GLORIA

GEOMAR Library Ocean Research Information Access

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Online Resource
    Online Resource
    MDPI AG ; 2019
    In:  Sensors Vol. 19, No. 21 ( 2019-10-26), p. 4656-
    In: Sensors, MDPI AG, Vol. 19, No. 21 ( 2019-10-26), p. 4656-
    Abstract: As a submaximal exercise test, a 6-min walking test (6MWT) can be considered a suitable index for the exercise capacity of patients with a respiratory problem. Traditionally, medical staff manually collect cardiopulmonary information using different devices. However, no integrated monitoring system is currently available to simultaneously record the real-time breathing sound, heart rhythm, and precise walking information (i.e., walking distance, speed, and acceleration) during the 6MWT. In this study, a wearable and wireless multiparameter monitoring system is proposed to simultaneously monitor the breathing sound, oxygen saturation (SpO2), electrocardiograph (ECG) signals, and precise walking information during the 6MWT. Here, a wearable mechanical design was successfully used to reduce the effect of motion artifacts on the breathing sound and ECG signal. A multiparameter detection algorithm was designed to effectively estimate heart and breathing rates. Finally, the cardiopulmonary function of smokers was evaluated using the proposed system. The evaluation indicated that this system could reveal dynamic changes and differences in the breathing rate, heart rate, SpO2, walking speed, and acceleration during the 6MWT. The proposed system can serve as a more integrated approach to monitor cardiopulmonary parameters and obtain precise walking information simultaneously during the 6MWT.
    Type of Medium: Online Resource
    ISSN: 1424-8220
    Language: English
    Publisher: MDPI AG
    Publication Date: 2019
    detail.hit.zdb_id: 2052857-7
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 2
    Online Resource
    Online Resource
    MDPI AG ; 2017
    In:  Sensors Vol. 17, No. 12 ( 2017-01-17), p. 171-
    In: Sensors, MDPI AG, Vol. 17, No. 12 ( 2017-01-17), p. 171-
    Type of Medium: Online Resource
    ISSN: 1424-8220
    Language: English
    Publisher: MDPI AG
    Publication Date: 2017
    detail.hit.zdb_id: 2052857-7
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 3
    In: Micromachines, MDPI AG, Vol. 10, No. 10 ( 2019-10-10), p. 681-
    Abstract: Brain–computer interface (BCI) is a system that allows people to communicate directly with external machines via recognizing brain activities without manual operation. However, for most current BCI systems, conventional electroencephalography (EEG) machines and computers are usually required to acquire EEG signal and translate them into control commands, respectively. The sizes of the above machines are usually large, and this increases the limitation for daily applications. Moreover, conventional EEG electrodes also require conductive gels to improve the EEG signal quality. This causes discomfort and inconvenience of use, while the conductive gels may also encounter the problem of drying out during prolonged measurements. In order to improve the above issues, a wearable headset with steady-state visually evoked potential (SSVEP)-based BCI is proposed in this study. Active dry electrodes were designed and implemented to acquire a good EEG signal quality without conductive gels from the hairy site. The SSVEP BCI algorithm was also implemented into the designed field-programmable gate array (FPGA)-based BCI module to translate SSVEP signals into control commands in real time. Moreover, a commercial tablet was used as the visual stimulus device to provide graphic control icons. The whole system was designed as a wearable device to improve convenience of use in daily life, and it could acquire and translate EEG signal directly in the front-end headset. Finally, the performance of the proposed system was validated, and the results showed that it had excellent performance (information transfer rate = 36.08 bits/min).
    Type of Medium: Online Resource
    ISSN: 2072-666X
    Language: English
    Publisher: MDPI AG
    Publication Date: 2019
    detail.hit.zdb_id: 2620864-7
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 4
    Online Resource
    Online Resource
    MDPI AG ; 2015
    In:  Sensors Vol. 15, No. 3 ( 2015-03-06), p. 5518-5530
    In: Sensors, MDPI AG, Vol. 15, No. 3 ( 2015-03-06), p. 5518-5530
    Abstract: Music is a way of expressing our feelings and emotions. Suitable music can positively affect people. However, current multimedia control methods, such as manual selection or automatic random mechanisms, which are now applied broadly in MP3 and CD players, cannot adaptively select suitable music according to the user’s physiological state. In this study, a brain computer interface-based smart multimedia controller was proposed to select music in different situations according to the user’s physiological state. Here, a commercial mobile tablet was used as the multimedia platform, and a wireless multi-channel electroencephalograph (EEG) acquisition module was designed for real-time EEG monitoring. A smart multimedia control program built in the multimedia platform was developed to analyze the user’s EEG feature and select music according his/her state. The relationship between the user’s state and music sorted by listener’s preference was also examined in this study. The experimental results show that real-time music biofeedback according a user’s EEG feature may positively improve the user’s attention state.
