    Keywords: Coronary stenosis ; Micrometer constrictor ; Coronarstenose ; Mikrometer-Coronardrossel
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Zusammenfassung Bei Coronarstenosen ist die Verminderung der Lumenquerschnittsfläche die hämodynamisch entscheidende Größe. Bei experimenteller Coronarstenosierung werden jedoch im allgemeinen nur Angaben zur Verringerung des Coronardurchmessers gemacht. Mit einer exzentrisch einengenden Coronardrossel wurde das Verhältnis von Durchmesser-/Querschnittsflächenreduktion (D/Q) bei vier unterschiedlichen Silikonkautschukschläuchen untersucht, deren Größen anhand von Coronarausgußpräparaten von Schäferhunden ausgewählt wurden. In den Untersuchungen ergab sich eine lineare D/Q-Relation, die durch die Wandstärken von 0,3–0,4 mm wenig beeinflußt wurde. Eine Lumenquerschnittsflächenreduktion, die mit der Einengung des Coronardurchmessers identisch war, ließ sich nur erzielen, wenn der Durchmesser der Coronardrossel dem Gefäßdurchmesser angepaßt war.
    Notes: Summary The hemodynamic relevance of a coronary stenosis depends essentially upon the reduction of the cros-sectional area of the coronary lumen. However, the extent of experimental coronary narrowing is measured generally by determining the coronary diameter. In a series of experiments, the relationship between diameter and cross-sectional area (d/a) was determined using a micrometer constrictor and four different silastic tubings the size of which reflected actual coronary diameters as measured in coronary casts of German shepherd dogs. The d/a relationship was linear over a range of diameter reductions from 50 to 90%. A “physiologic” wall thickness of 0.3–0.4 mm had no major influence on the d/a relationship. However, identical reductions of diameters and cross-sectional areas could only be achieved with the tubing fitting exactly into the curvature of the coronary constrictor.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...