GLORIA

GEOMAR Library Ocean Research Information Access

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 1980-1984  (2)
Document type
Publisher
Years
Year
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    European journal of clinical pharmacology 22 (1982), S. 129-135 
    ISSN: 1432-1041
    Keywords: lidocaine overdose ; lidocaine kinetics ; extracorporeal pump ; hepatic clearance ; cardiac output
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Medicine
    Notes: Summary Accidental bolus administration of lidocaine ranging in dosages from 1000mg to 2000mg has caused death in humans. Because lidocaine clearance depends upon hepatic blood flow, drug clearance in a hypotensive overdosed patient is poor so that a drug overdose is likely to be irreversible. Traditional approaches to drug removal include hemodialysis and charcoal hemoperfusion. Neither treatment would be effective for lidocaine overdose because the drug is a myocardial depressant and because the clearance rates of these techniques are 100–200ml/min. Hepatic clearance of lidocaine is 1000ml/min in a human with normal cardiac output. We have tested a new concept for removal of high clearance drugs that are associated with myocardial depression. Cardiac bypass support was used in a dog experiment to demonstrate that restoration of cardiac output could restore high clearance of lidocaine. Sixteen anesthetized dogs were given 30mg/kg boluses of lidocaine. In one group of eight dogs, toxicity was treated with antiarrhythmic drugs, pressor drugs and cardioversion. Six out of eight of these animals died within 30min after lidocaine infusion. In the second group of eight dogs, an extracorporeal bypass pump was used for 90min after the lidocaine injection. None of these assisted animals died. Drug clearance in dogs treated with the extracorporeal pump was compared to drug clearance in eight dogs that received non-toxic lidocaine doses of 3mg/kg. Drug clearance was 39.75±4.16ml/kg/min in the overdosed animals compared to 38.29±8.6 ml/kg/min in the non-toxic animals. Thus, drug clearance was normal in dogs treated with the extracorporeal pump. These experiments suggest that short-term support of the circulation with an extracorporeal pump could theoretically be effective in reducing patient mortality from acute massive lidocaine overdose.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Hyperfine interactions 16 (1983), S. 713-716 
    ISSN: 1572-9540
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract Mössbauer spectra of161Dy in DyCo2 Si2 were taken between 4.2K and 78K. The tetragonal intermetallic has a Neel temperature of TN=21K. Up to 25K spectra are characterized by extremely slow electronic relaxation, precluding the usual collapse of hyperfine splitting on approaching TN. Between TN and 78K relaxation spectra are seen. The most unusual feature is a slow, steady decrease of Bhf and e2qQ with temperature. It is suggested that this arises from changes in the wave function of the electronic ground state by influences of the molecular and the crystalline electric fields.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...