GLORIA

GEOMAR Library Ocean Research Information Access

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • SAGE Publications  (2)
  • 1
    In: Phlebology: The Journal of Venous Disease, SAGE Publications, Vol. 35, No. 10 ( 2020-12), p. 814-823
    Abstract: Venous leg ulcers, or static leg ulcers, are chronic wounds associated with ambulatory venous hypertension of the lower extremities as a consequence of venous valve reflux, reduce venous capacitance, poor calf venous pump, heart failure, or in conjunction with venous obstruction. A static ulcer with venous thrombosis in a pelvic or thigh vein responds favorably to anticoagulation agents. However, anticoagulation is less effective and even harmful when ambulatory venous hypertension has another cause such as venous reflux, poorly heart function, and poor calf venous pump. Method TRiggered Angiography Non-Contrast-Enhanced (TRANCE) magnetic resonance imaging (MRI) exploits differences in vascular signal intensity during the cardiac cycle for subsequent image subtraction, providing detailed radiation-free venograms without the use of contrast agents. The method is a new tool for evaluating the presence of thrombosis in the venous systems. TRANCE-MRI was employed to document the existence of venous thrombosis within the eight patients in this study. Subsequently, we used a wireless wearable near-infrared spectroscopy device to compare deep vein thrombosis-associated and non-deep vein thrombosis-associated static ulcers. The sampling depths were 5 and 10 mm, representing the dermis and subcutaneous tissue, respectively. Result There are four patients with venous leg ulcers proven with venous thrombosis by TRANCE-MRI and are classified as deep vein thrombosis group. Compared with the non-deep vein thrombosis group, the deep vein thrombosis group had less deoxyhemoglobin, less total hemoglobin, and a significantly lower H 2 O signal in the 5-mm sampling depth (dermis level). And eight health participants were included as control group. Wounded patients (including deep vein thrombosis and non-deep vein thrombosis patients) have higher H 2 O concentration on the 5-mm depth sampling than control group. In the 10-mm sampling depth (subcutaneous level), the deoxyhemoglobin and tissue oxygen saturation of the deep vein thrombosis group were lower than those of the non-deep vein thrombosis group, and the H 2 O concentration was higher than non-deep vein thrombosis group. Patients with static foot ulcers and deep vein thrombosis had similar oxyhemoglobin, deoxyhemoglobin, total hemoglobin, and tissue oxygen saturation than did those without deep vein thrombosis in 5-mm depth sampling (dermis level). Notably, the H 2 O signal of patients with non-deep vein thrombosis-associated static ulcers was higher for the 5-mm sampling depth. Conclusion In patients with static ulcers and deep vein thrombosis, the H 2 O level may be higher in the 10-mm sampling depth, indicating that those patients had more subcutaneous water. In patients with non-deep vein thrombosis static foot ulcer, the near-infrared spectroscopy (NIRS) indicated worse fluid retention in the dermis level. The H 2 O value in the NIRS may be different owing to underline the cause of the venous leg ulcers.
    Type of Medium: Online Resource
    ISSN: 0268-3555 , 1758-1125
    Language: English
    Publisher: SAGE Publications
    Publication Date: 2020
    detail.hit.zdb_id: 1463018-7
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 2
    In: Technology in Cancer Research & Treatment, SAGE Publications, Vol. 20 ( 2021-01-01), p. 153303382110164-
    Abstract: This study performed dosimetry studies and secondary cancer risk assessments on using electronic portal imaging device (EPID) and cone beam computed tomography (CBCT) as image guided tools for the early lung cancer patients treated with SBRT. Methods: The imaging doses from MV-EPID and kV-CBCT of the Edge accelerator were retrospectively added to sixty-one SBRT treatment plans of early lung cancer patients. The MV-EPID imaging dose (6MV Photon beam) was calculated in Pinnacle TPS, and the kV-CBCT imaging dose was simulated and calculated by modeling of the kV energy beam in TPS using Pinnacle automatic modeling program. Three types of plans, namely Plan EPID , Plan CBCT and Plan origin , were generated with incorporating doses of EPID, CBCT and no imaging, respectively, for analysis. The effects of imaging doses on dose-volume-histogram (DVH) and plan quality were analyzed, and the excess absolute risk (EAR) of secondary cancer for ipsilateral lung was evaluated. Results: The regions that received less than 50 cGy were significantly impacted by the imaging doses, while the isodose lines greater than 1000 cGy were barely changed. The DVH values of ipsilateral lung increased the most in Plan EPID , followed by Plan CBCT . Compared to Plan origin on the average, the estimated EAR of ipsilateral lung in Plan EPID increased by 3.43%, while the corresponding EAR increase in Plan CBCT was much smaller (about 0.4%). Considering only the contribution of the imaging dose, the EAR values for the ipsilateral lung due to the MV-EPID dose in 5 years,10 years and 15 years were 1.49 cases, 2.09 cases and 2.88 cases per 10 4 PY respectively, and those due to the kV-CBCT dose were about 9 times lower, correspondingly. Conclusions: The imaging doses produced by MV-EPID and kV-CBCT had little effects on the target dose coverage. The secondary cancer risk caused by MV-EPID dose is more than 8.5 times that of kV-CBCT.
    Type of Medium: Online Resource
    ISSN: 1533-0346 , 1533-0338
    Language: English
    Publisher: SAGE Publications
    Publication Date: 2021
    detail.hit.zdb_id: 2146365-7
    detail.hit.zdb_id: 2220436-2
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...