GLORIA

GEOMAR Library Ocean Research Information Access

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    In: Journal of the American Geriatrics Society, Wiley, Vol. 69, No. 2 ( 2021-02), p. 494-499
    Abstract: Transcatheter aortic valve implantation (TAVI) is a minimally invasive, life‐saving treatment for patients with severe aortic valve stenosis that improves quality of life. We examined cardiac output and cerebral blood flow in patients undergoing TAVI to test the hypothesis that improved cardiac output after TAVI is associated with an increase in cerebral blood flow. DESIGN Prospective cohort study. SETTING European high‐volume tertiary multidisciplinary cardiac care. PARTICIPANTS Thirty‐one patients (78.3 ± 4.6 years; 61% female) with severe symptomatic aortic valve stenosis. MEASUREMENTS Noninvasive prospective assessment of cardiac output (L/min) by inert gas rebreathing and cerebral blood flow of the total gray matter (mL/100 g per min) using arterial spin labeling magnetic resonance imaging in resting state less than 24 hours before TAVI and at 3‐month follow‐up. Cerebral blood flow change was defined as the difference relative to baseline. RESULTS On average, cardiac output in patients with severe aortic valve stenosis increased from 4.0 ± 1.1 to 5.4 ± 2.4 L/min after TAVI ( P = .003). The increase in cerebral blood flow after TAVI strongly varied between patients (7% ± 24%; P = .41) and related to the increase in cardiac output, with an 8.2% (standard error = 2.3%; P = .003) increase in cerebral blood flow per every additional liter of cardiac output following the TAVI procedure. CONCLUSION Following TAVI, there was an association of increase in cardiac output with increase in cerebral blood flow. These findings encourage future larger studies to determine the influence of TAVI on cerebral blood flow and cognitive function.
    Type of Medium: Online Resource
    ISSN: 0002-8614 , 1532-5415
    URL: Issue
    Language: English
    Publisher: Wiley
    Publication Date: 2021
    detail.hit.zdb_id: 2040494-3
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 2
    In: Journal of Neuroimaging, Wiley, Vol. 28, No. 5 ( 2018-09), p. 524-529
    Abstract: Imaging may identify patients with very large infarcts who are unlikely to benefit from intra‐arterial therapy. Although computed tomography (CT) is widely used, it suffers from poor sensitivity. We sought to evaluate whether combined evaluation of noncontrast CT (NCCT) and CT angiography (CTA) collaterals would improve the detection of large infarcts. METHODS All patients with anterior circulation proximal artery occlusion and baseline CT, CTA, and magnetic resonance imaging (MRI) performed were identified. NCCT ASPECTS, CTA collateral score (CS), and diffusion‐weighted imaging (DWI) lesion volume were determined. Receiver‐operating characteristic analyses were performed to test the discrimination of NCCT ASPECTS 0‐4, CTA malignant collaterals (CS = 0: absent collaterals in 〉 50% of M2 territory), and the combination for DWI volume 〉 100 mL. RESULTS Among 54 patients, mean age was 67 years; median NIHSS was 14. Occlusion locations were ICA terminus (18 [33%]), MCA M1 (20 [37%] ), and M2 (16 [30%]). Median NCCT ASPECTS was 8; 8 (15%) had ASPECTS 0‐4. Median CTA CS was 2; 9 (17%) were categorized as malignant. Median DWI lesion volume was 25 mL; 12 (22%) had lesions 〉 100 mL. Individually, the CTA malignant collateral profile (98%) and NCCT ASPECTS 0‐4 (100%) demonstrated high specificity for DWI lesion volume 〉 100 mL, but had suboptimal sensitivity (both 67%). In the combined approach (CTA CS = 0 and/or NCCT ASPECTS ≤4), the sensitivity improved significantly to 92%, while maintaining high specificity (98%). CONCLUSIONS Combined evaluation of NCCT ASPECTS and CTA collaterals identifies patients with infarcts 〉 100 mL with high accuracy, and can improve patient selection using current CT techniques.
    Type of Medium: Online Resource
    ISSN: 1051-2284 , 1552-6569
    URL: Issue
    Language: English
    Publisher: Wiley
    Publication Date: 2018
    detail.hit.zdb_id: 2035400-9
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...