GLORIA

GEOMAR Library Ocean Research Information Access

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Blackwell Publishing Ltd  (785)
  • American Physical Society (APS)  (260)
Document type
  • 1
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    Journal of esthetic and restorative dentistry 17 (2005), S. 0 
    ISSN: 1708-8240
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: Surface wear can be a problem with directly placed composites.〈section xml:id="abs1-3"〉〈title type="main"〉Purpose:: This study evaluated the in vitro wear and surface roughness of two composites at different cycle intervals after being subjected to toothbrush-dentifrice abrasion.〈section xml:id="abs1-4"〉〈title type="main"〉Materials and Methods: Twenty specimens of a microhybrid, Filtek Z250 (3M ESPE, St. Paul, MN, USA), and a nanofill composite, Filtek Supreme (3M ESPE), were prepared according to the manufacturer's directions. Each specimen was subjected to toothbrush-dentifrice abrasion (250 g vertical load) using a deionized water-dentifrice slurry (Close-Up, Lever Ponds Ltd., La Lucia, ZA) and toothbrush heads (Oral-B 40, Oral-B Laboratories, Delmont, CA, USA). A brushing sequence of 10,000, 20,000, 50,000, and 100,000 strokes was performed for all samples at a rate of 1.5 Hz. At baseline and each cycle interval, a surface profilometer was used to determine average surface roughness, Ra. At the same intervals, vertical loss of material was measured with a precision micrometer. Data were analyzed using repeated-measures analysis of variance at p value .05. Analyses with atomic force microscopy (AFM) and scanning electron microscopy (SEM) were also performed.Results: After 20,000, 50,000, and 100,000 cycles, Filtek Supreme showed less significant wear than Z250. Filtek Supreme demonstrated higher surface roughness than Z250 after 50,000 and 100,000 cycles. However, AFM and SEM images indicated a more uniform surface topography for Filtek Supreme than for Z250. Abrasion wear and surface roughness increased with each cycle interval for both materials.Conclusions: Although the initial performance of both materials was similar, a greater number of brushing cycles revealed differences between the wear resistance and generated surface roughness of the materials.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    Annals of the New York Academy of Sciences 686 (1993), S. 0 
    ISSN: 1749-6632
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Natural Sciences in General
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    Histopathology 27 (1995), S. 0 
    ISSN: 1365-2559
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: Plasminogen activator inhibitors are thought to be responsible for the abolition of fibrinolytic activity in inflamed peritoneum. This reduction in the fibrin clearing capacity of the peritoneum promotes the formation of intraabdominal adhesions. High concentrations of plasminogen activator inhibitor-2 (PAI-2) have been previously found in inflamed peritoneal tissue using immunoassays, but it is undetectable in normal peritoneum. The aim of this study was to localize plasminogen activator inhibitor-2 production in tissue by in situ mRNA hybridisation. Sections of normal and inflamed human appendix were hybridised with a digoxigenin labelled cDNA probe. In normal appendix staining was confined to macrophages in the mucosa. Macrophage staining was also seen in inflamed tissue but with a wider distribution throughout the appendix wall. PAI-2 was also localized to mesothelial cells of inflamed but not normal appendix. Cell identities were confirmed using immunohistochemistry directed against cell specific markers. Staining was absent from control slides incubated with plasmid DNA or PAI-2 probe following ribonuclease digestion. The identification of the cells expressing the PAI-2 gene in peritoneum increases our understanding of the pathophysiological process leading to fibrin deposition within the abdomen during peritonitis.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    Journal of prosthodontics 4 (1995), S. 0 
    ISSN: 1532-849X
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: Purpose This study evaluated the bond strength and bond durability of new adhesive systems to pure titanium.Materials and Methods Plexiglass tubes filled with composite were bonded to titanium discs. Groups of 24 samples were bonded using six different bonding systems. Subgroups of eight bonded samples were stored in an isotonic artificial saliva solution (37°C) for 1, 30, or 150 days. In addition, the 30- and 150-day samples were thermal cycled for 7,500 or 37,500 cycles between 5°C and 55°C, respectively. After these storage conditions, all samples were debonded in tension.Results The bond strength of a conventional bisphenol-A glycidyl methacrylate composite to sandblasted titanium was significantly lower than using chemomechanical bonding systems and decreased slightly during the storage time of 150 days. The additional use of a silane on sandblasted titanium resulted in an insignificant increase in bond strength and decreased over storage time to the same level as on sandblasted-only titanium. Statistically significant higher bond strengths were achieved either with the combination of silica coating and use of a conventional bisphenol-A glycidyl methacrylate composite or with the combination of sandblasting and the use of composites modified with a phosphate monomer. In the latter systems, the bond strengths were only limited by the cohesive strength of the composite resins. A new phosphate monomer containing composite showed a tendency to lose cohesive strength over time (statistically not significant).Conclusions Using chemomechanical bonding systems, ie, silica-coating systems or modified composites with adhesive monomers, resulted in 2 to 2.5 times increased bond strength to titanium compared with the bond strength of a conventional bisphenol-A glycidyl methacrylate composite. With chemomechanical bonding systems, the resin bond to titanium was durable over 150 days, even after being stored in water and thermal cycled.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    Risk analysis 19 (1999), S. 0 
