GLORIA

GEOMAR Library Ocean Research Information Access

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Wiley  (1)
  • 1
    In: Experimental Physiology, Wiley, Vol. 106, No. 2 ( 2021-02), p. 532-543
    Abstract: What is the central question of this study? The study aimed to establish a novel model to study the chronic obstructive pulmonary disease (COPD)‐related cardiopulmonary effects of dynamic hyperinflation in healthy subjects. What is the main finding and its importance? A model of expiratory resistance breathing (ERB) was established in which dynamic hyperinflation was induced in healthy subjects, expressed both by lung volumes and intrathoracic pressures. ERB outperformed existing methods and represents an efficacious model to study cardiopulmonary mechanics of dynamic hyperinflation without potentially confounding factors as present in COPD. Abstract Dynamic hyperinflation (DH) determines symptoms and prognosis of chronic obstructive pulmonary disease (COPD). The induction of DH is used to study cardiopulmonary mechanics in healthy subjects without COPD‐related confounders like inflammation, hypoxic vasoconstriction and rarefication of pulmonary vasculature. Metronome‐paced tachypnoea (MPT) has proven effective in inducing DH in healthy subjects, but does not account for airflow limitation. We aimed to establish a novel model incorporating airflow limitation by combining tachypnoea with an expiratory airway stenosis. We investigated this expiratory resistance breathing (ERB) model in 14 healthy subjects using different stenosis diameters to assess a dose–response relationship. Via cross‐over design, we compared ERB to MPT in a random sequence. DH was quantified by inspiratory capacity (IC, litres) and intrinsic positive end‐expiratory pressure (PEEPi, cmH 2 O). ERB induced a stepwise decreasing IC (means (95% CI): tidal breathing: 3.66 (3.45–3.88), ERB 3 mm: 3.33 (1.75–4.91), 2 mm: 2.05 (0.76–3.34), 1.5 mm: 0.73 (0.12–1.58) litres) and increasing PEEPi (tidal breathing: 0.70 (0.50–0.80), ERB 3 mm: 11.1 (7.0–15.2), 2 mm: 22.3 (17.1–27.6), 1.5 mm: 33.4 (3.40–63) cmH 2 O). All three MPT patterns increased PEEPi, but to a far lesser extent than ERB. No adverse events during ERB were noted. In conclusion, ERB was proven to be a safe and efficacious model for the induction of DH and might be used for the investigation of cardiopulmonary interaction in healthy subjects.
    Type of Medium: Online Resource
    ISSN: 0958-0670 , 1469-445X
    URL: Issue
    Language: English
    Publisher: Wiley
    Publication Date: 2021
    detail.hit.zdb_id: 1493802-9
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...