately in buffered aldehydes, presents an essentially invariable surface throughout the interior of the heart. The predominant nuclear bulges and attenuated peripheral plasmalemma are consistently smooth, with occasional marginal ruffles, scattered microvilli and small blebs. Apart from the higher population of nuclear bulges on valvular surfaces, local variations in SEM of endocardium occur in response to the various stages of systole and diastole encountered. These physiological changes do not produce microappendages.Immersion for three to five minutes in (Chenoweth's) Ringer's solution, prior to fixation, produces a substantial population of microappendages. The cellular surface acquires a swirled appearance erupting in microvilli, blebs and ruffles. These exhibit considerable pleomorphism.There is great lability of the endocardial surface in response to a classic “holding solution” widely used in preparatory techniques. In preparing soft tissues for SEM caution must be used if physiological “holding solutions” are used prior to fixation.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Chichester : Wiley-Blackwell
    Biological Mass Spectrometry 10 (1983), S. 458-462 
    ISSN: 0306-042X
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A stable isotope tracer method has been developed for studying lactate metabolism in humans. The method uses lactic acid triply labeled with 13C as the tracer. The stable isotope is infused to attain a level of approximately 1.5% of that of the circulating unlabeled lactate. Following the isolation of lactic acid from the blood, the percentage of triply labeled (13C)lactate is measured using gas chromatography mass spectrometry. We compared this method with tracer methodology using [14C]lactate and found comparable results.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Bioelectromagnetics 17 (1996), S. 131-137 
    ISSN: 0197-8462
    Keywords: statistical power ; duration discrimination ; blood pressure ; heart rate ; Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Notes: One hundred subjects, males and females with ages ranging between 18 and 48 years, were studied under both field-exposed and sham-exposed conditions. A 50 Hz, 100 μT magnetic field (MF) was used. To examine the effect of field exposure on performance, a two-alternative, forced-choice, duration-discrimination task with three levels of difficulty was used. The subject's task was to decide which of two sequentially presented light flashes had the longer duration. The standard duration was 50 ms, and the alternative durations were 65, 100, or 125 ms. Both reaction time and percentage of correct responses were recorded for each subject. MF and sham exposure were for 9 min each. Blood pressure and heart rate were also measured before and following MF exposure and sham-exposure trials. The study was performed double blind, with the exposure order counterbalanced. Compared to sham exposure, MF exposure significantly decreased reaction time on the hardest level of the performance task. MF exposure did not reliably affect percentage correct or cardiovascular performance. It was demonstrated that a relatively high level of statistical power was the basis for the observed MF effect, and the need to pay closer attention to power levels in future research is discussed. © 1996 Wiley-Liss, Inc.
    Additional Material: 2 Tab.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 10
    ISSN: 0749-1581
    Keywords: Cobalt(III) porphyrins ; Conformations ; Azacyclooctane ; Azacycloheptane ; NMR ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A novel NMR shift reagent, cobalt(III) meso-tetraphenylporphyrin (CoTPP) was used to determine the conformations of azacycloheptane and azacyclooctane ligands complexed to the metalloporphyrin. Using the observed ring current shifts and a previously calibrated ring current model, the best agreement between the observed and calculated ring current shifts for azacycloheptane was obtained for a chair conformation, in agreement with previous theoretical and experimental studies on the conformational stability of seven-membered rings. The ring current shifts for azacyclooctane are best interpreted in terms of a mixture of many conformations. These results suggest that CoTPP may be useful as a probe of other conformationally mobile ligands.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...