The geometrical parameters of injection devices are shown to have almost no effect on the resulting two-phase flow, while they influence the pressure drop owing to its formation. The predominant hydrodynamic parameter is the ratio of the mean superficial velocities. A simplified analysis leads to good agreement with experimental results. The different causes of pressure drops are quantified.