In:
Advanced Materials Research, Trans Tech Publications, Ltd., Vol. 194-196 ( 2011-2), p. 275-282
Abstract:
In this paper, Potentiodynamic scans and Potentiostatic experiments are used to study manganese electro deposition on stainless steel and titanium substrates from simple chloride solutions with addition of ammonium chloride. The surface morphology and the crystal structure of manganese electrodeposits are analyzed by scanning electron microscope (SEM) and powder X-ray diffraction spectrometer (XRD), respectively. The comparison of electrolysis manganese craft on stainless steel and titanium, It is found that precipitation hydrogen is easier and the cell voltage is higher on stainless steel ,but there are more side reactions on titanium; The cubic crystal form manganese deposite on stainless steel and titanium, but the higher pure degree manganese can be obtained on stainless steel, the depositions on the titanium are imply impurity.
Type of Medium:
Online Resource
ISSN:
1662-8985
DOI:
10.4028/www.scientific.net/AMR.194-196
DOI:
10.4028/www.scientific.net/AMR.194-196.275
Language:
Unknown
Publisher:
Trans Tech Publications, Ltd.
Publication Date:
2011
detail.hit.zdb_id:
2265002-7
Permalink