GLORIA

GEOMAR Library Ocean Research Information Access

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • SLACK, Inc.  (2)
Material
Publisher
  • SLACK, Inc.  (2)
Language
Years
  • 1
    Online Resource
    Online Resource
    SLACK, Inc. ; 1994
    In:  Ophthalmic Surgery, Lasers and Imaging Retina Vol. 25, No. 3 ( 1994-03), p. 180-185
    In: Ophthalmic Surgery, Lasers and Imaging Retina, SLACK, Inc., Vol. 25, No. 3 ( 1994-03), p. 180-185
    Abstract: ABSTRACT In cooperation with Morcher GmbH, we developed a black-diaphragm aphakia intraocular lens (IOL) designed to correct congenital and traumatic aniridia. Since June 1991, we have implanted this IOL into five eyes with congenital aniridia combined with cataract, and into eight eyes with traumatic aniridia combined with cataract or aphakia. Positioning the IOL was rather difficult, especially in the traumatic cases with inadequate capsular support, and in combination with penetrating keratoplasty. After up to 15 months' follow up, functional results are encouraging. However, slight persistent intraocular inflammation was observed in all of the eyes, more obviously in the traumatic cases. The effect of the IOL on the corneal endothelium is still being investigated. Cystoid macular edema was observed in one eye, but probably preexisted in this eye, following several earlier surgical procedures. Glaucoma was observed preoperatively in five eyes; postoperatively, in six. After surgery, it was controlled medically in 4 eyes, surgically in 1, and remained uncontrolled in 1.
    Type of Medium: Online Resource
    ISSN: 2325-8160 , 2325-8179
    Language: English
    Publisher: SLACK, Inc.
    Publication Date: 1994
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 2
    In: Journal of Refractive Surgery, SLACK, Inc., Vol. 9, No. 5 ( 1993-09), p. 333-339
    Abstract: RÉSULTATS: En utilisant nos techniques, l'aiguille pénétrait les protubérances ciliaires dans la plupart des cas. Les meilleurs résultats furent obtenus en passant l'aiguille de l'extérieur à l'intérieur avant d'ouvrir l'oeil. Chez l'oeil déjà hypotonique, les protubérances ciliaires tendaient à descendre devant l'aiguille, ce qui entraînait la fixation de la lentille dans le pars plicata. Dans la greffe transfixiante, le passage de l'aiguille de l'intérieur vers l'extérieur en avançant la pointe à tâtons marchait bien. Néanmoins, la bonne pénétration de l'aiguille dans le sulcus ciliaire ne garantissair pas le positionnement correct des anses. CONCLUSION: Le taux de lentilles infraoculaires correctment positionnées après la fixation trans-sclérale est amélioré avec la choix d'une lentille appropriée et d'une technique nouvelle qui réduit l'angle d'implantation. (Translated by Rob Mack, MD, Iowa City, Iowa.) SOMMARIO PREMESSA: La sutura transclerale per la fissazione della lenti di camera posteriore (PCLs) in assenza del supporto capsulare, provoca minime alterazioni a livello della barriera emato-acqueo a lungo termine, se due condizioni vengono rispettate: la sutura transclerale deve penetrare esattamente attraverso il solco ciliare e la PCL deve essere diretta e posizionata a livello del solco stesso. METODI: I risultati chirurgici delle techniche da nei adottate sono stati controllati intraoperatoriamente effettuando delle endoscopie intraoculari in ciascun paziente, a partire del maggio 1991. Si sono rese necessarie varie manovre procedurali per incrementare l'incidenza dell'impianto nel sulcus capsulare. RISULTATI: Con le nostre tecniche di sutura convenzionale l'ago penetrava nella maggior parte dei casi attraverso i processi ciliari. I migliori risultati sono stati ottenuti passando l'ago dall'esterno verso l'interno del bulbo oculare, prima della sua apertura chirurgica. Quando il bulbo e' già' ipotonico i processi ciliari tendono a prolassarsi al passaggio dell'ago, determinando una fissazione alla pars plicata. Buoni risultati sono stati ad esempio ottenuti nel caso delle cheratoplatiche perforanti facendo passare l'ago dall'interno verso l'esterno fino quando si ha la percezione di attraversare e il sulcus con la punta dell'ago. Comunque anche una corretta penetrazione dell'ago attraverso il sulcus non e' in grado di garantire un corretto posizionamento della PCL a livello del sulcus stesso. CONCLUSIONI: Selezionanado una PCL di disegno adequato ed utilizzando una nuova technica di impianto, capace di ridurre l'angolatura di impianto della PCL, risulta incrementata in modo significativo la possibilità' di posizionare correttamente la PCL con sutura transclerale di fissazione. (Translated by Massimo Ferrari, MD, HSRResnati Eye Clinic, Milan, Italy.)
    Type of Medium: Online Resource
    ISSN: 1081-597X
    Language: English
    Publisher: SLACK, Inc.
    Publication Date: 1993
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...