GLORIA

GEOMAR Library Ocean Research Information Access

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    facet.materialart.
    Unknown
    Springer
    In:  Marine Geophysical Researches, 20 (3). pp. 239-247.
    Publication Date: 2018-02-08
    Description: Bottom shots have been used for a number of years in seismic studies on the ocean floor. Most experiments utilized explosives as the energy source, though researchers have recognized the usefulness of collapsing water voids to produce seismoacoustic signals. Implosive sources, however, suffered generally from a lack of control of source depth. We present a new experimental tool, called SEEBOSEIS, to carry out seismic experiments on the seafloor utilizing hollow glass spheres as controlled implosive sources. The source is a 10-inch BENTHOS float with penetrator. Inside the sphere we place a small explosive charge (two detonators) to destabilize the glass wall. The time of detonation is controlled by an external shooting device. Test measurements on the Ninetyeast Ridge, Indian Ocean, show that the implosive sources can be used in seismic refraction experiments to image the subbottom P- wave velocity structure in detail beyond that possible with traditional marine seismic techniques. Additionally, the implosions permit the efficient generation of dispersed Scholte waves, revealing upper crustal S-wave velocities. The frequency band of seismic energy ranges from less than 1 Hz for Scholte modes up to 1000 Hz for diving P-waves. Therefore, broadband recording units with sampling rates 〉2000 Hz are recommended to sample the entire wave field radiated by implosive sources.
    Type: Article , PeerReviewed
    Format: text
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 56 (1985), S. 1593-1596 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: The temperature dependence of four characteristic infrared absorptions accompanying phase transitions in three molecular solids have been used as "infrared thermometers'' to estimate the thermal lag of KBr pellets held in an Invar sample cell in a Fourier transform infrared spectrometer at (variable) cryogenic temperatures. Due to the low power deposition on the sample in a typical FTIR spectrometer, thermal lags of less than 0.5 K can be routinely achieved at temperatures in the range 77≤T≤300 K.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    College Park, Md. : American Institute of Physics (AIP)
    The Journal of Chemical Physics 104 (1996), S. 7-10 
    ISSN: 1089-7690
    Source: AIP Digital Archive
    Topics: Physics , Chemistry and Pharmacology
    Notes: Detailed 57Fe Mossbauer experiments over the range 85〈T〈210 K have been carried out on the tetra-carbonyl iron derivative of C60(I) as well as on several related organometallic solids. The observed isomer shift and quadrupole splitting parameters are consistent with a bonding interaction between the metal center and the ligand which involves a single carbon–carbon double bond of the buckminsterfullerene. The temperature dependence of the recoil-free fraction, compared to analogous data for maleic anhydride Fe(CO)4(II), suggests that the two previously observed low frequency lattice modes in C60 persist in I. Contrary to expectations, there is no significant temperature-dependent vibrational anisotropy (Gol'danskii–Karyagin effect) evident in the above temperature range. © 1996 American Institute of Physics.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Springer
    Marine geophysical researches 8 (1986), S. 175-186 
    ISSN: 1573-0581
    Source: Springer Online Journal Archives 1860-2000
    Topics: Geosciences , Physics
    Notes: Abstract A simple, low cost, deep-towed system for high-resolution reflection seismic profiling is described. It consists of a vertical array with two hydrophones having a separation of 2.2 m and rigidly mounted onto streamlined tow bodies. Improvement of the signal-to-noise ratio is attained by simple stacking of the hydrophone outputs after signal conditioning and travel time corrections. The suppression of side echoes and surface reflections is achieved by an analog procedure which in effect improves the directional characteristics of the array. A circuit for automatic gain control is included to enhance weak signals as well as to suppress ringing. Results in Kiel Bay and over the crest of the Jan Mayen Ridge (northern Atlantic) suggest that this simple vertical array may supplement air gun systems better than conventional, surface pinger-type equipment.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Springer
    Marine geophysical researches 6 (1984), S. 433-446 
    ISSN: 1573-0581
    Source: Springer Online Journal Archives 1860-2000
    Topics: Geosciences , Physics
    Notes: Abstract The Techniques of the IFG Hamburg for the use and handling of chemical sources for seismic energy generation are described. The results of normal and dispersed charge shooting in marine and combined land/sea projects are presented and it is shown, that the introduction of a clock based shooting technique leads to more efficiency for dispersed charges. The increase of safety and the economizing of explosives are outlined.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Springer
    Marine geophysical researches 19 (1997), S. 257-265 
    ISSN: 1573-0581
    Keywords: Shot-induced noise ; shot interval ; seismic refraction ; S/N ratio
    Source: Springer Online Journal Archives 1860-2000
    Topics: Geosciences , Physics
