GLORIA

GEOMAR Library Ocean Research Information Access

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    In: Diagnostics, MDPI AG, Vol. 12, No. 8 ( 2022-08-04), p. 1894-
    Abstract: Objective: To assess the reliability of the myeloma spine and bone damage score (MSBDS) across multiple readers with different levels of expertise and from different institutions. Methods: A reliability exercise, including 104 data sets of static images and complete CT examinations of patients affected by multiple myeloma (MM), was performed. A complementary imaging atlas provided detailed examples of the MSBDS scores, including low-risk and high-risk lesions. A total of 15 readers testing the MSBDS were evaluated. ICC estimates and their 95% confidence intervals were calculated based on mean rating (k = 15), absolute agreement, a two-way random-effects model and Cronbach’s alpha. Results: Overall, the ICC correlation coefficient was 0.87 (95% confidence interval: 0.79–0.92), and the Cronbach’s alpha was 0.93 (95% confidence interval: 0.94–0.97). Global inter- and intra-observer agreement among the 15 readers with scores below or equal to 6 points and scores above 6 points were 0.81 (95% C.I.: 0.72–0.86) and 0.94 (95% C.I.:0.91–0.98), respectively. Conclusion: We present a consensus-based semiquantitative scoring systems for CT in MM with a complementary CT imaging atlas including detailed examples of relevant scoring techniques. We found substantial agreement among readers with different levels of experience, thereby supporting the role of the MSBDS for possible large-scale applications. Significance and Innovations • Based on previous work and definitions of the MSBDS, we present real-life reliability data for quantitative bone damage assessment in multiple myeloma (MM) patients on CT. • In this study, reliability for the MSBDS, which was tested on 15 readers with different levels of expertise and from different institutions, was shown to be moderate to excellent. • The complementary CT imaging atlas is expected to enhance unified interpretations of the MSBDS between different professionals dealing with MM patients in their routine clinical practice.
    Type of Medium: Online Resource
    ISSN: 2075-4418
    Language: English
    Publisher: MDPI AG
    Publication Date: 2022
    detail.hit.zdb_id: 2662336-5
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 2
    In: Diagnostics, MDPI AG, Vol. 12, No. 9 ( 2022-09-08), p. 2170-
    Abstract: Mammography is the gold standard examination for breast cancer screening. In women with high breast density, mammography has reduced sensitivity. In these women, an additional screening option is often recommended. This study prospectively compared ABVS and HHUS in women with mammography-negative examinations and dense breasts. Materials and methods: N = 222 women were evaluated prospectively and consecutively between January 2019 and June 2019 (average age 53 years; range 39–89). McNemar’s test and ROC analysis were used with standard statistical software. We included in the study both symptomatic and asymptomatic women with dense breasts. Women included underwent both HHUS and ABVS after mammography with independent reading. Results: N = 33/222 (15%) women resulted in having breast cancer. Both ABVS and HHUS identified more cancers than standard mammography, and both HHUS and ABVS had false-positive examinations: n = 13 for HHUS and n = 12 for ABVS. We found that HHUS had better accuracy than ABVS. The AUC of the ROC was 0.788 (95% CI 0.687–0.890) for ABVS and 0.930 (95% CI 0.868–0.993) for HHUS. This difference was statistically significant (p 〈 0.05). Conclusions: HHUS was more accurate in breast cancer detection than ABVS. Multicentric studies must confirm these data for supplemental imaging in women with dense breasts.
    Type of Medium: Online Resource
    ISSN: 2075-4418
    Language: English
    Publisher: MDPI AG
    Publication Date: 2022
    detail.hit.zdb_id: 2662336-5
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...