    ISSN: 1539-6924
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Energy, Environment Protection, Nuclear Power Engineering
    Notes: Risk assessors often use different probability plots as a way to assessthe fit of a particular distribution or model by comparing the plotted points to a straight line and to obtain estimates of the parameters in parametric distributions or models. When empirical data do not fall in a sufficiently straight line on a probability plot, and when no other single parametricdistribution provides an acceptable (graphical) fit to the data, the risk assessor may consider a mixture model with two component distributions. Animated probability plots are a way to visualize the possible behaviors of mixture models with two component distributions. When no single parametric distribution provides an adequate fit to an empirical dataset, animated probability plots can help an analyst pick some plausible mixture models for the data based on their qualitative fit. After using animations during exploratory data analysis, the analyst must then use other statistical tools, including but not limited to: Maximum Likelihood Estimation (MLE) to find the optimal parameters, Goodness of Fit (GoF) tests, and a variety of diagnostic plots to check the adequacy of the fit. Using a specific example with two LogNormal components, we illustrate the use of animated probability plots asa tool for exploring the suitability of a mixture model with two component distributions. Animations work well with other types of probability plots, and they may be extended to analyze mixture models with three or more component distributions.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    Risk analysis 19 (1999), S. 0 
    ISSN: 1539-6924
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Energy, Environment Protection, Nuclear Power Engineering
    Notes: Much has been written about the development and application of quantitative methods for estimating under uncertainty the long-term radiological performance of underground disposal of radioactive wastes. Until recently, interest has been focused almost entirely on the technical challenges regardless of the role of the organization responsible for these analyses. Now the dialogue between regulators, the repository developer or operator, and other interested parties in the decision-making process receives increasing attention, especially in view of some current difficulties in obtaining approvals to construct or operate deep facilities for intermediate or high-level wastes. Consequently, it is timely to consider the options for regulators’review and evaluation of safety submissions, at the various stages in the site selection to repository closure process, and to consider, especially, the role for performance assessment (PA) within the programs of a regulator both before and after delivery of such a submission. The origins and broad character of present regulations in the European Union (EU) and in the OECD countries are outlined and some regulatory PA reviewed. The issues raised are discussed, especially in regard to the interpretation of regulations, the dangers from the desire for simplicity in argument, the use of regulatory PA to review and challenge the PA in the safety case, and the effects of the relationship between proponent and regulator. Finally, a very limited analysis of the role of PA in public hearings is outlined and recommendations are made, together with proposals for improving the mechanisms for international collaboration on technical issues of regulatory concern.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    The @breast journal 2 (1996), S. 0 
    ISSN: 1524-4741
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    Journal of metamorphic geology 4 (1986), S. 0 
    ISSN: 1525-1314
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Geosciences
    Notes: MIGMATITES
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 9
    ISSN: 1527-3458
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    Journal of metamorphic geology 5 (1987), S. 0 
    ISSN: 1525-1314
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Geosciences
    Notes: Abstract Chloritoid–hornblende occurs in quartz–muscovite pelitic schist derived from sediment in a volcaniclastic sequence of the Grenville Supergroup and from reworked sedimentary and regolithic material above the unconformity at the base of the Flinton Group. Comparison of these samples with other pelitic rocks on triangular composition diagrams and in the ACNF and ACFM tetrahedra indicates that the presence of hornblende cannot be explained by unusually high CaO content. The rare assemblage is attributed to a combination of relatively low Al2O3 and high K2O with high CaO/(CaO+Na2O) and FeO/(FeO+MgO).On two qualitative reaction grids derived from AFM diagrams projected through CaO and plagioclase, respectively, the P–T stability field of chloritoid–hornblende overlaps the first appearance of staurolite–biotite in normal pelitic rocks in the kyanite field. Staurolite–hornblende overlaps chloritoid–hornblende and extends to the higher temperatures and pressures of the kyanite–hornblende field.The phase relations in these rocks provide a link between the conventional hornblende-absent grids for pelitic rocks and those for K2O-poor (muscovite-absent) pelitic and mafic amphibolitic rocks.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...