    Notes: Abstract Seismic noise induced by the seismic source during continuous profiling reduces the signal-to-noise ratio and hence the data quality. This noise is largely dependent on the shot interval. In this paper, the noise amplitude of refraction seismic records from a special experiment is analysed as a function of the shot interval. An empirical exponential relationship between mean peak noise amplitude and shot interval is deduced. By increasing the shot interval, the induced noise can be minimized on all successive records. This results in an improvement of the data, predominantly the signal-to-noise ratio. Because the seismic signal and the shot-induced noise have nearly the same spectra, the chance of improving the signal-to-noise ratio by stacking is significantly reduced.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Springer
    Marine geophysical researches 20 (1998), S. 239-247 
    ISSN: 1573-0581
    Keywords: bottom shots ; implosive sources ; P-waves ; Scholte waves ; seismic velocities
    Source: Springer Online Journal Archives 1860-2000
    Topics: Geosciences , Physics
    Notes: Abstract Bottom shots have been used for a number of years in seismic studies on the ocean floor. Most experiments utilized explosives as the energy source, though researchers have recognized the usefulness of collapsing water voids to produce seismoacoustic signals. Implosive sources, however, suffered generally from a lack of control of source depth. We present a new experimental tool, called SEEBOSEIS, to carry out seismic experiments on the seafloor utilizing hollow glass spheres as controlled implosive sources. The source is a 10-inch BENTHOS float with penetrator. Inside the sphere we place a small explosive charge (two detonators) to destabilize the glass wall. The time of detonation is controlled by an external shooting device. Test measurements on the Ninetyeast Ridge, Indian Ocean, show that the implosive sources can be used in seismic refraction experiments to image the subbottom P-wave velocity structure in detail beyond that possible with traditional marine seismic techniques. Additionally, the implosions permit the efficient generation of dispersed Scholte waves, revealing upper crustal S-wave velocities. The frequency band of seismic energy ranges from less than 1 Hz for Scholte modes up to 1000 Hz for diving P-waves. Therefore, broadband recording units with sampling rates 〉2000 Hz are recommended to sample the entire wave field radiated by implosive sources.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Springer
    Marine geophysical researches 4 (1979), S. 247-253 
    ISSN: 1573-0581
    Source: Springer Online Journal Archives 1860-2000
    Topics: Geosciences , Physics
    Notes: Abstract The ocean bottom seismograph (OBS) of the Institut für Geophysik, Hamburg (IfG) is designed for refraction seismic experiments and for recording microseismic noise. Hydrophone signals are recorded directly on a casette tape recorder with a band width of 3–60 Hz. Signals from three component 1 Hz seismometers are recorded on a 2nd casette tape recorder in FM for a frequency range of 0.1–1 Hz. A telemetering buoy at the surface is connected with the OBS by a polypropylene rope.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Springer
    Il nuovo cimento della Società Italiana di Fisica 18 (1996), S. 227-230 
    ISSN: 0392-6737
    Keywords: Mössbauer spectra ; Mössbauer effect ; other γ-ray spectroscopy ; Crystalline state (including molecular motions in solids) ; Conference proceedings
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Summary C60 (Buckminsterfullerene) is isolated from organic solvents above 260 K as an f.c.c. solid with complete orientational disorder. The rotational dynamics are diffuse and isotropic, with a short (12 ps) correlation time at 300 K. Below 260 K, the solid forms in a simple cubic lattice withPa3 symmetry. The librational motion occurs by activated jumps with a correlation time of about 60 ns at 200 K. To gain further insight into the dynamics of C60, the compound C60Fe(CO)4 (I) (generously made available to us by A. Stephens and M. Green of Oxford University) has been studied by57Fe Mössbauer spectroscopy. As expected, the resonance at 90 K consists of a doublet with an isomer shift (relative to metallic iron) of 0.034(1) mm s−1 and a quadrupole splitting of 1.607(5) mm s−1. There is no significant temperature-dependent, intensity asymmetry of the doublet. The temperature dependence of the effect magnitude is well fit by a linear regression over the range 85〈T〈210 K. To elucidate the relationship of these results to the effect of the C60 moiety in I, further lattice dynamical Mössbauer studies have been carried out on (maleic anhydride) Fe(CO)4 (II), one of the few isolatable tetracarbonyl complexes of iron. For (II), the quadrupole splitting is 1.371(5) mm s−1 at 90 K, and the temperature, dependence of the isomer shift is smaller than it is for (I), while the temperature dependence of the recoil-free fraction is significantly larger in (I) than in (II).
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Springer
    International archives of occupational and environmental health 38 (1976), S. 115-120 
    ISSN: 1432-1246
    Keywords: Carbon disulphide ; Methods ; Exposure
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary The commonly-used iodo-azide test (IAT) for exposure to carbon disulphide is compared with two new gaschromatographic (GLC) methods. The GLC methods are consistent with each other, but not consistent with the IAT. The urine values of 23 exposed and 6 non-exposed workers were compared with the results of the IAT and the two GLC methods. The conclusion was that GLC methods are better suited for measuring in urine at low exposure for qualitative purposes.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...