GLORIA

GEOMAR Library Ocean Research Information Access

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Acta Physica Sinica, Chinese Physical Society and Institute of Physics, Chinese Academy of Sciences  (32)
  • 1
    Online Resource
    Online Resource
    Acta Physica Sinica, Chinese Physical Society and Institute of Physics, Chinese Academy of Sciences ; 2021
    In:  Acta Physica Sinica Vol. 70, No. 8 ( 2021), p. 082901-
    In: Acta Physica Sinica, Acta Physica Sinica, Chinese Physical Society and Institute of Physics, Chinese Academy of Sciences, Vol. 70, No. 8 ( 2021), p. 082901-
    Abstract: At present, there exist few proton-beam terminals for the detector calibration in the world. Meanwhile, most of these terminals provide monoenergetic protons. Back-n white neutron source from China Spallation Neutron Source(CSNS) was put into operation in 2018. Based on the white neutron flux ranging from 0.5 eV to 200 MeV from the CSNS Back-n white neutron source, continuous-energy protons involved in a wide energy spectrum can be acquired from the 〈sup〉1〈/sup〉H(n, el) reaction. Adopting this method, a new research platform for researches such as proton calibration is realized at CSNS. As hydrogen exists as gas at normal temperature and pressure, in the selecting of the proton-converting target, the hydrogen-rich compounds are preferential considered. Considering the reaction cross sections of the 〈sup〉1〈/sup〉H(n, el), 〈sup〉12〈/sup〉C(n, p)〈sup〉12〈/sup〉B, 〈sup〉12〈/sup〉C(n, d)〈sup〉11〈/sup〉B, 〈sup〉12〈/sup〉C(n, t)〈sup〉10〈/sup〉B, 〈sup〉12〈/sup〉C(n, 〈sup〉3〈/sup〉He)〈sup〉10〈/sup〉Be, 〈sup〉12〈/sup〉C(n, α)〈sup〉9〈/sup〉Be and 〈sup〉1〈/sup〉H(n, γ)〈sup〉2〈/sup〉H, polyethylene and polypropylene are suitable for serving as targets in this research. Based on a 3U PXIe, digitizers with 1 GSps sampling rate and 12 bit resolution are utilized to digitize and record the output signals of telescopes. The time and amplitude information of each signal are extracted from its recorded waveform. Proton fluxes can be calculated by using the neutron energy spectrum and the cross section of the 〈sup〉1〈/sup〉H(n, el) reaction. Using the γ-flash event as the starting time of the time-of-flight (TOF) and the time information of signal in detector as the stopping time, the kinematic energy of each secondary proton can be deduced from the TOF and the angle of the detector. A calibration experiment on three charged particle telescopes, with each telescope consisting of a silicon detector and a CsI(Tl) detector, is carried out on this research platform. The readout methods of the CsI(Tl) detectors in these three telescopes are different. In the calibration experiment, Δ〈i〉E-〈/i〉〈i〉E〈/i〉 two-dimensional spectra and amplitude-〈i〉E〈/i〉〈sub〉p〈/sub〉 two-dimensional spectra of these telescopes are obtained. Through comparing these particle identification spectra, the SiPM is chosen as the signal readout method for CsI(Tl) detectors in the charged particle telescopes. These researches provide experimental evidence for the construction of the charged particle telescope at Back-n, and also illustrate the feasibility of wide-energy spectrum proton calibration based on the Back-n white neutron source.
