GLORIA

GEOMAR Library Ocean Research Information Access

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Journal of New Materials for Electrochemical Systems  (1)
Material
Publisher
  • Journal of New Materials for Electrochemical Systems  (1)
Language
Years
  • 1
    Online Resource
    Online Resource
    Journal of New Materials for Electrochemical Systems ; 2021
    In:  Journal of New Materials for Electrochemical Systems Vol. 24, No. 2 ( 2021-6-30), p. 84-94
    In: Journal of New Materials for Electrochemical Systems, Journal of New Materials for Electrochemical Systems, Vol. 24, No. 2 ( 2021-6-30), p. 84-94
    Abstract: This paper is focused on design and application of Pseudo-Derivative Feedback (PDF) controller for Automatic Generation Control (AGC) of a two-area thermal reheat interconnected power system treated in deregulated condition. The proposed controller gains are tuned simultaneously using Flower Pollination Algorithm (FPA) in order to achieve the optimal transient response of the test system. The control performance of the PDF controller is compared with Proportional Integral (PI) and Proportional Integral Derivative (PID) controllers. Further to improve the AGC performance, Hydrogen Energy Storage (HES) are included in its control area. The execution of HES unit captures the underlying fall in frequency as well as the tie line control power deviations after a sudden load unsettling influence. The simulation results demonstrate that the proposed PDF controller enhance the dynamic response of the deregulated power system as compared with PI and PID contrtoller. The frequency oscillation and tie-line power deviations in the control zones are reduced and the settling time is additionally enhanced when HES unit takes an interest in the frequency regulation along with the traditional generators. Additionally, the Power System Restoration Indices (PSRI) is figured in view of system dynamic performances and the remedial measures to be taken can be decreed. These PSRI shows that the ancillary service requirement to enhances the effectiveness of physical task of the power system with the expanded transmission limit in the system. The presence of an Hydrogen Energy Storage (HES) water electrolyser coupled to a fuel cell improves significantly the control and operation of an energy system and provides good margin of stability of the grid system compared to that a system without HES unit.
    Type of Medium: Online Resource
    ISSN: 1480-2422 , 2292-1168
    URL: Issue
    Language: Unknown
    Publisher: Journal of New Materials for Electrochemical Systems
    Publication Date: 2021
    detail.hit.zdb_id: 2149759-X
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...