In:
Applied Mechanics and Materials, Trans Tech Publications, Ltd., Vol. 587-589 ( 2014-7), p. 602-605
Abstract:
This paper reports a design proposal of a sonochemical setup for pesticide wastewater degradation. Multi-parameters obtained by multi-sensors of the setup were utilized to control experimental variables and analyze degradation effect. Based on the setup and method designed, degradation experiments of deltamethrin were set up. In the work, treatments using ultrasonic, ozone, and the combination of them were carried out respectively, and parameters including ultrasonic frequency, pH, electrical conductivity, temperature as well as mass were taken into consideration. Results indicated that deltamethrin could be degraded efficiently under the irradiation of 589 kHz US/O 3 combined and the degradation rate could reach 91%.
Type of Medium:
Online Resource
ISSN:
1662-7482
DOI:
10.4028/www.scientific.net/AMM.587-589
DOI:
10.4028/www.scientific.net/AMM.587-589.602