    Type of Medium: Online Resource
    ISSN: 1000-3290 , 1000-3290
    Language: Unknown
    Publisher: Acta Physica Sinica, Chinese Physical Society and Institute of Physics, Chinese Academy of Sciences
    Publication Date: 2021
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 2
    Online Resource
    Online Resource
    Acta Physica Sinica, Chinese Physical Society and Institute of Physics, Chinese Academy of Sciences ; 2021
    In:  Acta Physica Sinica Vol. 70, No. 22 ( 2021), p. 222801-
    In: Acta Physica Sinica, Acta Physica Sinica, Chinese Physical Society and Institute of Physics, Chinese Academy of Sciences, Vol. 70, No. 22 ( 2021), p. 222801-
    Abstract: The data of neutron capture cross section are very important for the research of nuclear astrophysics, advanced nuclear energy development. Owing to the limitation of neutron source and detector, the experimental data of neutron capture cross section in an energy range of 1 eV–10 keV were almost blank in China. The first Chinese gamma-ray total absorption facility has been constructed in the key laboratory of nuclear data at China institute of atomic energy, which consists of 40 BaF〈sub〉2〈/sub〉 detector units. The BaF〈sub〉2〈/sub〉 crystal shell with a thickness of 15 cm and an inner radius of 10 cm covers 95.2% of the solid angle. On-line measurement method of neutron capture reaction cross section is established on the back-streaming white neutron source of China spallation neutron source by using the upgraded facility. The cross section of 〈sup〉197〈/sup〉Au neutron capture reaction is measured for the first time under the experimental condition of irregular 30 mm neutron beam spot. The measured position of resonance peak is well consistent with the relevant data of ENDF evaluation database, which verifies the reliability of the measurement device and measurement technology, and thus laying the foundation for the acquisition of high precision cross section in future.
    Type of Medium: Online Resource
    ISSN: 1000-3290 , 1000-3290
    Language: Unknown
    Publisher: Acta Physica Sinica, Chinese Physical Society and Institute of Physics, Chinese Academy of Sciences
    Publication Date: 2021
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 3
    Online Resource
    Online Resource
    Acta Physica Sinica, Chinese Physical Society and Institute of Physics, Chinese Academy of Sciences ; 2024
    In:  Acta Physica Sinica Vol. 73, No. 7 ( 2024), p. 072801-
    In: Acta Physica Sinica, Acta Physica Sinica, Chinese Physical Society and Institute of Physics, Chinese Academy of Sciences, Vol. 73, No. 7 ( 2024), p. 072801-
    Abstract: Neutron capture reaction is one of the neutron reactions and plays an important role in using reactor control rods and shell materials, designing nuclear device structures, and studying nuclear astrophysics S processes and element origins. The 4π BaF 〈 sub 〉 2 〈 /sub 〉 detection device has advantages such as high time resolution, low neutron sensitivity, and high detection efficiency, thus making it suitable for measuring neutron radiation capture reaction cross-section data. In order to fill the gap in our neutron capture reaction data in the keV energy range and improve their accuracy, the Key Laboratory of Nuclear Data at the Chinese Institute of Atomic Energy (CIAE) has established a Gamma Total Absorption Facility (GTAF), which consists of 28 hexagonal BaF 〈 sub 〉 2 〈 /sub 〉 crystals and 12 pentagonal BaF 〈 sub 〉 2 〈 /sub 〉 crystals to form a spherical shell with an external diameter of 25 cm and an internal diameter of 10 cm, covering 95.2% of the solid angles. The Back-n beam line of the Chinese Spallation Neutron Source (CSNS) is a back-streaming white beam line that covers neutron energy ranging from a few eV to several hundred MeV, making it suitable for measuring neutron capture cross-sections. The reaction cross-section data of 〈 sup 〉 197 〈 /sup 〉 Au is measured by using GTAF on the Back-n beam line. The measurement data are preliminarily background deducted through energy screening, PSD method, and crystal multiplicity screening. Subsequently, the background is analyzed and deducted based on the measurement data of 〈 sup 〉 nat 〈 /sup 〉 C and empty samples, and the yield of 〈 sup 〉 197 〈 /sup 〉 Au capture reaction is obtained. Resonance parameters are a set of parameters extracted from experimental data to describe the resonance curve, which can eliminate the influence of experimental conditions on resonance data and are more important than the cross-section obtained from experiments. The resonance energy, neutron resonance width, and gamma resonance width parameters of 〈 sup 〉 197 〈 /sup 〉 Au at 1–100 eV are fitted by using the SAMMY program. From the comparison between the resonance curves obtained from experimental measurements and the resonance parameters obtained from fitting with the ENDF/B-VIII.0 database, it can follow that the experimental measurement results are in good agreement with the database, nevertheless, there exist some differences in the resonance parameter, which may be due to the GTAF energy resolution, Back-n neutron spectrum measurement accuracy, and the experimental background deduction method. Our next work is to identify the sources of difference.
