GLORIA

GEOMAR Library Ocean Research Information Access

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Ovid Technologies (Wolters Kluwer Health)  (4)
  • 1
    In: Investigative Radiology, Ovid Technologies (Wolters Kluwer Health), Vol. 58, No. 4 ( 2023-4), p. 273-282
    Abstract: Diffusion-weighted magnetic resonance imaging (MRI) is increasingly important in patients with multiple myeloma (MM). The objective of this study was to train and test an algorithm for automatic pelvic bone marrow analysis from whole-body apparent diffusion coefficient (ADC) maps in patients with MM, which automatically segments pelvic bones and subsequently extracts objective, representative ADC measurements from each bone. Materials and Methods In this retrospective multicentric study, 180 MRIs from 54 patients were annotated (semi)manually and used to train an nnU-Net for automatic, individual segmentation of the right hip bone, the left hip bone, and the sacral bone. The quality of the automatic segmentation was evaluated on 15 manually segmented whole-body MRIs from 3 centers using the dice score. In 3 independent test sets from 3 centers, which comprised a total of 312 whole-body MRIs, agreement between automatically extracted mean ADC values from the nnU-Net segmentation and manual ADC measurements from 2 independent radiologists was evaluated. Bland-Altman plots were constructed, and absolute bias, relative bias to mean, limits of agreement, and coefficients of variation were calculated. In 56 patients with newly diagnosed MM who had undergone bone marrow biopsy, ADC measurements were correlated with biopsy results using Spearman correlation. Results The ADC-nnU-Net achieved automatic segmentations with mean dice scores of 0.92, 0.93, and 0.85 for the right pelvis, the left pelvis, and the sacral bone, whereas the interrater experiment gave mean dice scores of 0.86, 0.86, and 0.77, respectively. The agreement between radiologists' manual ADC measurements and automatic ADC measurements was as follows: the bias between the first reader and the automatic approach was 49 × 10 −6 mm 2 /s, 7 × 10 −6 mm 2 /s, and −58 × 10 −6 mm 2 /s, and the bias between the second reader and the automatic approach was 12 × 10 −6 mm 2 /s, 2 × 10 −6 mm 2 /s, and −66 × 10 −6 mm 2 /s for the right pelvis, the left pelvis, and the sacral bone, respectively. The bias between reader 1 and reader 2 was 40 × 10 −6 mm 2 /s, 8 × 10 −6 mm 2 /s, and 7 × 10 −6 mm 2 /s, and the mean absolute difference between manual readers was 84 × 10 −6 mm 2 /s, 65 × 10 −6 mm 2 /s, and 75 × 10 −6 mm 2 /s. Automatically extracted ADC values significantly correlated with bone marrow plasma cell infiltration ( R = 0.36, P = 0.007). Conclusions In this study, a nnU-Net was trained that can automatically segment pelvic bone marrow from whole-body ADC maps in multicentric data sets with a quality comparable to manual segmentations. This approach allows automatic, objective bone marrow ADC measurements, which agree well with manual ADC measurements and can help to overcome interrater variability or nonrepresentative measurements. Automatically extracted ADC values significantly correlate with bone marrow plasma cell infiltration and might be of value for automatic staging, risk stratification, or therapy response assessment.
