The vestibulo-ocular reflex was studied via off-vertical axis rotation (OVAR) in the dark. The axis of the turntable could be tilted from vertical by up to 30°. Eye movements were measured with electro-oculography. Results from healthy asymptomatic subjects indicated that 1) a reliable otolith-induced response could be obtained during constant velocity OVAR using a velocity of 60°/s with a tilt of 30°; 2) constant velocity OVAR rotation was nausea-producing and, especially if subjects were rotated in the dark about an earth-vertical axis prior to being tilted, disorienting; and 3) sinusoidal OVAR produced minimal nausea; the eye movement response appeared to be the result of a combination of semicircular canal and otolith components. We conclude that OVAR has the potential of becoming a useful method for clinically assessing both the otolith-ocular reflex and semicircular canal—otolith interaction.