    Type of Medium: Online Resource
    ISSN: 1000-3290 , 1000-3290
    Language: Unknown
    Publisher: Acta Physica Sinica, Chinese Physical Society and Institute of Physics, Chinese Academy of Sciences
    Publication Date: 2024
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 4
    Online Resource
    Online Resource
    Acta Physica Sinica, Chinese Physical Society and Institute of Physics, Chinese Academy of Sciences ; 2020
    In:  Acta Physica Sinica Vol. 69, No. 17 ( 2020), p. 172901-
    In: Acta Physica Sinica, Acta Physica Sinica, Chinese Physical Society and Institute of Physics, Chinese Academy of Sciences, Vol. 69, No. 17 ( 2020), p. 172901-
    Abstract: The back-streaming neutron beam line (Back-n) was built in the beginning of 2018, which is part of the China Spallation Neutron Source (CSNS). The Back-n is the first white neutron beam line in China, and its main application is for nuclear data measurement. For most of neutron-induced nuclear reaction measurements based on white neutron facilities, the beam of gamma rays accompanied with neutron beam is one of the most important experimental backgrounds. The back streaming neutron beam is transported directly from the spallation target to the experimental station without any moderator or shielding, the flux of the in-beam gamma rays in the experimental station is much larger than those of these facilities with neutron moderator and shielding. Therefore, it is necessary to consider the influence of in-beam gamma rays on the experimental results. Studies of the in-beam gamma rays are carried out at the back-n. Monte-Carlo simulation is employed to obtain the energy distribution and the time structure of the in-beam gamma rays. According to the simulation results, when the neutron flight time is longer than 1.0 μs the energy distribution of the in-beam gamma rays does not vary with flight time. Therefore, the time structure of these gamma rays can be measured without the correction of the detection efficiency. In this work, the time structure of the in-beam gamma rays in the low neutron energy region is measured by both direct and indirect methods. In the direct measurement, a 〈sup〉6〈/sup〉Li loaded ZnS(Ag) scintillator is located on the neutron beam line and the time of flight method is used to determine the time structure of neutrons and gamma rays. The gamma rays are separated from neutrons with pulse-shape discrimination. The black filter method is used to verify the particle discrimination results. In the indirect measurement, the C〈sub〉6〈/sub〉D〈sub〉6〈/sub〉 scintillation detectors are used to measure the gamma rays scattered off a Pb sample on the way of the neutron beam. The time structure of the in-beam gamma rays is derived from that of the scattered gamma rays. The experimental results are in good agreement with the simulations with the time-of-flight between 12 μs and 2.0 ms. Besides, according to the simulation results, the intensity of the in-beam gamma rays is 1.21 × 10〈sup〉6〈/sup〉 s〈sup〉–1〈/sup〉·cm〈sup〉–2〈/sup〉 in the center of the experimental station 2 of Back-n, which is 76.5 m away from the spallation target of CSNS.