    Type of Medium: Online Resource
    ISSN: 1536-0210 , 0020-9996
    Language: English
    Publisher: Ovid Technologies (Wolters Kluwer Health)
    Publication Date: 2023
    detail.hit.zdb_id: 2041543-6
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 2
    In: Investigative Radiology, Ovid Technologies (Wolters Kluwer Health), Vol. 58, No. 10 ( 2023-10), p. 754-765
    Abstract: In multiple myeloma and its precursor stages, plasma cell infiltration (PCI) and cytogenetic aberrations are important for staging, risk stratification, and response assessment. However, invasive bone marrow (BM) biopsies cannot be performed frequently and multifocally to assess the spatially heterogenous tumor tissue. Therefore, the goal of this study was to establish an automated framework to predict local BM biopsy results from magnetic resonance imaging (MRI). Materials and Methods This retrospective multicentric study used data from center 1 for algorithm training and internal testing, and data from center 2 to 8 for external testing. An nnU-Net was trained for automated segmentation of pelvic BM from T1-weighted whole-body MRI. Radiomics features were extracted from these segmentations, and random forest models were trained to predict PCI and the presence or absence of cytogenetic aberrations. Pearson correlation coefficient and the area under the receiver operating characteristic were used to evaluate the prediction performance for PCI and cytogenetic aberrations, respectively. Results A total of 672 MRIs from 512 patients (median age, 61 years; interquartile range, 53–67 years; 307 men) from 8 centers and 370 corresponding BM biopsies were included. The predicted PCI from the best model was significantly correlated ( P ≤ 0.01) to the actual PCI from biopsy in all internal and external test sets (internal test set: r = 0.71 [0.51, 0.83]; center 2, high-quality test set: r = 0.45 [0.12, 0.69]; center 2, other test set: r = 0.30 [0.07, 0.49]; multicenter test set: r = 0.57 [0.30, 0.76]). The areas under the receiver operating characteristic of the prediction models for the different cytogenetic aberrations ranged from 0.57 to 0.76 for the internal test set, but no model generalized well to all 3 external test sets. Conclusions The automated image analysis framework established in this study allows for noninvasive prediction of a surrogate parameter for PCI, which is significantly correlated to the actual PCI from BM biopsy.
    Type of Medium: Online Resource
    ISSN: 1536-0210 , 0020-9996
    Language: English
    Publisher: Ovid Technologies (Wolters Kluwer Health)
    Publication Date: 2023
    detail.hit.zdb_id: 2041543-6
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 3
    Online Resource
    Online Resource
    Ovid Technologies (Wolters Kluwer Health) ; 2022
    In:  Clinical Orthopaedics & Related Research Vol. 480, No. 8 ( 2022-08), p. 1585-1600
    In: Clinical Orthopaedics & Related Research, Ovid Technologies (Wolters Kluwer Health), Vol. 480, No. 8 ( 2022-08), p. 1585-1600
    Abstract: Wear and corrosion at modular neck tapers in THA can lead to major clinical implications such as periprosthetic osteolysis, adverse local tissue reactions, or implant failure. The material degradation processes at the taper interface are complex and involve fretting corrosion, third-body abrasion, as well as electrochemical and crevice corrosion. One phenomenon in this context is imprinting of the head taper, where the initially smooth surface develops a topography that reflects the rougher neck taper profile. The formation mechanism of this specific phenomenon, and its relation to other observed damage features, is unclear. An analysis of retrieved implants may offer some insights into this process. Questions/purposes (1) Is imprinting related to time in situ of the implants and to the taper damage modes of corrosion and fretting? (2) Are implant design parameters like neck taper profile, stem material, or head seating associated with the formation of imprinting? (3) Is imprinting created by an impression of the neck taper profile or can a different mechanistic explanation for imprinting be derived? Methods Thirty-one THAs with cobalt-chromium-molybdenum-alloy (CoCrMo) heads retrieved between 2013 and 2019 at revision surgery from an institutional registry were investigated. Inclusion criteria were: 12/14 tapers, a head size of 36 mm or smaller, time in situ more than 1 year, and intact nonmodular stems without sleeve adaptors. After grouping the residual THAs according to stem type, stem material, and manufacturer, all groups of three or more were included. Of the resulting subset of 31 retrievals, nine THAs exhibited a still assembled head-neck taper connection. The median (range) time in situ was 5 years (1 to 23). Two stem materials (21 titanium-alloy and 10 stainless steel), three kinds of bearing couples (11 metal-on-metal, 13 metal-on-polyethylene, and seven dual-mobility heads), and two different neck taper profiles (six wavy profile and 25 fluted profile) were present in the collection. Four THAs exhibited signs of eccentric head seating. The 31 investigated THAs represented 21% of the retrieved THAs with a CoCrMo