GLORIA

GEOMAR Library Ocean Research Information Access

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Articles  (7)
  • 1990-1994  (7)
  • 1
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    International journal of dermatology 29 (1990), S. 0 
    ISSN: 1365-4632
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    Dental traumatology 6 (1990), S. 0 
    ISSN: 1600-0595
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: Abstract The cumulative survival rate (retention of both cusps) and the fracture pattern of 1639 endodontically treated posterior teeth were assessed in a retrospective study. All teeth had an MO/DO or an MOD cavity restored with amalgam without cuspal overlays. The 20-year survival rate of teeth with an MO/ DO cavity was markedly higher than that of teeth with an MOD cavity. The lowest survival rate was found for the upper premolars with an MOD cavity: 28% of these teeth fractured within 3 years after endodontic therapy, 57% were lost after 10 years, and 73% after 20 years. Generally, the cusp most prone to fracture was the lingual one, and lingual fractures caused significantly more damage to the periodontal tissues than did facial or total crown fractures. The severity of periodontal damage increased with posterior location of the tooth. By far the most serious failures, irrespective of the cavity type, were found for the upper second molar, as 10 of 29 fractures led to extraction. It is concluded that amalgam, especially in MOD cavities, is an unacceptable material for restoration of endodontically treated posterior teeth if used without cuspal overlays.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    Dental traumatology 6 (1990), S. 0 
    ISSN: 1600-0595
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: Abstract The cumulative survival rate of 190 endodontically treated posterior teeth were assessed in a retrospective study; all teeth had an MO/DO or an MOD cavity restored with a composite resin without cuspal overlays after previous acid-etching of the enamel. In contrast to our previous study on endontically treated posterior teeth restored with amalgam, the survival rate of the MOD resin-restored teeth was equal to that of MO/DO teeth. Teeth restored with a light-activated resin had a much lower survival rate than teeth restored with a chemically-activated material, the cause presumably being that the light-activated resins were insufficiently irradiated. Nearly 25% of the teeth had been restored with a microfilled resin for anterior use and these teeth had a lower survival rate than had teeth restored with a macrofilled or hybrid resin. It was also found that a beveling technique did not decrease the fracture rate while the use of an intermediate layer of low-viscosity resin resulted in a significant improvement.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 1600-0714
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: Histologic examination of muscle biopsies and functional examination comprising electromyography and force measurements in a 19-yr-old boy with muscular dystrophy showed different wasting patterns of mandibular elevator and depressor muscles. Pronounced histopathologic changes were present in the masseter muscle, whereas pathologic findings in the anterior digastric muscle were limited to increased number of cells in slightly enlarged interfiber connective tissue. The masticatory pattern was distorted, and strength of mandibular elevator muscles was less than one third of the norm, whereas depressor strength corresponded more to reference values. This difference of muscular wasting might be caused by protective enzymes in the digastric muscle and/or functionally induced damage of the masseter. As affection from muscular dystrophy may vary greatly between the masticatory muscles, structural and functional examination should be used routinely to clarify prognosis before initiation of treatment procedures.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Copenhagen : Munksgaard International Publishers
    Clinical oral implants research 3 (1992), S. 0 
    ISSN: 1600-0501
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: The aim of the present study was to compare the anchorage of TiO2-blasted screw and cylindrical implants with conventionally used machine-produced screw and cylindrical implants inserted immediately in extraction sockets on dogs. 6 adult mongrel dogs had 3rd and 4th mandibular premolars extracted bilaterally and 24 commercial pure titanium implants were placed immediately in extraction sockets and covered with mucoperiosteum. Each dog had inserted 4 implants: 1 screw implant and 1 cylindrical implant blasted with titanium-dioxide-particles; 1 screw implant and 1 cylindrical implant with machine-produced (m.p.) surface (controls). After a healing period of 12 weeks, 16 implants from 4 animals were used for removal torque test, which demonstrated that significantly higher removal torque force was needed to unscrew the implants blasted with titanium-dioxide-particles, than the normal m.p. implants. The medians for the TiO2-blasted screw and cylindrical implants were 〉 150 Ncm and 10.5 Ncm, respectively, while the values for the m.p. implants were 60 Ncm and 35 Ncm, respectively. The SEM investigation demonstrated a high irregularity of the TiO2-blasted surface compared to the machined surface. The R, and R, values for surface roughness were higher for the TiO2-blasted implants than for the normal m.p. implants. Histomorphometrically, the arithmetic mean of the direct bone-implant contact fraction was 69%. There was no significant difference in direct bone-implant contact length fraction between TiO2-blasted implants and the control implants. The implants blasted with titanium-dioxide-particles in this study showed a better anchorage than implants with a machine-produced surface. The screw implants showed a better anchorage than the cylindrical implants.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Copenhagen : Munksgaard International Publishers
    Clinical oral implants research 2 (1991), S. 0 
    ISSN: 1600-0501
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: A qualitative and quantitative histological study of the initial healing response adjacent to 24 submerged and non-submerged implants placed in the lower jaws of 6 monkeys is presented. The histomorphometric analysis showed no significant differences in mineralized bone-implant contact length between submerged and non-loaded non-submerged titanium implants. The infrabony defects around some of the implants on the radiographs were significantly correlated to the histological measurements. Qualitatively, a greater number of gingival inflammation cells and a longer junctional epithelium were seen adjacent to non-submerged implants without oral hygiene than were seen adjacent to non-submerged implants with oral hygiene in the initial healing period.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Chichester, West Sussex : Wiley-Blackwell
    Mathematical Methods in the Applied Sciences 13 (1990), S. 23-30 
    ISSN: 0170-4214
    Keywords: Mathematics and Statistics ; Applied Mathematics
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Mathematics
    Notes: Poiseuille-type flow in an open channel is studied taking surface tension and wall adhesion into account. A proof is presented of the existence of a solution under certain conditions.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...