    Type of Medium: Online Resource
    ISSN: 1000-3290 , 1000-3290
    Language: Unknown
    Publisher: Acta Physica Sinica, Chinese Physical Society and Institute of Physics, Chinese Academy of Sciences
    Publication Date: 2020
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 5
    In: Acta Physica Sinica, Acta Physica Sinica, Chinese Physical Society and Institute of Physics, Chinese Academy of Sciences, Vol. 62, No. 19 ( 2013), p. 197204-
    Abstract: Highly efficient all fluorescent white organic light-emitting devices (WOLED) have been fabricated by means of sequential doping. Fluorescent materials PT-01, PT-86 and PT-05 serve as the yellow guest, blue guest and fluorescent host, respectively. The emission layer consists of a few repeating cells, which are made of sequentially evaporated host and guest layers. From the analyses of the singlet exciton distribution and the influences of the thickness of the host layer, PT-86 and PT-01 are evaporated at the proper locations in the emission layer (EML), yielding a high efficiency and stable all fluorescent WOLEDs. The maximum current efficiency of the WOLED is 11.2 cd/A. In addition, the emission color of this WOLED is fairly stable, consistent with the Commission International de L’Eclairage coordinates, only showing changes (±0.004,±0.005) when luminance increasing from 159 cd/m2 to 20590 cd/m2. The devices based on the method of sequential doping not only have the similar performance compared with that fabricated by co-evaporation doping, but also have higher repeatability, which makes them appropriate for mass-production.
    Type of Medium: Online Resource
    ISSN: 1000-3290 , 1000-3290
    Language: Unknown
    Publisher: Acta Physica Sinica, Chinese Physical Society and Institute of Physics, Chinese Academy of Sciences
    Publication Date: 2013
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 6
    In: Acta Physica Sinica, Acta Physica Sinica, Chinese Physical Society and Institute of Physics, Chinese Academy of Sciences, Vol. 58, No. 3 ( 2009), p. 1779-
    Abstract: Single-photon-counting imaging technology has been widely used in ultraweak bioluminescence, space environment detection and nuclear radiation detection. The structure and working principle of an ultraviolet single photon imaging system based on the microchannel plates and the wedge and strip anode are introduced. The gain characteristic of dark count of two and three microchannel plates is investigated under different voltages respectively. The experimental and fitted results show that the dark count pulse height distribution of microchannel plate has exponential distribution, and the dark count rate rises as the voltage increases. It is shown that the gain becomes more homogeneous as the voltage increases by measuring the pulse height distribution under different voltages. Then the effects of microchannel plate voltage and distance on system resolution with two microchannel plates are tested. It is revealed that the system resolution rises as the voltage of microchannel plate increases, and can be improved also by increasing the distance of microchannel plate properly.
    Type of Medium: Online Resource
    ISSN: 1000-3290 , 1000-3290
    Language: Unknown
    Publisher: Acta Physica Sinica, Chinese Physical Society and Institute of Physics, Chinese Academy of Sciences
    Publication Date: 2009
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 7
    In: Acta Physica Sinica, Acta Physica Sinica, Chinese Physical Society and Institute of Physics, Chinese Academy of Sciences, Vol. 55, No. 11 ( 2006), p. 5760-
    Abstract: In this paper we present an improved nuclear density model. We have found the nuclear effect parameters’ formula RAV(x,Q2) and RAS(x,Q2) for the valence quark distribution and sea quark distribution in the nucleus, in which we have used the relation between the nuclear density and the mean binding energy in nucleus. By using the model, we can well explain the experimental data of the of Drell-Yan process in P-A.