alloy head during the specified period. At the head tapers, the damage modes of corrosion, fretting, and imprinting were semiquantitatively rated on a scale between 0 (no corrosion/fretting/imprinting) and 3 (severe corrosion/fretting/imprinting). Corrosion and fretting were assessed applying the Goldberg score, with the modification that the scale started at 0 and not at 1. Imprinting was assessed with a custom scoring system. Rating was done individually at the proximal and distal head taper half and summed to one total damage score for each retrieval and damage mode. Correlations between the damage modes and time in situ and between the damage modes among each other, were assessed using the Spearman rank order correlation coefficient (ρ). Associations between imprinting and implant design parameters were investigated by comparing the total imprinting score distributions with the Mann-Whitney U-test. Metallographically prepared cross-sections of assembled head-neck taper connections were examined by optical microscopy and disassembled head and neck taper surfaces were assessed by scanning electron microscopy (SEM). Results The imprinting damage score increased with time in-situ (ρ = 0.72; p 〈 0.001) and the corrosion damage score (ρ = 0.63; p 〈 0.001) but not with the fretting damage score (ρ = 0.35; p = 0.05). There was no difference in total imprinting score comparing neck taper profiles or stem materials, with the numbers available. Eccentric head seating had elevated total imprinting score (median 6 [interquartile range 0]) compared with centric seating (median 1 [2] ; p = 0.001). Light optical investigations showed that imprinting can be present on the head taper surfaces even if the depth of abraded material exceeds the neck taper profile height. SEM investigations showed bands of pitting corrosion in the imprinted grooves. Conclusion The microscopic investigations suggest that imprinting is not an independent phenomenon but a process that accompanies the continuous material degradation of the head taper surface because of circular damage on the passive layer induced by grooved neck tapers. Clinical Relevance Material loss from head-neck taper connections involving CoCrMo alloy heads is a source of metal ions and could potentially be reduced if hip stems with smooth neck tapers were used. Surgeons should pay attention to the exact centric seating of the femoral head onto the stem taper during joining of the parts.
    Type of Medium: Online Resource
    ISSN: 0009-921X , 1528-1132
    RVK:
    Language: English
    Publisher: Ovid Technologies (Wolters Kluwer Health)
    Publication Date: 2022
    detail.hit.zdb_id: 2018318-5
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 4
    Online Resource
    Online Resource
    Ovid Technologies (Wolters Kluwer Health) ; 2019
    In:  Investigative Radiology Vol. 54, No. 3 ( 2019-3), p. 146-152
    In: Investigative Radiology, Ovid Technologies (Wolters Kluwer Health), Vol. 54, No. 3 ( 2019-3), p. 146-152
    Abstract: The aim of the study was to determine the quantitative T2 values in prostate tissue and evaluate them for detection and grading of prostate cancer. Materials and Methods After approval from the local ethics committee, morphological T2-weighted (T2w) images, apparent diffusion coefficient (ADC) maps from diffusion-weighted images, quantitative T2 maps, and calculated T2w images from 75 men (median age, 66.3 years; median PSA, 8.2 ng/mL) were acquired at 3 T magnetic resonance imaging (MRI). Data were retrospectively evaluated for their distinction between prostate pathologies. Eight hundred fifty-seven areas of normal gland (n = 378), prostate cancer (54x Gleason score 6, 98x Gleason score 7, 25x Gleason score 8), benign prostatic hyperplasia (BPH) nodes (n = 150), prostatitis (n = 119), and precancerous lesions (n = 33) were determined on calculated and morphological T2w images. Histological criterion standards were whole gland sections (16 patients), MRI-guided in-bore biopsies (32 patients), MRI/transrectal ultrasound-fusion biopsies (15 patients), and systematic 12-core transrectal ultrasound-guided biopsies (12 patients). Significance was assumed to be P 〈 0.05. Results The quantitative T2 values vary significantly between prostate cancer and normal gland tissue (area under the curve [AUC], 0.871), cancer and BPH nodes (AUC = 0.827), and Gleason score 6 and 7 or higher (AUC, 0.742). The quantitative T2 values decrease with increasing Gleason scores and correlate significantly with the ADC values ( r = 0.806). The detection accuracy of prostate cancer on calculated (AUC = 0.682) and morphological T2w images (AUC = 0.658) is not significantly different. Conclusions Quantitative T2 values seem to be suitable for distinguishing between prostate cancer and normal gland tissue or BPH nodes. Similar to the ADC values, they offer an indication of the aggressiveness of the prostate cancer.
    Type of Medium: Online Resource
    ISSN: 1536-0210 , 0020-9996
    Language: English
    Publisher: Ovid Technologies (Wolters Kluwer Health)
    Publication Date: 2019
    detail.hit.zdb_id: 2041543-6
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...