GLORIA

GEOMAR Library Ocean Research Information Access

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 0173-0835
    Keywords: 2-D PAGE ; Reproducibility ; Immobilized pH gradient ; Yeast ; Chemistry ; Biochemistry and Biotechnology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Chemistry and Pharmacology
    Notes: An interlaboratory comparison was conducted on the positional and quantitative reproducibility of yeast proteins resolved by two-dimensional polyacrylamide gel electrophoresis (2-D PAGE) using isoelectric focusing with immobilized pH gradient (pH 4-7) in the first dimension. The basic experimental set-up was as follows: one laboratory prepared and distributed a [35S]methioninelabeled total yeast protein extract (Göteborg, Sweden), another laboratory prepared the IPG strips to be used by all labs in this study (Munich, Germany), the third laboratory (Aarhus, Denmark) circulated the protocols and coordinated the modest attempts to unify them. Samples were run horizontally in the first dimension and vertically in the second. The gels were sent to Göteborg for processing by phosphoimager technology and computerized image analysis (PDQuest), and the 2-D PAGE resolved proteins were located and quantified automatically. A subset of 470 spots was manually matched in all gels out of an average of 1328 resolved proteins. The positional interlaboratory comparison revealed great pattern reproducibility, the correlation coefficient in no case being less than 0.9994. In absolute terms an average deviation of 2.8 mm (x-position) and 1.8 mm (y-position) were obtained for all nine gels (three gels per lab). The interlaboratory comparison of protein quantitation displayed higher variability, and the best correlation coefficient generated was 0.975. An average standard deviation of 34.5% was calculated for protein quantitation including all three labs, a value slightly higher than the intralaboratory variation (range 20-28%) Thus, despite differences in protocols, chemicals and equipment, the immobilized pH gradient technology gave extremely high positional and quantitative reproducibility. This will greatly facilitate the exchange of data and the establishment of multi-user image-based 2-D gel databases.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...