GLORIA

GEOMAR Library Ocean Research Information Access

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Chemistry/Pharmacy  (2)
  • VA 2367  (2)
Material
Publisher
Language
Years
Subjects(RVK)
  • Chemistry/Pharmacy  (2)
RVK
  • VA 2367  (2)
  • 1
    In: Applied Spectroscopy, SAGE Publications, Vol. 77, No. 4 ( 2023-04), p. 371-381
    Abstract: A simple cost-effective laser-induced breakdown spectroscopy (LIBS) instrument was used for quantification of major elements in several nickel alloys and also sorting them. A compact low-power diode-pumped solid-state laser and a miniature low-resolution spectrometer were assembled for the LIBS instrument. Material properties of the nickel alloys depend mainly on the composition of the major elements, Ni, Cr, and Fe, ranging from a few to ∼60 wt%. The emission peaks at 547.7 nm, 520.4 nm, and 438.1 nm for Ni, Cr, and Fe, respectively, were chosen for this analysis. The analytical performance was found to be enough for the quantification of Ni, Cr, and Fe in the nickel alloys. Limits of detection and accuracy were estimated to be a few weight percent (wt%) and measurement precisions were less than 10% in terms of relative standard deviation. The calibration performance of this intensity-based method was compared with that of the “ratio method” which is used in conventional optical emission spectroscopy analyses. The comparison indicates that the intensity-based method is more appropriate with the low-performance LIBS instrument that detects emission peaks of only a few major elements. Also, multivariate modeling of the six different nickel alloy samples based on the emission peak intensities of Ni, Cr, and Fe was performed using k-nearest neighbors (KNN) and linear discriminant analysis (LDA). The KNN and ordinary LDA models showed 95.0% and 98.3% classification correctness for the separate test data set, respectively. To improve classification performance further, the two-step LDA model was trained. In this approach, the two closest sample classes responsible for the decrease in the classification correctness were separately modeled in the second step to exploit their difference effectively. The two-step LDA model showed 100% correctness in classifying the test objects. Our results indicate that such a low-performance LIBS instrument can be effectively utilized for quantitative analysis of the major elements in the nickel alloys and their rapid identification or sorting in combination with an appropriate multivariate modeling algorithm.
    Type of Medium: Online Resource
    ISSN: 0003-7028 , 1943-3530
    RVK:
    Language: English
    Publisher: SAGE Publications
    Publication Date: 2023
    detail.hit.zdb_id: 1474251-2
    SSG: 11
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 2
    In: Applied Spectroscopy, SAGE Publications, Vol. 73, No. 10 ( 2019-10), p. 1172-1182
    Abstract: Feasibility of a simple laser-induced breakdown spectroscopy (LIBS) device has been investigated for the analysis of Mg and Ca in edible salts. The LIBS spectrometer was assembled with a compact low-power diode-pumped solid-state laser (DPSSL) and a non-gated low-resolution handheld spectrometer. A simple sampling process was employed for on-site application. A piece of filter paper was dipped in the aqueous solution of a sample salt and dried for analysis using LIBS. Maintaining the sample surface height at the optimum position was critical to generate plasmas persistently due to the low pulse energy of the DPSSL. The varying height of the filter paper surface was monitored and compensated, while the sample stage was translated to collect spectra from different positions. The variation of line intensities of Mg and Ca could be attributed to the inhomogeneous distribution of dry residues. To correct this, the peak that consists of the Na(I) and C(II) lines at 568 nm was employed as a reference signal for intensity normalization of the analyte Mg(II) and Ca(II) lines. For edible salt products, the normalized Mg(II) and Ca(II) line intensities could be well correlated with the concentrations of Mg and Ca determined using inductively coupled plasma optical emission spectroscopy. Our results indicate that a simple LIBS device in combination with the simple sampling method is promising as an on-site salt quality assessment methodology.
    Type of Medium: Online Resource
    ISSN: 0003-7028 , 1943-3530
    RVK:
    Language: English
    Publisher: SAGE Publications
    Publication Date: 2019
    detail.hit.zdb_id: 1474251-2
    SSG: 11
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...