    Type of Medium: Online Resource
    ISSN: 1424-8220
    Language: English
    Publisher: MDPI AG
    Publication Date: 2015
    detail.hit.zdb_id: 2052857-7
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 5
    Online Resource
    Online Resource
    MDPI AG ; 2019
    In:  Sensors Vol. 19, No. 7 ( 2019-03-28), p. 1509-
    In: Sensors, MDPI AG, Vol. 19, No. 7 ( 2019-03-28), p. 1509-
    Abstract: A standard 12-lead electrocardiogram (ECG) is an important tool in the diagnosis of heart diseases. Here, Ag/AgCl electrodes with conductive gels are usually used in a 12-lead ECG system to access biopotentials. However, using Ag/AgCl electrodes with conductive gels might be inconvenient in a prehospital setting. In previous studies, several dry electrodes have been developed to improve this issue. However, these dry electrodes have contact with the skin directly, and they might be still unsuitable for patients with wounds. In this study, a wearable 12-lead electrocardiogram monitoring system was proposed to improve the above issue. Here, novel noncontact electrodes were also designed to access biopotentials without contact with the skin directly. Moreover, by using the mechanical design, this system allows the user to easily wear and take off the device and to adjust the locations of the noncontact electrodes. The experimental results showed that the proposed system could exactly provide a good ECG signal quality even while walking and could detect the ECG features of the patients with myocardial ischemia, installation pacemaker, and ventricular premature contraction.
    Type of Medium: Online Resource
    ISSN: 1424-8220
    Language: English
    Publisher: MDPI AG
    Publication Date: 2019
    detail.hit.zdb_id: 2052857-7
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 6
    In: Diagnostics, MDPI AG, Vol. 12, No. 1 ( 2022-01-05), p. 118-
    Abstract: The progression of clinical manifestations of lower-limb varicose veins remains unclear. This study investigated changes in lower-limb venous blood flow using phase-contrast magnetic resonance angiography. Data were collected on veins from 141 legs. We compared legs with and without varicose veins and related symptoms and examined varying levels of varicose vein symptom severity. Legs without varicose veins exhibited a lower absolute stroke volume (ASV, p 〈 0.01) and mean flux (MF, p = 0.03) for the great saphenous vein (GSV) compared with legs with symptomatic varicose veins. Legs with asymptomatic varicose veins exhibited lower MF for the GSV (p = 0.02) compared with legs with symptomatic varicose veins. Among legs with varicose veins, asymptomatic legs exhibited lower ASV (p = 0.03) and MF (p = 0.046) for the GSV compared with legs that exhibited skin changes or ulcers; however, no significant differences were observed between legs presenting with discomfort or edema and legs with skin changes or ulcers, and between legs presenting with discomfort or edema and asymptomatic legs. In conclusion, in the supine position, increased blood flow rate and blood flow volume in the GSV were associated with symptomatic varicose veins and increased symptom severity.
    Type of Medium: Online Resource
    ISSN: 2075-4418
    Language: English
    Publisher: MDPI AG
    Publication Date: 2022
    detail.hit.zdb_id: 2662336-5
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 7
    In: Medicina, MDPI AG, Vol. 57, No. 8 ( 2021-08-18), p. 835-
    Abstract: Background and Objectives: Compression of the common iliac veins (CIV) is not always associated with lower extremity symptoms. This study analyzed this issue from the perspective of patient venous blood flow changes using quantitative flow magnetic resonance imaging. Materials and Methods: After we excluded patients with active deep vein thrombosis, the mean flux (MF) and mean velocity (MV) of the popliteal vein, femoral vein, and external iliac vein (EIV) were compared between the left and right sides. Results: Overall, 26 of the patients had unilateral CIV compression, of which 16 patients had symptoms. No significant differences were noted in the MF or MV of the veins between the two sides. However, for the 10 patients without symptoms, the EIV MF of the compression side was significantly lower than the EIV MF of the non-compression side (p = 0.04). The receiver operating characteristic curve and chi-squared analyses showed that when the percentage difference of EIV MF between the compression and non-compression sides was ≤−18.5%, the relative risk of associated lower extremity symptoms was 0.44 (p = 0.016). Conclusions: If a person has compression of the CIV, a decrease in EIV blood flow rate on the compression side reduces the rate of symptom occurrence.
