GLORIA

GEOMAR Library Ocean Research Information Access

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Publication Date: 2022-05-26
    Description: © The Author(s), 2019. This article is distributed under the terms of the Creative Commons Attribution License. The definitive version was published in Du, J., Park, K., Yu, X., Zhang, Y. J., & Ye, F. Massive pollutants released to Galveston Bay during Hurricane Harvey: Understanding their retention and pathway using Lagrangian numerical simulations. Science of the Total Environment, 704, (2019): 135364, doi: 10.1016/j.scitotenv.2019.135364.
    Description: Increasing frequency of extreme precipitation events under the future warming climate makes the storm-related pollutant release more and more threatening to coastal ecosystems. Hurricane Harvey, a 1000-year extreme precipitation event, caused massive pollutant release from the Houston metropolitan area to the adjacent Galveston Bay. 0.57 × 106 tons of raw sewage and 22,000 barrels of oil, refined fuels and chemicals were reportly released during Harvey, which would likely deteriorate the water quality and damage the coastal ecosystem. Using a Lagrangian particle-tracking method coupled with a validated 3D hydrodynamic model, we examined the retention, pathway, and fate of the released pollutants. A new timescale, local exposure time (LET), is introduced to quantitatively evaluate the spatially varying susceptibility inside the bay and over the shelf, with a larger LET indicating the region is more susceptible to the released pollutants. We found LET inside the bay is at least one order of magnitude larger for post-storm release than storm release due to a quick recovery in the system's flushing. More than 90% of pollutants released during the storm exited the bay within two days, while those released after the storm could stay inside the bay for up to three months. This implies that post-storm release is potentially more damaging to water quality and ecosystem health. Our results suggest that not only the amount of total pollutant load but also the release timing should be considered when assessing a storm's environmental and ecological influence, because there could be large amounts of pollutants steadily and slowly discharged after storm through groundwater, sewage systems, and reservoirs.
    Description: We like to acknowledge the Texas Coastal Management Program, the Texas General Land Office and NOAA for partial funding of this project through CMP Contract #19-040-000-B074. This work was performed using computing facilities at the College of William and Mary, which were provided by contributions from the National Science Foundation, the Commonwealth of Virginia Equipment Trust Fund and the Office of Naval Research.
    Keywords: Storm discharge ; Retention ; Local exposure time ; Particle tracking ; SCHISM
    Repository Name: Woods Hole Open Access Server
    Type: Article
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    Journal of esthetic and restorative dentistry 2 (1990), S. 0 
    ISSN: 1708-8240
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: Four different finishing techniques were used in a dentin bonding agent/composite resin restoration to evaluate the possible influence of finishing technique on microleakage. Results indicated that finishing technique affects the ability of the restorative system to resist microleakage. Under the conditions of this study, best results were achieved with a 30-fluted bur followed by a short wet polish. Samples finished dry with polishing disks demonstrated considerable microleakage. This study also suggests that homogeneous nonagglomerated microfilled composite resin does not require disk finishing.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    Journal of esthetic and restorative dentistry 2 (1990), S. 0 
    ISSN: 1708-8240
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: This study evaluates the effects of six composite resins, which use three different curing systems, on the ability of Tenure to resist microleakage. The curing systems were a photoinitiated dual-cure system, a dual-cure system, and light-cure systems. A total of 39 human molars were used. Following 2,000 cycles on a thermocycler, specimens were exposed to 0.2 percent basic fuchsin dye for 24 hours and then examined for microleakage. Results indicated that the composite resin plays an important role in the ability of a restorative system to resist microleakage. The photoinitiated dual-cure system produced significantly less microleakage than light-activated systems. No difference in microleakage was found between light-activated systems and the dual-cure system.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    Journal of esthetic and restorative dentistry 4 (1992), S. 0 
    ISSN: 1708-8240
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: Marginal leakage in amalgam restorations often precedes the development of secondary caries. One potential way to improve the marginal seal of such restorations, and thus minimize the risk of carles development, is to apply a glassionomer base prior to amalgam placement.This study compared microleakage resistance among amalgam restorations placed with and without light-cured glass-ionomer base materials. Preparations were made in extracted human molar teeth. Four groups were studied, including copal varnish, which was used as a control. All specimens were restored with amalgam. Results indicated significantly greater leakage at the cavity wall/base interface for restorations with a copal varnish cavity liner than for those with a glass-ionomer base. Leakage differences among bases were also found at the amalgam/base interface. Best results were obtained with a dual-cure resin-based system. These samples showed minimal leakage at both the cavity wall/base and the base/amalgam interfaces. These findings suggest that light-cured glass-ionomer bases can be effective in the prevention of microleakage in amalgam restorations.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    Journal of esthetic and restorative dentistry 1 (1989), S. 0 
    ISSN: 1708-8240
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Amsterdam : Elsevier
    Phytochemistry 28 (1989), S. 1774-1776 
    ISSN: 0031-9422
    Keywords: 2S,5S,-bis-(3,4-dimethoxyphenyl)-3R,4S-dimethyltetrahydrofuran. ; Schisandra sphenanthera ; Schisandraceae ; ganschisandrine ; lignan
    Source: Elsevier Journal Backfiles on ScienceDirect 1907 - 2002
    Topics: Biology , Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Amsterdam : Elsevier
    Solid State Communications 69 (1989), S. 945-948 
    ISSN: 0038-1098
    Source: Elsevier Journal Backfiles on ScienceDirect 1907 - 2002
    Topics: Physics
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Amsterdam : Elsevier
    Chinese Astronomy 2 (1978), S. 193-209 
    ISSN: 0146-6364
    Source: Elsevier Journal Backfiles on ScienceDirect 1907 - 2002
    Topics: Physics
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...