    Type of Medium: Online Resource
    ISSN: 1000-3290 , 1000-3290
    Language: Unknown
    Publisher: Acta Physica Sinica, Chinese Physical Society and Institute of Physics, Chinese Academy of Sciences
    Publication Date: 2006
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 8
    In: Acta Physica Sinica, Acta Physica Sinica, Chinese Physical Society and Institute of Physics, Chinese Academy of Sciences, Vol. 48, No. 1 ( 1999), p. 180-
    Abstract: Quantum wells of CdTe/CdZnTe were grown by molecular beam epitaxy. The highest order of satellite peak of the sample is 5 from XRD spectra and excition emission linewidth is about 4.8 nm at 77 K. It was shown that our samples are very good. The recombination dynamics of exciton in high-quality CdZnTe/CdTe multiquantum wells were investigated by means of time-resolved photoluminescence(PL) spectra with different excitation power at 77 K and photoluminescence spectra with different temperature. When weaker excitation was used, radiative recombination decay time of the exciton was reduced as the excitation intensity was decreased; the results indicate that the dominant mechanism may be the quenching of exciton emission by impurities and defects. The linewidth of the exciton emission becomes broader with increasing temperature, the linewidth at low temperature is only due to the well thickness, and the broadening linewidth at high temperature is contributed by the interactions among the exciton and LO and TO phonons and ionized donor impurities. The PL intensities are reduced with increasing temperature, which is mainly due to the thermal dissociation of excitons, i.e., the electrons or holes jump into the barriers from the wells by thermal excitations. The exciton emission from n=2 heavy hole exciton at 77 K has been observed, and the n=2 heavy hole exciton luminescence decay time is shorter than that from n=1. The investigation indicates that there is the exciton energy relaxation from the n=2 to n=1 heavy hole exciton state by phonons.
    Type of Medium: Online Resource
    ISSN: 1000-3290 , 1000-3290
    Language: Unknown
    Publisher: Acta Physica Sinica, Chinese Physical Society and Institute of Physics, Chinese Academy of Sciences
    Publication Date: 1999
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 9
    In: Acta Physica Sinica, Acta Physica Sinica, Chinese Physical Society and Institute of Physics, Chinese Academy of Sciences, Vol. 52, No. 7 ( 2003), p. 1797-
    Abstract: The carbon nitride films deposited by r.f. magnetron sputtering in pure N2 discharge were annealed in vacuum up to 900 ℃. The chemical composition and bonding structure of the films were studied using x-ray photoelectron spectroscopy, Fourier Transform Infrared. The effects of thermal annealing on the bonding structure and the electron field emission characteristics of CNx films wer e investigated. It is found that the sp2 bonds and N content in CNx films are closely related to the filed emission of CNx films. The results show that thermal annealing treatment causes a great loss of N content and a larger formation of sp2 bonds in CNx films, which would influence sign ificantly the field emission properties for the CNx films. The CNx films annealed at 750 ℃ show the optimal electron emission properties. Besides, the correlation between the chemical bonding structures and electron emission properties for the CNx films was also discussed.
    Type of Medium: Online Resource
    ISSN: 1000-3290 , 1000-3290
    Language: Unknown
    Publisher: Acta Physica Sinica, Chinese Physical Society and Institute of Physics, Chinese Academy of Sciences
    Publication Date: 2003
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 10
    In: Acta Physica Sinica, Acta Physica Sinica, Chinese Physical Society and Institute of Physics, Chinese Academy of Sciences, Vol. 61, No. 18 ( 2012), p. 184218-
    Abstract: Compared with the beam of conventional relativistic klystron, each beam of the multi-beam relativistic klystron has a low perveance and low space charge force, but it has a high conversion efficiency of beam-wave. According to these requirements, in this paper we investigate the generation and transmission of fan-shaped multi-beam intense relativistic electron beams by the experiment and the simulation with using the three-dimensional software, and analyse the electrostatic field distribution of the cathode end and the influence on the generation of the electron beams by establishing a three-dimensional model of electron gun. The emission currents by the particle-in-cell simulation, then the beam spot pictures of electron beam transmission in a hollow drift tube and multiple fan-shaped hole drift tube by the particle tracking solver are obtained. The theoretical analysis and explanation with the aid of the sheet beam theory are presented. The simulation and experimental results show that the beams rotate not only around their own center, but also around the center of the system in the transmission process of the electron beams in the hollow drift tube. Thus we can increase the transmission efficiency by rotating multiple fan-shaped hole drift tube to align the beams.
    Type of Medium: Online Resource
    ISSN: 1000-3290 , 1000-3290
    Language: Unknown
    Publisher: Acta Physica Sinica, Chinese Physical Society and Institute of Physics, Chinese Academy of Sciences
    Publication Date: 2012
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...