    Type of Medium: Online Resource
    ISSN: 1648-9144
    Language: English
    Publisher: MDPI AG
    Publication Date: 2021
    detail.hit.zdb_id: 2088820-X
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 8
    Online Resource
    Online Resource
    MDPI AG ; 2020
    In:  Photonics Vol. 7, No. 3 ( 2020-09-10), p. 71-
    In: Photonics, MDPI AG, Vol. 7, No. 3 ( 2020-09-10), p. 71-
    Abstract: Generally, the diffractive waveguide combiner and computer-generated hologram (CGH) technique have the potential to achieve compact head-mounted display (HMD) with a natural 3D display function. However, the diffractive waveguide combiner will degrade the image quality because of aberration. In order to resolve this issue, the complex analysis based on the ray-tracing method is necessary. Since the major aberration of the waveguide combiners is only astigmatism and anamorphic distortion, only these two aberrations were discussed in this paper. Furthermore, two common waveguide structures were discussed here. In total, four formulas were summarized to analyze aberration and anamorphic distortion in these two structures. Finally, the simplified formulas were verified with the commercial ray-tracing software Zemax. The calculated results of the proposed method match the simulation of Zemax software well. Therefore, the aberration of an arbitrary similar diffractive waveguide can be analyzed by the proposed method. This will make the designing process simpler and faster.
    Type of Medium: Online Resource
    ISSN: 2304-6732
    Language: English
    Publisher: MDPI AG
    Publication Date: 2020
    detail.hit.zdb_id: 2770002-1
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 9
    In: Journal of Personalized Medicine, MDPI AG, Vol. 11, No. 9 ( 2021-08-28), p. 857-
    Abstract: Imaging characteristics of stasis leg ulcers (SLUs) are not easily demonstrated through existing diagnostic tools. Early diagnosis and treatment are crucial. This pilot study was conducted to assess the quantitative flow (QFlow) in triggered angiography noncontrast enhanced (TRANCE) magnetic resonance imaging (MRI) to identify the hemodynamics of victims with stasis leg ulcers (SLUs). This study included 33 patients with SLUs and 14 healthy controls (HC). The 33 patients with SLUs were divided into a reflux (15 patients) and a nonreflux group (18 patients). QFlow was done in the reflux, the nonreflux, and the HC. The stroke volume (SV), forward flow volume (FFV), absolute flow volume (AFV), mean flow (MF), and mean velocity (MV) were higher in the reflux than in the HC group in most segments, namely the external iliac vein (EIV), popliteal vein (PV), and great saphenous vein (GSV) (SV, p = 0.008; FFV, p = 0.008; absolute stroke volume (ASV), p = 0.008; MF, p = 0.002; MV, p = 0.009). No differences in the QFlow patterns were found in the GSV segment between the nonreflux group and the HC. Excellent performance in discriminating SLU with superficial venous reflux was reported for SV in the EIV and the PV (area under the curve (AUC) = 0.851 and 0.872), FFV in the EIV and PV (AUC = 0.854 and 0.869), ASV in the EIV and PV (AUC = 0.848 and 0.881), and MF in the EIV and PV (AUC = 0.866 and 0.868). The cutoff levels of SV/FFV/ASV/MF in the EIV/FV/PV/GSV for discriminating the SLU with superficial venous reflux were identified (p 〈 0.005). In conclusion, SLUs present different QFlow patterns by different etiology. The QFlow parameters of all vessel segments were higher in the morbid limbs of the reflux group than HC. The GSV segment of the nonreflux group displayed a pattern like the HC.
    Type of Medium: Online Resource
    ISSN: 2075-4426
    Language: English
    Publisher: MDPI AG
    Publication Date: 2021
    detail.hit.zdb_id: 2662248-8
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 10
    In: Diagnostics, MDPI AG, Vol. 10, No. 6 ( 2020-05-29), p. 355-
    Abstract: Objectives: Venous diseases in the lower extremities long lacked an objective diagnostic tool prior to the advent of the triggered angiography non-contrast-enhanced (TRANCE) technique. Methods: An observational study with retrospective data analysis. Materials: Between April 2017 and June 2019, 66 patients were evaluated for venous diseases through TRANCE-magnetic resonance imaging (MRI) and were grouped according to whether they had occlusive venous (OV) disease, a static venous ulcer (SU), or symptomatic varicose veins (VV). The clinical appliance of TRANCE-MRI was analysed by groups. Results: In total, 63 patients completed the study. TRANCE-MRI could identify venous thrombosis, including that of the abdominal and pelvic vessels, and it enabled the timely treatment of underlying diseases in patients with OV disease. TRANCE-MRI was statistically compared with the duplex scan, the gold standard to exclude deep vein thrombosis (DVT) in the legs, with regard to their abilities to detect venous thrombosis by using Cohen’s kappa coefficient at a compatible value of 0.711. It could provide the occlusion degree of the peripheral artery for treating an SU. Finally, TRANCE-MRI can be used to outline all collateral veins and occult thrombi before treating symptomatic or recurrent VV to ensure a perfect surgical plan and to avoid complications. Conclusions: TRANCE-MRI is an innovative tool in the treatment of versatile venous pathology in the lower extremities and is widely used for vascular diseases in our institution.
    Type of Medium: Online Resource
    ISSN: 2075-4418
    Language: English
    Publisher: MDPI AG
    Publication Date: 2020
    detail.hit.zdb_id: 2662336-5
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...