GLORIA

GEOMAR Library Ocean Research Information Access

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    350 Main Street , Malden , MA 02148-5018 , USA , and 9600 Garsington Road , Oxford OX4 2DQ , UK . : Blackwell Science Inc
    Journal of cardiovascular electrophysiology 16 (2005), S. 0 
    ISSN: 1540-8167
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: Background: The objective of this study was to compare transtelephonic ECG every 2 days and serial 7-day Holter as two methods of follow-up after atrial fibrillation (AF) catheter ablation for the judgment of ablation success. Patients with highly symptomatic AF are increasingly treated with catheter ablation. Several methods of follow-up have been described, and judgment on ablation success often relies on patients' symptoms. However, the optimal follow-up strategy objectively detecting most of the AF recurrences is yet unclear. Methods: Thirty patients with highly symptomatic AF were selected for circumferential pulmonary vein ablation. During follow-up, a transtelephonic ECG was transmitted once every 2 days for half a year. Additionally, a 7-day Holter was recorded preablation, after ablation, after 3 and 6 months, respectively. With both, procedures symptoms and actual rhythm were correlated thoroughly. Results: A total of 2,600 transtelephonic ECGs were collected with 216 of them showing AF. 25% of those episodes were asymptomatic. On a Kaplan-Meier analysis 45% of the patients with paroxysmal AF were still in continuous SR after 6 months. Simulating a follow-up based on symptomatic recurrences only, that number would have increased to 70%. Using serial 7-day ECG, 113 Holter with over 18,900 hours of ECG recording were acquired. After 6 months the percentage of patients classified as free from AF was 50%. Of the patients with recurrences, 30–40% were completely asymptomatic. The percentage of asymptomatic AF episodes stepwise increased from 11% prior ablation to 53% 6 months after. Conclusions: The success rate in terms of freedom from AF was 70% on a symptom-only-based follow-up; using serial 7-day Holter it decreased to 50% and on transtelephonic monitoring to 45%, respectively. Transtelephonic ECG and serial 7-day Holter were equally effective to objectively determine long-term success and to detect asymptomatic patients.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    350 Main Street , Malden , MA 02148-5018 , USA and 9600 Garsington Road , Oxford OX4 2DQ , UK . : Blackwell Science Inc
    Pacing and clinical electrophysiology 28 (2005), S. 0 
    ISSN: 1540-8159
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: Introduction: Cardiac resynchronization therapy (CRT) using left ventricular (LV) pacing from the coronary sinus tributary is increasingly and frequently used in patients with severe congestive heart failure. The present study investigates LV lead performance in different anatomic locations. Methods: The LV pacing site was defined by bi-plane fluoroscopy. In the left anterior oblique view, the coronary sinus is encircling the mitral ring with the tributaries radiating out like the hands of a watch. Using this clockwise method, Group A had an LV pacing site before 3 o'clock and Group B at or after 3 o'clock. In right anterior oblique view, the LV was divided into three segments: basal, mid-ventricular, and apical. Results: LV lead implantation was successful in all of 120 consecutive patients. Mean follow-up was 16.7 months. Implantation time decreased from mean 190 to 80 minutes during the period (P = 0.01). The mean LV lead stimulation threshold increased initially and stabilized afterwards. The threshold measured at last follow-up was higher than at implantation (2.3 vs 2.7 μJ, P = 0.04). Useful venograms were obtained in 94 patients. No significant difference in thresholds was observed between Groups A and B. Phrenic nerve stimulation was most commonly seen in Group B (8/70 vs 1/24, P = 0.001). Conclusion: Implantation of an LV lead for CRT is possible in patients with congestive heart failure and associated with an acceptable low complication rate. LV lead implantation is associated with a learning curve. At mid-term follow-up, LV lead performance is stable and unrelated to the LV implantation site.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 3
    Publication Date: 2017-11-07
    Description: Background:The DANISH study (Danish Study to Assess the Efficacy of ICDs [Implantable Cardioverter Defibrillators] in Patients With Non-Ischemic Systolic Heart Failure on Mortality) did not demonstrate an overall effect on all-cause mortality with ICD implantation. However, the prespecified subgroup analysis suggested a possible age-dependent association between ICD implantation and mortality with survival benefit seen only in the youngest patients. The nature of this relationship between age and outcome of a primary prevention ICD in patients with nonischemic systolic heart failure warrants further investigation.Methods:All 1116 patients from the DANISH study were included in this prespecified subgroup analysis. We assessed the relationship between ICD implantation and mortality by age, and an optimal age cutoff was estimated nonparametrically with selection impact curves. Modes of death were divided into sudden cardiac death and nonsudden death and compared between patients younger and older than this age cutoff with the use of χ2 analysis.Results:Median age of the study population was 63 years (range, 21–84 years). There was a linearly decreasing relationship between ICD and mortality with age (hazard ratio [HR], 1.03; 95% confidence interval [CI], 1.003–1.06; P=0.03). An optimal age cutoff for ICD implantation was present at ≤70 years. There was an association between reduced all-cause mortality and ICD in patients ≤70 years of age (HR, 0.70; 95% CI, 0.51–0.96; P=0.03) but not in patients 〉70 years of age (HR, 1.05; 95% CI, 0.68–1.62; P=0.84). For patients ≤70 years old, the sudden cardiac death rate was 1.8 (95% CI, 1.3–2.5) and nonsudden death rate was 2.7 (95% CI, 2.1–3.5) events per 100 patient-years, whereas for patients 〉70 years old, the sudden cardiac death rate was 1.6 (95% CI, 0.8–3.2) and nonsudden death rate was 5.4 (95% CI, 3.7–7.8) events per 100 patient-years. This difference in modes of death between the 2 age groups was statistically significant (P=0.01).Conclusions:In patients with systolic heart failure not caused by ischemic heart disease, the association between the ICD and survival decreased linearly with increasing age. In this study population, an age cutoff for ICD implantation at ≤70 years yielded the highest survival for the population as a whole.Clinical Trial Registration:URL: https://www.clinicaltrials.gov. Unique identifier: NCT00542945.
    Keywords: Sudden Cardiac Death, Cardiomyopathy, Heart Failure
    Electronic ISSN: 1524-4539
    Topics: Medicine
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...