  • 1
    In: Cancer Medicine, Wiley, Vol. 9, No. 10 ( 2020-05), p. 3261-3267
    Abstract: To assess the incidence of benign and malignant peri‐implant fluid collections and/or masses on magnetic resonance imaging (MRI) in women with silicone implants who are being screened for silent implant rupture. Methods The institutional review board approved this HIPAA‐compliant retrospective study and waived informed consent. Women who underwent silicone implant oncoplastic and/or cosmetic surgery and postoperative implant‐protocol MRI from 2000 to 2014 were included. Peri‐implant fluid collections and/or masses were measured volumetrically. A benign peri‐implant fluid collection and/or mass was pathologically proven or defined as showing 2 years of imaging and/or clinical stability. A malignant peri‐implant fluid collection was pathologically proven. Incidence of peri‐implant fluid collections and/or masses and positive predictive value (PPV) were calculated on a per‐patient level using proportions and exact 95% confidence intervals (CIs). Fisher's exact test was used in the analysis to test statistical significance pre‐defined as P ‐value  〈  0.05. Results A total of 1070 women with silicone implants were included (mean age, 50.7 years; range, 40.4‐53.8). Median time between reconstructive surgery and first MRI was 88.9 months (range, 0.8‐1363.3). Eighteen women (1.7%) had a peri‐implant fluid collection and/or mass: 15/18 (83.3%) had adequate follow‐up; and only 1/15 was malignant implant associated anaplastic large cell lymphoma, with a PPV of 6.7% (95% CI: 0.003‐0.0005). The median peri‐implant fluid collection size was 89 mL (range, 18‐450 mL). Conclusion Peri‐implant fluid collections and/or masses identified at silicone implant protocol breast MR imaging are rarely seen 24 months after reconstructive surgery. Image‐guided fine‐needle aspiration with flow cytometry may be warranted to evaluate for implant‐associated lymphoma.
    Type of Medium: Online Resource
    ISSN: 2045-7634 , 2045-7634
    URL: Issue
    Language: English
    Publisher: Wiley
    Publication Date: 2020
    detail.hit.zdb_id: 2659751-2
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...