GLORIA

GEOMAR Library Ocean Research Information Access

Ihre E-Mail wurde erfolgreich gesendet. Bitte prüfen Sie Ihren Maileingang.

Leider ist ein Fehler beim E-Mail-Versand aufgetreten. Bitte versuchen Sie es erneut.

Vorgang fortführen?

Exportieren
Filter
  • The Angle Orthodontist (EH Angle Education & Research Foundation)  (1)
Materialart
Verlag/Herausgeber
  • The Angle Orthodontist (EH Angle Education & Research Foundation)  (1)
Sprache
Erscheinungszeitraum
Fachgebiete(RVK)
  • 1
    Online-Ressource
    Online-Ressource
    The Angle Orthodontist (EH Angle Education & Research Foundation) ; 2016
    In:  The Angle Orthodontist Vol. 86, No. 6 ( 2016-11-01), p. 883-890
    In: The Angle Orthodontist, The Angle Orthodontist (EH Angle Education & Research Foundation), Vol. 86, No. 6 ( 2016-11-01), p. 883-890
    Kurzfassung: Objective: To evaluate whether overloading of teeth can be avoided by utilizing aligners with reduced thicknesses of 0.4 mm or 0.3 mm. Materials and Methods: The experimental setup included an acrylic maxillary jaw model with tooth 11 separated and fixed via a 3-D force-moment transducer to a hexapod for experimental movement. Aligners tested were fabricated on duplicate stone models using commercially available polyethylene terephthalate glycol (PET-G) foils with thicknesses between 0.5 and 0.75 mm, and novel 0.4-mm- and 0.3-mm-thick foils. With the test aligner seated, 11 was bodily displaced in a labiopalatal direction in the range of ±0.25 mm while all six force-and-moment components exerted on this tooth were registered. Results: With the thinnest commercially available 0.5-mm aligner, median forces of −7.89 N and 8.37 N were measured for the maximum 0.25-mm movement of 11 in a labial and palatal direction, respectively. In comparison, force values were 35% and 71% lower for the novel aligners with a thickness of 0.4 mm and 0.3 mm, respectively. Conclusions: Novel “leveling” aligners with reduced thickness may reduce overloading of individual teeth during aligner therapy. Due to form instability of 0.3-mm aligners, we suggest a novel sequence of 0.4–0.5–0.75 mm for aligner systems using several foil thicknesses for load graduation within single setup steps. This would combine low stiffness of the initial aligner and relatively constant load increases throughout the treatment.
    Materialart: Online-Ressource
    ISSN: 0003-3219 , 1945-7103
    RVK:
    Sprache: Englisch
    Verlag: The Angle Orthodontist (EH Angle Education & Research Foundation)
    Publikationsdatum: 2016
    ZDB Id: 2026352-1
    Standort Signatur Einschränkungen Verfügbarkeit
    BibTip Andere fanden auch interessant ...
Schließen ⊗
Diese Webseite nutzt Cookies und das Analyse-Tool Matomo. Weitere Informationen finden Sie hier...